• 제목/요약/키워드: frame buildings

검색결과 688건 처리시간 0.025초

고강도강 혼용 사용을 위한 SM570TMC강 보-기둥 접합부의 성능평가 및 해석 비교 (Performance Examination and Comparison of Steel Beam-Column Connection in SM570TMC for Mixed-Use)

  • 김문정;조석희;하태욱;강창훈;최우혁;김정학
    • 복합신소재구조학회 논문집
    • /
    • 제4권3호
    • /
    • pp.22-29
    • /
    • 2013
  • In recent years, the construction of high-rise buildings are promoted. According to these, there are many needs about new technologies to strengthen the building performance and high-strength steel is regarded as one of these for promoting building performance. In Korea, high-strength steels which stress are over 600MPa are on market and in aborad, super high-strength steels over 1000MPa are developing and they expected to promote the building performance. But there are still doubts about applying high-strength steel members because of size effect and worry of brittle fracture. In this reports, we propose results of performance and analysis tests for use with general steel. We propose the characteristic of high-strength steels first and next the results of performance test to show they satisfy the performance that designers expect. And last, we compare the results of test and analysis for acquire the alanysis reliability in non-linear analysis with high-strength steels.

기초 및 바닥층 동시타설 공사의 개선방안 연구 (An Improvement of Concurrent Placement of Footing and Slab Concrete)

  • 이동훈;최재휘;길종일;서덕석;김선국
    • 한국건축시공학회지
    • /
    • 제9권6호
    • /
    • pp.121-129
    • /
    • 2009
  • 중소규모 건축물의 시공 현장은 기초의 크기가 작고 터파기 깊이가 얕은 경우가 많다. 이런 경우 일반 거푸집을 이용하여 2회에 걸쳐 타설하는 기존의 재래식 공법보다 매립형 보조거푸집을 이용하여 기초 및 지중보와 바닥슬래브를 동시에 타설하는 공법을 사용하면 지하층 골조공기의 단축과 그에 따른 원가절감을 기대 할 수 있다. 기존의 매립형 보조거푸집은 거푸집의 종류에 따라서 자재와 인건비에 따른 원가, 품질상의 문제들이 있기 때문에 사용에 제약이 있다. 따라서 본 연구에서는 개선방안으로써 발포폴리스티렌을 매립형 보조거푸집으로 이용한 기초 및 지중보와 바닥슬래브 콘크리트 동시 타설공법을 제안하고, 기존의 공법들과 비교하며, 공법별 평가를 통하여 효용성을 검증하고자 한다.

채널 형강을 이용한 비좌굴 Knee Bracing System의 내진성능에 대한 실험적 연구 (Experimental Study on Buckling Restrained Knee Bracing Systems using Channel Scetions)

  • 이진;이기학;이한선;김희철;이영학
    • 한국강구조학회 논문집
    • /
    • 제21권1호
    • /
    • pp.71-81
    • /
    • 2009
  • 본 연구에서는 지진에 대해 보강 효과가 뛰어난 비좌굴 가새를 바탕으로 필로티를 가진 중저층 집합주택에 적합한 비좌굴 knee brace에 대해 총 5개의 실험체를 제작하여 실험을 실시하였다. 이는 공간활용이 우수하고 동선이나 시야를 방해하지 않으며, 시공 방법 또한 간단하여 필로티 층을 가진 중저층 건물에 대해 유리하다는 장점을 가지고 있다. 각 실험체의 변수로는 중심코어의 크기, 외부 보강재의 크기, 단부의 크기 및 형태로 정하였으며 실험결과 중심코어의 크기가 가장 큰 영향을 미치는 것으로 나타났다. 외부 보강재의 크기는 중심코어의 크기에 비해 효과는 미비하나, 파괴거동이나 연성도 측면에서는 영향을 미치는 것으로 나타났다. 실험을 통해 얻어진 힘-변위 그래프는 인장과 압축에서 비교적 안정적인 이력거동을 보였으며 AISC 2005 Seismic Provision 규정에서 제시한 연성도와 에너지 소산능력 측면에서도 충분한 효과를 발휘하였다. 또한 설계 층간 변위비의 2배까지 가력을 실시하였을 때, 가새의 전체 좌굴이나 국부적인 좌굴이 일어나지 않아야 한다는 조항을 만족하는 것으로 나타났다.

뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체 제안을 위한 연구 (Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures)

  • 옥치열;김재준
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.7-15
    • /
    • 2016
  • 단면형상계수는 세계적으로 흔하게 활용되는 공학적 내화구조 성능평가 방법이지만 국내의 경우 단면형상계수의 적용을 위한 제도가 아직 마련되어 있지 못하다. 실제 우리나라의 대부분의 철골조 건축물에서 원형 강관의 사용을 흔히 볼 수 있으나, 인정기관으로부터 성능을 인정받은 뿜칠 피복 철골 보 및 기둥은 대부분이 H형강으로 한정되어 있다. 비재하 시험의 특성상 H형강은 관련규정에 따른 시험규격으로 부재에 대한 평가를 수행하여 크기의 제한 없이 인정범위가 부여되나, 이형 강관의 경우는 형상별로 별도의 내화성능에 대한 인정을 받아야 한다. 본 연구에서는 합리적인 내화구조의 인정범위를 설정할 수 있도록 단면형상계수를 활용하여 뿜칠 피복재의 원형 강관의 적용을 위한 표준 시험체 규격을 제시하고자 한다.

