• Title/Summary/Keyword: fracture set

Search Result 188, Processing Time 0.025 seconds

Evaluation of fracture density distribution for the design of grouting works in fractured rocks (그라우팅 설계를 위한 절리밀도분포 산출법 개발)

  • 김중열;김유성
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.627-634
    • /
    • 2002
  • To facilitate a drilling plan for grouting in fractured rock, an algorithm of practical use associated with a new term “fracture density distribution”or“fracture tomogram”is developed. It is well known that Televiewer data(amplitude and traveltime image) provide detailed information about not only dip and dip direction of each fracture but also its aperture size estimated by an appropriate evaluation algorithm. A selected plane section of medium around a borehole or the cross section between two boreholes is discretized into a two dimensional grid of cells(rectangular elements). As each elongated(straight) fracture passes through the cells, the corresponding aperture size value is successively summed up in each cell, depending on the fracture length segment. In this, the fracture lines can be determined by intersecting of each fracture plane with the selected plane section. If the fracture line does not pass through a particular grid element, the segment length is set to zero. The final value(aperture size value of each cell) derived from all the detected fractures constitutes the fracture density distribution of the selected plane section, Field examples are illustrated, which will prove the benefit of the suggested algorithm for several kinds of grouting works.

  • PDF

Geometric and Kinematic Characteristics of Fracture System in the Sancheong Anorthosite Complex, Korea (산청 회장암복합체 내 발달하는 단열계의 기하학적·운동학적 특성)

  • Lee, Deok-Seon;Kang, Ji-Hoon
    • The Journal of the Petrological Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.389-400
    • /
    • 2016
  • The study area, which is located in the southeastern part of the Jirisan province of the Yeongnam massif, Korea, consists mainly of the Precambrian Sancheong anorthosite complex and the Jirisan metamorphic rock complex, the Mesozoic granitoids which intruded them. Several fracture sets with various geometric indicators, which determine their relative timing and shear sense, are well observed in the Sancheong anorthosite complex. The aim of this study is to determine the development sequence of extension fractures, the movement sense and development sequence of shear fractures in the Sancheong anorthosite complex on the basis of detailed analysis of their geometric indicators. This study suggests fracture system of the Sancheong anorthosite complex was formed at least through five different fracturing events, named as Dn to Post-Dn+3 phases. (1) Dn phase: extension fracturing event of NNW trend. The fracture set experienced the reactivations of dextral ${\rightarrow}$ sinistral shearing with the change of stress field afterward. (2) Dn+1 phase: extension fracturing event of (N)NE trend. The fracture set experienced the reactivations of sinistral ${\rightarrow}$ sinistral ${\rightarrow}$ dextral. (3) Dn+2 phase: extension fracturing event of NW trend. The fracture set experienced the activated of dextral shearing. (4) Dn+3 phase: extension fracturing event of N-S trend. (5) Post-Dn+3 phase: extension fracturing event of (E)NE trend. Dn deformation formed during the early Songnim orogeny. Dn+1 deformation formed during the late Songnim orogeny. Dn+2 deformation formed during the Daebo orogeny. Dn+3 deformation formed during the Bulguksa orogeny.

The Relation of Fracture Properties to Hydraulic Conductivity in Volcanic Rocks of the Northern Yosu Area (여수 북부지역 화산암의 단열특성과 수리전도도와의 관계)

  • 조성일;송무영;김경수;이은용
    • The Journal of Engineering Geology
    • /
    • v.9 no.3
    • /
    • pp.227-241
    • /
    • 1999
  • Groundwater flow in a fractured rock mass is related to the geometric characteristics of the fracture system. The objective of this study aims to analyze the probabilistic density function of fracture properties md their relations to the hydraulic conductivity in volcanic rocks of the northern Yosu area. Fracture characteristics were investigated by core logging and acoustic televiewer logging in four boreholes and the hydraulic conductivity was obtained from the constant pressure injection and fall-off tests. The 303 fractures were grouped into three sets by their orientation and three fracture types by the degree of opening in aperture. As a result of the study, the hydraulic conductivity in the test section intersected by open and semi-open fractures, conductive fractures, and set 1 fractures was very high, while closed fractures did rarely affect the hydraulic conductivity. It was recognized that the hydraulic conductivity in a fractured rock mass was preferentially affected by the aperture size of conductive fractures and fracture intersection frequency and size, secondly.

