• 제목/요약/키워드: framed buildings

검색결과 116건 처리시간 0.023초

Evaluation of Bending Creep Performance of Laminated Veneer Lumber (LVL) Formwork for the Design of Timber Concrete Composite (TCC) Structures

  • Hyun Bae KIM;Takuyuki YOSHIOKA;Kazuhiko FUJITA;Jun ITO;Haruka NOHARA;Keiji NOHARA;Toshiki NARITA;Wonwoo LEE;Arata HOSOKAWA;Tetsuiji TANAKA
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권4호
    • /
    • pp.375-382
    • /
    • 2024
  • The study focuses on evaluating the bending creep performance of laminated veneer lumber (LVL) formwork in timber concrete composite (TCC) structures. Timber-framed construction is highlighted for its environmental benefits and seismic resistance, but limitations such as poor tensile strength and brittle failure in bending hinder its use in high-rise buildings. Wood-concrete hybrid structures, particularly those using reinforced concrete slabs with TCC floors, emerge as a potential solution. The research aims to understand the time-dependent behavior of TCC components, considering factors like wood and concrete shrinkage and connection creep. The experiment was conducted in western Japan on the TCC floor designed for use in the Kama-city Inatsuki-higashi compulsory education school. The LVL formwork, measuring 9,000 mm by 900 mm, and concrete is loaded onto it for testing. The creep test periods are examined using concrete loading. It employs a comprehensive creep analysis, adhering to Japanese standards, involving deflection measurements and regression analysis to estimate the creep coefficient. Results indicate substantial deformation after shoring removal, suggesting potential reinforcement needs. The study recommends extending test periods for improved accuracy and recognizing regional climate impacts. Overall, the research provides valuable insights into the potential of LVL formwork in TCC structures, emphasizing safety considerations and paving the way for further experimentation under varied conditions to validate structural integrity.

Vibration analysis and FE model updating of lightweight steel floors in full-scale prefabricated building

  • Petrovic-Kotur, Smiljana P.;Pavic, Aleksandar P.
    • Structural Engineering and Mechanics
    • /
    • 제58권2호
    • /
    • pp.277-300
    • /
    • 2016
  • Cold-formed steel (CFS) sections are becoming an increasingly popular solution for constructing floors in residential, healthcare and education buildings. Their reduced weight, however, makes them prone to excessive vibrations, increasing the need for accurate prediction of CFS floor modal properties. By combining experimental modal analysis of a full-scale CFS framed building and its floors and their numerical finite element (FE) modelling this paper demonstrates that the existing methods (based on the best engineering judgement) for predicting CFS floor modal properties are unreliable. They can yield over 40% difference between the predicted and measured natural frequencies for important modes of vibration. This is because the methods were adopted from other floor types (e.g., timber or standard steel-concrete composite floors) and do not take into account specific features of CFS floors. Using the adjusted and then updated FE model, featuring semi-rigid connections led to markedly improved results. The first four measured and calculated CFS floor natural frequencies matched exactly and all relevant modal assurance criterion (MAC) values were above 90%. The introduction of flexible supports and more realistic modelling of the floor boundary conditions, as well as non-structural $fa{\c{c}}ade$ walls, proved to be crucial in the development of the new more successful modelling strategy. The process used to develop 10 identified and experimentally verified FE modelling parameters is based on published information and parameter adjustment resulting from FE model updating. This can be utilised for future design of similar lightweight steel floors in prefabricated buildings when checking their vibration serviceability, likely to be their governing design criterion.

한국 주심포식건축의 처마구조에 관한 연구 (A Study on the Eaves Structure of Korean Jusimpo-type Architecture)

  • 양재영
    • 건축역사연구
    • /
    • 제25권3호
    • /
    • pp.23-35
    • /
    • 2016
  • The purpose of this study is to classify types of the eaves structure of buildings with the Jusimpo-type structure and to analyze the characteristics of each eaves structure. For this objective, forty buildings were selected and investigated. The results of analysis are summarized as follows. First, the main members of framework which handle a load burden on the long-rafter(長椽) are classified as the Jusim-dori(柱心道里) and the Oemok-dori(外目道里). Based on the method of handling a load, the eaves structure is classified into three types; the Jusim-processing-type(柱心中心形), the Oemok-processing-type(外目中 心形), and the Oemok-processing-variant-type(外目中心變異形). The Jusim-processing-type is the set where the internal length of a long-rafter is longer than the length of the eaves on the basis of the center of a column. The Oemok-processing-type is the set where the external length of a long-rafter is longer than the internal length of it. And the Oemok-processing-variant-type is the set where the internal length of a long-rafter is longer than the external length of it, but it is shorter than the length of the eaves which includes the extruded length of a Buyeon(浮椽). Second, the Jusim-processing-type had been generally adopted in the Jusimpo-type structure of the Goryeo Dynasty. But since the 17th century, the Oemok-processing-type had the highest application rate. Third, the change from the Jusimdori-processing-structure to the Oemokdori-processing-structure means that the long-rafter is moved to the direction of outside of the building, and thus the Jung-dori(中道里) is gradually moved to the column center. And, the change of the eaves with the Jusimpo-type structure was not a process for increasing the length of the eaves but a process for adopting the advantages of the Dapo-type structure by changing the arrangement of purlin. Fourth, the change from the Jusimpo-type structure to the Dapo-type structure could be understood as a process for moving the main point for handling a load from the Jusim-dori to the Oemok-dori.

