• Title/Summary/Keyword: free Tc-99m pertechnetate

Search Result 5, Processing Time 0.016 seconds

Bowel Activity Caused by Free Tc-99m Pertechnetate Mimicking Urine Leaks during Tc-99m $MAG_{3}$ Renal Scintigraphy (Tc-99m MAG3 신장 스캔시 뇨 누출과 유사한 유리 Tc-99m 과산화테크네슘에 의한 장관내 방사능)

  • Lim, Seok-Tae;Kim, Min-Woo;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.135-136
    • /
    • 2003
  • A 43-year-old woman with diabetic nephropathy underwent a Tc-99m MAG3 renal scintigraphy for the evaluation of renal function. Posterior images at 60 minutes demonstrated a migration of radiotracer activity beyond the lower pole of the left kidney, which might be incorrectly interpreted as urine leaks. However, the increased activities were moving along the bowel lumens over time. Another ring-like radioactivity was also seen in the suprasplenic region, and increased with time. These radioactivities were in the gastric fundus and gastrointestinal tract and caused by free Tc-99m pertechnetate.

Simultaneous Visualization of the Sublingual Thyroid and Lactating Breasts with Tc-99m Pertechnetate Scintigraphy (설하갑상선과 수유중 유방이 Tc-99m Pertechnetate 스캔에 동시에 관찰된 증례)

  • Seo, Ji-Hyoung;Seong, Young-Ok;Bae, Jin-Ho;Jeong, Shin-Young;Ahn, Byeong-Cheol;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.489-490
    • /
    • 2005
  • Purpose: The thyroglossal duct runs from the base of the tongue to the thyroid. Rarely the thyroid completely fails to migrate and results in ectopic thyroid tissue, which can be demonstrated scintigraphically. A 31-year old female patient was referred for thyroid scintigraphy due to protruding mass at the base of the tongue. She was mildly hypothyroid. Te-99m pertechnetate thyroid scan was performed to rule out ectopic thyroid gland. There showed a focal area of intense tracer uptake in sublingual area, suggesting the sublingual thyroid. In addition there noted diffusely increased tracer uptake in both breasts. The patient delivered a baby 6 months prior to the scan and was on breast-feeding. Free Tc-99m pertechnetate physiologically secrets into the salivary glands, the stomach, the gastrointestinal tract, the genitourinary tract and the mammary glands and sodium-iodide symporter plays a role in the accumulation of free Tc-99m pertechnetate. We report simultaneous visualization of lactating breasts and ectopic thyroid gland in the base of the tongue.

A Study on the Quality Improvement of Brain Perfusion SPECT Image (뇌혈류 단일광자방출단층촬영 영상 품질 향상에 대한 연구)

  • Kil, Sang-Hyeong;Lim, Yung-Hyun;Park, Gwang-Yeol;Cho, Seong-Mook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.13-19
    • /
    • 2019
  • Purpose Tc-99m HMPAO is widely used radiopharmaceutical for brain perfusion SPECT. Tc-99m HMPAO is chemically unstable and is liable to show deterioration of labeling efficiency due to high incidence of secondary Tc-99m HMPAO complex, free pertechnetate and reduced-hydrolyzed Tc-99m. In this study, we investigated whether sialogogues administration could reduce the impurities of Tc-99m HMPAO. Materials and Methods In thirty subjects(20 male and 10 female, age range 19~89 years, mean age $60.7{\pm}14.5years$), brain perfusion SPECT were performed at basal and citric acid stimulation states consecutively after injection of 555 MBq of Tc-99m HMPAO. In the salivary glands, the uptake coefficient was calculated using Siemens processing program. Statistical comparison between before and after the citric acid stimulation performed paired t-test. P value less than 0.05 was regarded as statistically significant. Results Salivary glands uptake was $12900{\pm}3101$ counts in basal and $10677{\pm}2742$ counts in citric acid stimulation states. Unnecessary impurities in the body is much decreased after citric acid administration(t=10.78, P<0.05). The image quality was much improved after administration of citric acid and the regional cerebral perfusion was clearly from demarcated the background. Conclusion The impurity is distributed throughout the body particularly in the salivary glands and nasal mucosa when Tc-99m HMPAO brain perfusion SPECT is performed. If this impurities is not removed, the quality of the image may deteriorate, resulting in errors in visual evaluation. The use of sialogogues could be helpful for decreasing unnecessary impurities in the body.

Evaluation of Extraosseous Abnormalities Detected in Bone Scan ($^{99m}Tc-Methylene$ Diphosphonate (MDP)골(骨)스캔에서 골격외(骨格外) 섭취(攝取) 및 신요로계(腎尿路系) 이상소견(異常所見)에 관(關)한 연구(硏究))

  • Rhim, Sang-Moo;Park, Ran-Jae;Kim, Byung-Tae;Lee, Myung-Chul;Cho, Bo-Yeon;Lee, Hong-Kyu;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 1982
  • The purpose of the present study is to evaluate the clinical and diagnostic significance of incidental findings of renal and urinary tract abnormalities, and extraosseous uptake of bone scans. The authors analyzed bone scans using $^{99m}Tc-MDP$(methylene diphosphonate) in 1238 cases of bone disease from April, 1979 to March, 1981. The results obtained were as follows. 1. Total extraosseous abnormalities were 112 cases (9%), which include 64 cases (5%) of renal and urinary tract abnormalities and 48 case(4%) of other extraosseous uptakes. 2. Renal and urinary tract abnormalities were 32 cases(50%) of obstruction, 14 cases(22%) of nonvisualization, 6 cases of space occupying lesion in kidney, 8 cases of kidney displacement and 4 cases of urinary bladder deformities. 3. Other extraosseous uptakes were 16 cases (33%) of body fluid collection, 15 cases of tumor uptake, 9 cases of free pertechnetate uptake and 8 others.

  • PDF

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF