• 제목/요약/키워드: frame work

검색결과 804건 처리시간 0.028초

Performance Evaluation of Ethernet Frame Burst Mode in EPON Downstream Link

  • Jia, Wen-Kang;Chen, Yaw-Chung
    • ETRI Journal
    • /
    • 제30권2호
    • /
    • pp.290-300
    • /
    • 2008
  • We apply IEEE 802.3 frame burst mode (FBM) to the Ethernet passive optical network (EPON) downstream link and compare its performance with non-frame burst mode for various traffic patterns. Although in light traffic loads (p<0.5) the efficiency of the FBM mechanism is not significant, it does feature high throughput, small jitter, low queue occupancy, and short queuing delay in optical line terminals under various traffic loads with various numbers of optical network units (ONUs). The FBM performance always approaches that of full-duplex mode, especially under heavy traffic loads (p>0.5). Moreover, an increase in number of ONUs will decrease the burst performance. Our work shows that FBM scheme is very useful for EPON transmission and has low design complexity.

  • PDF

The Precision of Lead Frame Etching Characteristics Using Monte-Carlo Simulations

  • Jeong, Heung-Cheol;Choi, Gyung-Min;Kim, Duck-Jool
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권1호
    • /
    • pp.73-78
    • /
    • 2007
  • The objective of this work was to simulate lead frame etching characteristics to optimize the etching process, Characteristics such as the etching factor and uniformity were investigated for different actual operating conditions, including pressure, distance from the nozzle tip, pipe pitch, and feed speed. The correlation between the etching and spray characteristics was analyzed to develop the etching model. Spray characteristics obtained from an experiment using a phase Doppler anemometer system were then simulated using a Monte-Carlo technique, The etching process model was coded in the Java language, The spray and etching characteristics were correlated with each other and simulated results agreed well with the measured data for a lead frame etching process, The optimal operating parameters under various conditions were successfully determined.

통발프레임 자동용접장비개발과 용접점에서 수작업과 자동작업의 전단강도 비교에 관한 연구 (Development of Automatic Welding Machine for Fish Trap Frame and Comparison of Shear Strength between Manual and Automatic Work at Welding Point)

  • 한창민;이상찬
    • 한국기계가공학회지
    • /
    • 제16권2호
    • /
    • pp.129-134
    • /
    • 2017
  • The process of producing a fish trap frame is very complicated and manual, so it is expensive, the quality of the product is unstable, the quality is not guaranteed, the durability is weak, and it cannot be used for a long time. Therefore, we made a fish trap frame-making machine to reduce the manpower and costs and to make robust products. This machine cuts the wire of mild steel to a certain size and then makes the connecting parts into a trapezoid shape by spot welding. In this study, the weld point shear strength between manual and automatic operation was compared and analyzed.

실 구조물 진동제어를 위한 점탄성 댐퍼 설계 및 적용 실험 (Designs and Tests for the Vibration Control of Full-Scale Steel Frame Structure with Added Viscoelastic Dampers)

  • 정정교;김두훈;김영찬;박진일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.687-692
    • /
    • 2002
  • In order to verify the effectiveness of adding visooelastic dampers to full-scale steel frame structure on the reduction of their seismic and wind response a experimental work was carried out. First, The test was conducted on the VE dampers subjected to sinusoidal excitations under a variety of ambient temperatures, frequency, and the damper strain. Results from these tests showed that the viscoelastic dampers have high energy dissipation capacity. Second, The vibration tests was conducted of the full-scale steel frame structure with md without added VE dampers at different temperatures. Viscoelastically damped full-scale structure test result on the effect of ambient temperature show that viscoelastic dampers are very effective in reducing excessive vibration of the structure due to sinusoidal excitation over a wide ringe of ambient temperature.

  • PDF

피에조콘 시험의 유한요소 해석 I (Finite Element Analysis Piezocone Test I)

  • 김대규
    • 한국지반공학회논문집
    • /
    • 제16권4호
    • /
    • pp.183-190
    • /
    • 2000
  • 본 연구에서는 피에조콘 시험의 유한요소해석을 점탄소성 bounding surface 구성모델과 large displacement large deformation 개념을 이용하여 수행하였다. 이에 따라 구성모델, 가상일의 방정식 및 관련 유한요소 식 등을 Updated Lagrangian reference frame에서 formulation 하였으며 지반의 거동은 theory of mixtures를 통하여 설명하였다. Theory of mixtures 역시 Updated Lagrangian reference frame에서 formulation하였다. 구성모델 중 점성 부분이 전체 formulation 과정에 중요한 영향을 미친다는 사실이 고찰되었다. 유한요소 해석의 결과는 실내에서 실시한 대형 모델시험의 결과와 비교, 분석하였다. Formulation 과정은 'I' 결과는 'II'에서 설명된다.