중력전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진 성능 평가 (Seismic Performance of Reinforced Concrete Flat Plate Frames according to Gravity Shear Ratio)

  • 황보진;한상환;박영미
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.3-10
    • /
    • 2010
  • 이 연구에서는 중력 전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진성능을 평가하였다. 이를 위하여, 이 연구에서는 3층, 7층 골조를 중력하중만 고려하여 설계하고, 대상 건물에 대한 비선형 정적 푸쉬 오버 해석과 비선형 동적 해석을 수행하였다. 그리고 이 연구는 그 비선형 해석에서 중력 전단비의 차이에 따른 뚫림 전단과 파괴 메커니즘을 예측할 수 있도록 제안한 슬래브-기둥 접합부 모델을 사용하였다. 이 연구 결과에 따르면 중력 전단비가 골조의 내진성능에 큰 영향을 미치는 것으로 나타났다. 특히 중력 전단비가 커짐에 따라 골조 접합부의 파괴가 취성적인 파괴를 나타내어 내진 성능이 떨어지는 것으로 나타났다.

The First Skyscraper Revisited

  • Ali, Mir M.;Moon, Kyoung Sun
    • 국제초고층학회논문집
    • /
    • 제11권1호
    • /
    • pp.1-14
    • /
    • 2022
  • Debates on what is the first skyscraper have been ongoing from time to time since the construction of the Home Insurance Building in Chicago in 1885, which is generally recognized as the first built skyscraper. This paper attempts to verify this assertion through a detailed investigation after identifying the criteria that characterize a skyscraper. By considering and examining several competing buildings for the title of "first skyscraper" in terms of their levels of satisfying these criteria, the paper reconfirms that the Home Insurance Building in Chicago indeed qualifies as the first skyscraper and is the harbinger of future skyscrapers. By introducing technological and associated architectural innovations in this pioneering building, its designer William Le Baron Jenney paved the way for the construction of future skyscrapers. In traditional construction, heavy masonry walls especially at lower levels did not allow large window openings in exterior walls that would permit ample daylight. For the Home Insurance Building, originally built with 10 stories, Jenney created a metal-framed skeletal structure that carried the building's loads, making the building lighter and allowed for large windows permitting ample natural light to the building's interior. The exterior iron columns were encased in relatively small masonry piers mainly for fireproofing, weather-protection and façade aesthetics. Relying on the structural framing on the building's perimeter, the exterior masonry thus turned into a rudimentary "curtain wall" system, heralding the use of curtain wall construction in future skyscrapers. This building's innovative structural system led to what is known as the "Chicago Skeleton," and eventually produced remarkable skyscrapers all over the world.

Reinforced concrete structures with damped seismic buckling-restrained bracing optimization using multi-objective evolutionary niching ChOA

  • Shouhua Liu;Jianfeng Li;Hamidreza Aghajanirefah;Mohammad Khishe;Abbas Khishe;Arsalan Mahmoodzadeh;Banar Fareed Ibrahim
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.147-165
    • /
    • 2023
  • The paper contrasts conventional seismic design with a design that incorporates buckling-restrained bracing in three-dimensional reinforced concrete buildings (BRBs). The suboptimal structures may be found using the multi-objective chimp optimization algorithm (MEN-ChOA). Given the constraints and dimensions, ChOA suffers from a slow convergence rate and tends to become stuck in local minima. Therefore, the ChOA is improved by niching and evolutionary operators to overcome the aforementioned problems. In addition, a new technique is presented to compute seismic and dead loads that include all of a structure's parts in an algorithm for three-dimensional frame design rather than only using structural elements. The performance of the constructed multi-objective model is evaluated using 12 standard multi-objective benchmarks proposed in IEEE congress on evolutionary computation. Second, MEN-ChOA is employed in constructing several reinforced concrete structures by the Mexico City building code. The variety of Pareto optimum fronts of these criteria enables a thorough performance examination of the MEN-ChOA. The results also reveal that BRB frames with comparable structural performance to conventional moment-resistant reinforced concrete framed buildings are more cost-effective when reinforced concrete building height rises. Structural performance and building cost may improve by using a nature-inspired strategy based on MEN-ChOA in structural design work.