한지창호의 실내 온.습도 조절효과에 관한 실험적 연구 (An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control)

  • 장길수;박사근;송민정;신훈
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • 제19권5호
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

접합부 상세에 따른 복합 병렬 전단벽 시스템의 구조 성능 (Structural Performance of Hybrid Coupled Shear Wall System Considering Connection Details)

  • 박완신;윤현도;김선웅;장영일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권3호
    • /
    • pp.128-137
    • /
    • 2012
  • 복합 병렬 전단벽(Coupled shear walls)은 커플링 보와 철근콘크리트 벽체로 구성되어 바람이나 지진 등의 횡하중으로부터 유발된 전도모멘트의 상당 부분을 철골 연결보의 커플링 작용에 의하여 골조 작용(Frame action)을 의하여 횡력에 효율적으로 저항하게 된다. 본 연구에서는 접합부 상세에 따른 복합병렬 전단벽의 접합부 강도에 대한 규준식을 정립하기 위한 선행연구로서 병렬 전단벽 접합부에서 커플링 보의 매립길이 및 벽체 두께를 주변수로 실험적 연구를 수행하여 접합부 상세에 따른 복합 병렬 전단벽 시스템의 거동특성을 규명하고자 하였다. 본 실험결과, 실험체의 거동 및 내력은 매립길이 및 접합부 상세에 많은 영향을 받는 것으로 나타났으며 향후 설계시 이에 대한 영향을 반영해야 할 것으로 판단된다.

철근부식에 의한 철근콘크리트골조의 구조성능분석 (Structural Performance Investigation for the Reinforced Concrete Frames Deteriorated by the Reinforcement Corrosion)

  • 최세운
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.563-570
    • /
    • 2015
  • 기존 구조물의 손상평가에 관한 연구는 지진 등과 같은 과도한 하중에 의한 손상을 고려하였다. 그러나 구조물은 과도한 하중없이도 장기간의 시간에 따라 염화물, 탄성화 등과 같은 이유로 노후화가 진행되어 구조성능이 저하될 수 있다. 그래서 구조물의 건전도를 효과적으로 관리하기 위해서는 노후화에 의한 구조성능 저하도 검토되어야 한다. 본 연구에서는 염화물에 의한 철근의 부식을 노후화 요인으로 고려한다. 철근부식에 의한 재료의 구조성능 저하를 고려하기 위해 부식정도에 따른 철근의 단면적, 항복강도, 파단변형률, 피복 콘크리트 강도 등을 예측한다. 이를 구조모델링에 적용하여 구조부재 및 구조물의 구조성능 저하를 분석한다. 구조부재의 구조성능을 분석하기 위해 모멘트-곡률 해석을 수행한다. 구조물 레벨의 구조성능을 고려하기 위해, 고유치해석을 통한 고유주기와 모드형상을 분석한다. 또한 비선형 정적해석을 통해 구조물의 강도와 변형성능을 분석한다.

지진지반운동의 수직성분을 고려한 증진지역 건축구조물의 지진응답평가 (Evaluation of Seismic Responses for Building in Moderate Seismicity Regions Considered Vertical Earthquake Ground Motions)

  • 한덕전;고현
    • 한국공간구조학회논문집
    • /
    • 제9권1호
    • /
    • pp.69-78
    • /
    • 2009
  • 최근의 근단층지반운동인 Northridge 지진(1994, 미국), Kobe 지진(1995, 일본), Izmit 지진(1990, 터키)은 큰 수직성분의 영향으로 건축물 및 교량에 심각한 손상을 주었다. 일반적인 건축구조물의 내진설계에서 지진하중의 수직성분을 고려하여 설계하는 경우는 드물다. 본 연구에서는 지진하중의 수직성분 영향의 고려 유무에 따른 예제구조물의 기둥부재의 축력의 변화와 부재 단부의 소성힌지회전각을 산정하여 시스템의 손상상태를 평가하여 보았다. 해석결과 축력의 증가는 기둥부재의 손상에 의한 전체 구조시스템의 story collapse mechanism의 가능성을 주게 되므로 근단층지반운동이 예상되는 부분에서는 지진하중의 수직성분에 대한 영향을 고려하여야할 것으로 판단된다.

  • PDF

보급형 신한옥을 위한 부위별 공법 개발 및 영향도 분석 (New Building Materials and Methods for Modernized Korean Housing (Hanok))

  • 김민;김효선;류재선;정영수
    • 한국건설관리학회논문집
    • /
    • 제15권2호
    • /
    • pp.23-32
    • /
    • 2014
  • 한옥에 대한 관심이 급증을 하고 있는 가운데, 가격경쟁력을 갖춘 신한옥이 개발되고 있다. 이러한 신한옥 개발에 있어서, 공법의 개발은 필수적이다. 이에, 본고에서는 신한옥의 개발과정 중 실제 건설된 전통한옥 1채와 신한옥 2채의 사례를 중심으로 신공법 사례 소개와 각 한옥의 부위별 공법을 비교하였다. 또한, 부위별 공법별로 공사비 및 공기의 영향도를 분석하였다. 그 결과, 전통한옥 대비 신한옥의 공사비는 모든 부위에서 저감되었으며, 공기는 대부분의 부위에서 단축되었다. 두 신한옥 사례의 분석 결과, 목재 구조체와 지붕의 공사비 및 공기 비율이 가장 높았으며, 다음으로 벽체, 바닥, 창호, 기초 순으로 나타났다. 효과적인 공사비 저감 및 공기 단축을 위해서는 목재 구조체 및 지붕 부위의 공법개발에 집중해야 한다.