  • PDF

A Case Study on Stochastic Fracture Network Modeling for Rock Slopes of Busan-Ulsan Highway(Reach 5) (부산-울산 고속국도(5공구)에 위치한 암반사면의 추계론적 절리연결구조 모사에 대한 사례연구)

  • Heo, In-Sill;Um, Jeong-Gi;Kim, Yang-Phil;Kim, Kook-Han;Lee, Young-Kyun
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.337-349
    • /
    • 2006
  • Seven hundred and fifty one fractures of the rhyolitic tuffaceous rock masses were mapped using 6 scanlines placed on rock slope exposures that were within 8.02 km of Busan-Ulsan highway. These data were analyzed to find the number of fracture sets that exist in the rock slopes and the probability distributions of orientation, spacing, trace length and fracture size in 3-D for each of the fracture sets. All the fracture set orientation distributions exhibit high variability. The Fisher distributions were found to be unsuitable to represent the statistical distribution of orientation for most of the fracture sets. The probability distributions, gamma, exponential and lognormal were found to be highly suitable to represent the distribution of spacing and semi-trace length of fracture sets. In obtain-ing these distributions, corrections were applied for sampling biases associated with spacing and trace length. The generated fracture system in 3-D was used to make predictions of fracture traces for each fracture set on 2-D win-dows. Developed stochastic 3-D fracture network for the rock mass was validated by comparing statistical proper-ties of the observed fracture traces on scanlines with the predicted fracture traces on the scanlines. This exercise fumed out to be successful.

A Study on the Die Set Design for Multi-Hole Extrusion Process Using Taguchi Method (다구찌 방법을 이용한 다발압출 금형설계에 관한 연구)

  • 조성진;이재원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.322-325
    • /
    • 2000
  • In the previous report1), the grinding characteristics of quartz were investigated. In this paper, the grinding mechanisms of brittle materials including ceramics and quartz are modeled and a new parameter SDR(Surface roughness Direction Ratio) is proposed to characterize the grinding mechanisms of such materials. A set of experiments were performed to verify the effectiveness of the suggested parameter. The experimental results indicate that the plastic deformation is the dominant material removal mode at the grinding conditions which show the higher value of SDR. In the case of quartz, the material was removed by brittle fracture in a lower value of SDR and by plastic deformation in a higher value of it. SDR is not affected by wheel mesh size when brittle fracture occured. But in the plastic deformation case, SDR value increases with wheel mesh size.

  • PDF

Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study

  • Taramsari, Mehran;Kajan, Zahra Dalili;Bashirzadeh, Parinaz;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.171-177
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. Materials and Methods: In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. Results: The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. Conclusion: There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.

Aggregate shape influence on the fracture behaviour of concrete

  • Azevedo, N.Monteiro;Lemos, J.V.
    • Structural Engineering and Mechanics
    • /
    • v.24 no.4
    • /
    • pp.411-427
    • /
    • 2006
  • The Discrete Element Method, DEM, is increasingly used in fracture studies of non-homogeneous continuous media, such as rock and concrete. A 2D circular rigid DEM formulation, developed to model concrete, has been adopted. A procedure developed to generate aggregate particles with a given aspect ratio and shape is presented. The aggregate particles are modelled with macroparticles formed by a group of circular particles that behave as a rigid body. Uniaxial tensile and compression tests performed with circular and non-circular aggregates, with a given aspect ratio, have shown similar values of fracture toughness when adopting uniform strength and elastic properties for all the contacts. Non-circular aggregate assemblies are shown to have higher fracture toughness when different strength and elastic properties are set for the matrix and for the aggregate/matrix contacts.