  • PDF

영상통신에서의 패킷 오류 은닉에 활용되는 워터마킹 기법 (Application of watermarking to error concealment in video communications)

  • 오태석;김용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.84-86
    • /
    • 2006
  • An informed watermarking algorithm is proposed in this work that aids in concealing packet loss errors in video communications. This watermark-based error concealment(WEC) method embeds a low resolution version of the video frame inside itself as watermark data. At the receiver, the extracted watermark is used as a reference for error concealment. The proposed DCT-based algorithm has features of informed watermarking in order to minimize the distortion of the host frame. At the encoder, a predictive feedback loop Is employed which helps to adjusts the strength of the scale factor Furthermore, some of the modified coefficients of the DCT signal are virtually free from distortion by employing bit- sign adaptivity. The performance of the detector is Qualitatively analyzed for error concealment applications where full-frame DCT embedding proved to be more advantageous.

  • PDF

Behavior of FRP strengthened RC brick in-filled frames subjected to cyclic loading

  • Singh, Balvir;Chidambaram, R. Siva;Sharma, Shruti;Kwatra, Naveen
    • Structural Engineering and Mechanics
    • /
    • 제64권5호
    • /
    • pp.557-566
    • /
    • 2017
  • Fiber reinforced polymer (FRP) sheets are the most efficient structural materials in terms of strength to weight ratio and its application in strengthening and retrofitting of a structure or structural elements are inevitable. The performance enhancement of structural elements without increasing the cross sectional area and flexible nature are the major advantages of FRP in retrofitting/strengthening work. This research article presents a detailed study on the inelastic response of conventional and retrofitted Reinforced Concrete (RC) frames using Carbon Fibre Reinforced Polymers (CFRP) and Glass Fiber Reinforced Polymers (GFRP) subjected to quasi-static loading. The hysteretic behaviour, stiffness degradation, energy dissipation and damage index are the parameters employed to analyse the efficacy of FRP strengthening of brick in-filled RC frames. Repair and retrofitting of brick infilled RC frame shows an improved load carrying and damage tolerance capacity than control frame.

비선형 회전 스프링 요소를 갖는 공간 프레임의 구조의 비선형 해석에 관한 연구 (A study on the nonlinear analysis of spatial frame structures with nonlinear rotational spring elements)

  • 이병채;박문식
    • 오토저널
    • /
    • 제12권2호
    • /
    • pp.29-42
    • /
    • 1990
  • Three dimensional frame structures with such nonlinearities as large displacements, medium rotations, plastic hinges and local defects are efficiently analyzed by introducing the nonlinear rotational spring. Formulations are based on the incremental updated Lagrangian descriptions and the virtual work principle, Axial displacement and twisted angle in beam elements are interpolated linearly, while bending displacements are approximated by the Hermite polynomials. The modified are length method is used as a solution method. The moment-angle of rotation relationship obtained analytically or experimentally can be easily incorporated into the solution procedure. Several examples tested show that the present method can be used efficiently in analyzing nonlinear frame structures with plastic hinges or local defect.

  • PDF

Energy absorption of fibrous self compacting reinforced concrete system

  • Senthil, K.;Satyanarayanan, K.S.;Rupali, S.
    • Advances in concrete construction
    • /
    • 제4권1호
    • /
    • pp.37-47
    • /
    • 2016
  • The objective of the present work is to evaluate the influence of two different methods of improving the ductility of Reinforced Concrete Frames and their influence on the full range behavior of the frames with M40 grade of concrete. For this purpose one fourth scale reinforced concrete square frames are experimentally tested subjected to static cyclic loading for three cases and monotonic loading for one case. The parameters are varied as method introducing ductility to the frame viz. (i) by using conventional concrete (ii) adding 1% of steel fibres by volume of concrete at hinging zones (iii) using self-compacting concrete with fibres at hinging zones. The energy absorption by ductile and non-ductile frames has been compared. The behavior of frames tested under cyclic loading have revealed that there is a positive trend in improvement of ductility of frames when fibrous concrete is used along with self-compacting concrete.

Evaluation of dynamic increase factor in progressive collapse analysis of steel frame structures considering catenary action

  • Ferraioli, Massimiliano
    • Steel and Composite Structures
    • /
    • 제30권3호
    • /
    • pp.253-269
    • /
    • 2019
  • This paper investigates the effects of the tensile catenary action on dynamic increase factor (DIF) in the nonlinear static analysis for progressive collapse of steel-frame buildings. Numerical analyses were performed to verify the accuracy of the empirical and analytical expressions proposed in the literature in cases where the catenary action is activated. For this purpose, nonlinear static and dynamic analyses of a series of steel moment frame buildings with a different number of spans and stories were carried out following the alternate path method. Different column removal scenarios were considered as separate load cases. The dynamic increase factor that approximately compensates for the dynamic effects in the nonlinear static analysis was selected so to match results from the nonlinear dynamic analysis. The study results showed that the many expressions in literature may not work in cases where the catenary stage is fully developed.