토글 가새-고집적 마찰댐퍼를 설치한 철근콘크리트 모멘트 골조의 성능 평가 (Seismic Behavior of Reinforced Concrete Moment Frames Retrofitted by Toggle Bracing System with High Density Friction Damper)

  • 한상환;김지영;문기훈;이창석;김형준;이강석
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.133-140
    • /
    • 2014
  • The friction damper can be used for improving the seismic resistance of existing buildings. The damper is often installed in bracing members. The energy dissipation capacity of the damping systems depends on the type of the structure, the configuration of the bracing members, and the property of dampers. In Korea, there are numerous low- to mid-rise reinforced concrete moment frames that were constructed considering only gravity loads. Those frames may be vulnerable for future earthquakes. To resolve the problem, this study developed a toggle bracing system with a high density friction damper. To investigate the improvement of reinforced concrete frames after retrofit using the developed damped system, experimental tests were conducted on frame specimens with and without the damped system. The results showed that the maximum strength, initial stiffness and energy dissipation capacity of the framed with the damped system were much larger than those of the frame without the damped system.

Analysis of end-plate connections at elevated temperatures

  • Lin, Shuyuan;Huang, Zhaohui;Fan, Mizi
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.81-101
    • /
    • 2013
  • In this paper a robust 2-noded connection element has been developed for modelling the bolted end-plate connection between steel beam and column at elevated temperatures. The numerical procedure described is based on the model proposed by Huang (2011), incorporating additional developments to more precisely determinate the tension, compression and bending moment capacities of end-plate connection in fire. The proper failure criteria are proposed to calculate the tension capacity for each individual bolt row. In this new model the connection failure due to bending, axial tension, compression and shear are considered. The influence of the axial force of the connected beam on the connection is also taken into account. This new model has the advantages of both the simple and component-based models. In order to validate the model a total of 22 tests are used. It is evident that this new connection model has ability to accurately predict the behaviour of the end-plate connection at elevated temperatures, and can be used to represent the end-plate connections in supporting performance-based fire resistance design of steel-framed composite buildings.

조선전기 당(堂)·실(室) 결합 건축의 가구특성 분석 -방형 평면의 맞배직교형 지붕 가구를 중심으로- (A Study on the Structure of Combined Architecture of Dang and Sil in the Early Joseon Dynasty -Focusing on the Rectangular Plan and the Gable Roof Meeting at Right Angle-)

  • 김버들;이종서
    • 건축역사연구
    • /
    • 제26권2호
    • /
    • pp.31-42
    • /
    • 2017
  • This study investigates how the spatial recognition structure is emerging through the case of rectangular plan combined with a combination of Dang-Sil(堂室) and Gong(工) shape roof, and identifies a type of architecture in the early Joseon Dynasty that has never been revealed. The conclusion of this study is as follows. First, the Dang and the Sil are connected to each other, but the architectural elements such as pillars, frame, and windows are distinguished and appear as separate buildings. Second, the distinction between Dang and Sil is evident by the difference in the number of ridges and the shape of the roof. In addition, the roof and roof framework of the independent rooms and the rooms were common in the right angled architecture where the direction and the expandability of each structure were maintained. Third, the construction of the Dang-Sil combined structure, in which two or more structure frameworks were combined with the rectangular combined flat roof structure, gradually changed into a single structure with a single ridge. Fourth, this change means that people of the early Joseon Dynasty recognized the Dang and Sil as separate architecture, but the strict sense of spatial separation has disappeared over time.

Prediction of hysteretic energy demands in steel frames using vector-valued IMs

  • Bojorquez, Eden;Astorga, Laura;Reyes-Salazar, Alfredo;Teran-Gilmore, Amador;Velazquez, Juan;Bojorquez, Juan;Rivera, Luz
    • Steel and Composite Structures
    • /
    • 제19권3호
    • /
    • pp.697-711
    • /
    • 2015
  • It is well known the importance of considering hysteretic energy demands for the seismic assessment and design of structures. In such a way that it is necessary to establish new parameters of the earthquake ground motion potential able to predict energy demands in structures. In this paper, several alternative vector-valued ground motion intensity measures (IMs) are used to estimate hysteretic energy demands in steel framed buildings under long duration narrow-band ground motions. The vectors are based on the spectral acceleration at first mode of the structure Sa($T_1$) as first component. As the second component, IMs related to peak, integral and spectral shape parameters are selected. The aim of the study is to provide new parameters or vector-valued ground motion intensities with the capacity of predicting energy demands in structures. It is concluded that spectral-shape-based vector-valued IMs have the best relation with hysteretic energy demands in steel frames subjected to narrow-band earthquake ground motions.