Panfacial bone fracture: cephalic to caudal

  • Yun, Seonsik;Na, Youngcheon
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.1
    • /
    • pp.1-2
    • /
    • 2018
  • Theoretically, panfacial bone fractures involve all three areas of the face: frontal bone, midface, and mandible. In practice, when two out of these three areas are involved, the term "panfacial bone fracture" has been applied. We can use physical examination, simple radiologic examination, and computed tomography study for diagnosis. Linear fracture are treated by conservative treatment. But, most of panfacial bone fracture patients need to be treated by open reduction and internal fixation. Facial width is most important thing that we need to care during operation. There are many ways about sequence like "top to bottom," "bottom to top," "outside to inside," or "inside to outside" and the authors prefer "top to bottom" and "outside to inside" ways. The authors apply arch bar from the first of surgery and then, set frontal bone fracture, midface fracture and mandible fracture in sequence. Usually, we remove the stitches for 5 days after surgery and the intraoral stitch removed after 2 weeks. Usually arch bar is going to be removed 4 weeks after surgery. We could get acceptable results with the above way.

A Study on the Fracture Detection of Multi-Point-Tool (다인공구의 파손검출에 관한 연구)

  • Choi, Young Kyu;Ryu, Bong Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.67-77
    • /
    • 1995
  • In modern industry the requirement of automation of manufacturing process increases so that unmanned system has been popular as an ultimate goal of modern manufacturing process. In unmanned manufacturing process the tool fracture is a very serious problem because it results in the damage of workpieces and can stop the operation of whole manufa- turing system. In this study, image processing technique is used to detect the fracture of insert tip of face milling using multi-point-tool. In order to acquire the image information of fracture shape of rotation insert tip. We set up the optical system using a light beam chopper. In this system we can reduce the image degradation generated from stopped image of rotating insert tip using image restoration technique. We calculated the mean square error to diagnose the condition of tool fracture, and determind the criteria of tool fracture using experimental and staticstical method. From the results of this study we've developed non- contact detection technique of tool fracture using image processing method and proposed the fracture direction of automation and unmanned system considering the optimal time of tool change milling.

  • PDF

MRI Evaluation of Suspected Pathologic Fracture at the Extremities from Metastasis: Diagnostic Value of Added Diffusion-Weighted Imaging

  • Sun-Young Park;Min Hee Lee;Ji Young Jeon;Hye Won Chung;Sang Hoon Lee;Myung Jin Shin
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.812-822
    • /
    • 2019
  • Objective: To assess the diagnostic value of combining diffusion-weighted imaging (DWI) with conventional magnetic resonance imaging (MRI) for differentiating between pathologic and traumatic fractures at extremities from metastasis. Materials and Methods: Institutional Review Board approved this retrospective study and informed consent was waived. This study included 49 patients each with pathologic and traumatic fractures at extremities. The patients underwent conventional MRI combined with DWI. For qualitative analysis, two radiologists (R1 and R2) independently reviewed three imaging sets with a crossover design using a 5-point scale and a 3-scale confidence level: DWI plus non-enhanced MRI (NEMR; DW set), NEMR plus contrast-enhanced fat-saturated T1-weighted imaging (CEFST1; CE set), and DWI plus NEMR plus CEFST1 (combined set). McNemar's test was used to compare the diagnostic performances among three sets and perform subgroup analyses (single vs. multiple bone abnormality, absence/presence of extra-osseous mass, and bone enhancement at fracture margin). Results: Compared to the CE set, the combined set showed improved diagnostic accuracy (R1, 84.7 vs. 95.9%; R2, 91.8 vs. 95.9%, p < 0.05) and specificity (R1, 71.4% vs. 93.9%, p < 0.005; R2, 85.7% vs. 98%, p = 0.07), with no difference in sensitivities (p > 0.05). In cases of absent extra-osseous soft tissue mass and present fracture site enhancement, the combined set showed improved accuracy (R1, 82.9-84.4% vs. 95.6-96.3%, p < 0.05; R2, 90.2-91.1% vs. 95.1-95.6%, p < 0.05) and specificity (R1, 68.3-72.9% vs. 92.7-95.8%, p < 0.005; R2, 83.0-85.4% vs. 97.6-98.0%, p = 0.07). Conclusion: Combining DWI with conventional MRI improved the diagnostic accuracy and specificity while retaining sensitivity for differentiating between pathologic and traumatic fractures from metastasis at extremities.