• 제목/요약/키워드: fracture fixation internal

검색결과 332건 처리시간 0.022초

전위된 견갑골 관절내 골절의 관혈적 정복 및 내고정술 (Open Reduction and Internal Fixation of Displaced Intra-Articular Fractures of the Glenoid)

  • 김승기;박종범;최우성;권영정;장한
    • Clinics in Shoulder and Elbow
    • /
    • 제1권2호
    • /
    • pp.230-235
    • /
    • 1998
  • Fractures of the scapula are relatively uncommon injuries and treatment in the vast majority of cases remains nonsurgical and the results have been quite satisfactory. But the scapular fracture itself may be neglected because of its high incidence of many kinds of associated injuries so its delayed treatment sometimes gives bad and unpredictable results. Although open reduction and internal fixation has been accepted as the treatment of choice for displaced intra-articular fractures in many anatomical regions, there has been no definite treatment principles of surgical indications and approaches in the glenohumeral joint. At our institution, II displaced intra-articular fractures of the glenohumeral joint were treated with open reduction and internal fixation from March 1993 to February 1997. This paper reports the results of treating 11 displaced intra­articular fractures of the glenoid by open reduction and internal fixation. There were 10 men and one woman and the fractures were classified according to Ideberg : Type Ⅰa(4), Type Ⅱ(3), Type Ⅲ(1), Type IV(1), Type Va(1), and Type Vc(1).

  • PDF

쇄골 골절의 관혈적 정복 및 내 고정술 후 발생한 쇄골하 동맥의 혈전증 - 증례 보고 - (The Subclavian Artery Thrombosis after Open Reduction and Internal Fixation of Clavicular Fracture - A Case Report -)

  • 문은선;김명선;정광철;임근영
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.211-215
    • /
    • 2006
  • Reported in this article is a case report of a patients who developed limb threatening ischemia as a consequence of a subclavian artery thrombosis resulting from screws. The subclavian artery thrombosis after open reduction and internal fixation of clavicle fracture, when it occurs, should be treated promptly by plate removal and claviculectomy. It can be prevented by placing screws in locations away from the underlying neurovascular structures.

Open reduction and internal fixation of mandibular fracture in an 11-month-old infant: a case report

  • Kim, Tae-Wan;Seo, Eun-Woo;Song, Seung-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권2호
    • /
    • pp.90-93
    • /
    • 2013
  • Mandibular fractures in infants are rare. This case report describes management of a mandibular fracture in an 11-month-old infant using a microplate and screws with open reduction. The surgical treatment was successful. Because the bone fragments were displaced and only the primary incisors had erupted, conservative treatment, such as an acrylic splint and circummandibular wiring, was not recommended. Nine weeks after surgery, the microplate was removed. The results showed complete clinical and radiological bone healing with normal eruption of deciduous teeth.

Periprosthetic Acetabular Fracture after Total Hip Arthroplasty: A Report on Two Cases

  • Joonkyoo Kang;Chan Young Lee;Taek-Rim Yoon;Kyung-Soon Park
    • Hip & pelvis
    • /
    • 제36권2호
    • /
    • pp.155-160
    • /
    • 2024
  • We report two cases of postoperative total hip arthroplasty periprostehtic fracture of the acetabulum which treated by open reduction with internal fixation without acetabular cup revision. From these cases, we should consider open reduction with internal fixation as the first treatment option in cases where spot welding of the cup to the host bone is observed.

Orthogonal versus Parallel Plating for Distal Humeral Fractures

  • Moon, Jun-Gyu;Lee, Ji-Ho
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.105-112
    • /
    • 2015
  • In orthopedic trauma surgery, treatment of intraarticular distal humerus fractures is a challenge. With development of implants and biomechanical studies, surgical strategies with recommendations including preoperative computed tomography images, proper approaches and open reduction and internal fixation with dual plates have emerged. In addition, as an effort to provide stable fixation to permit early elbow motion, different methods of internal fixation, particularly plate configuration, have evolved. Using dual plates, either oriented parallel to each other or orthogonal, stable fixation has been achieved and satisfactory clinical outcomes have been reported. With rationales and advantages/disadvantages of each plate configuration, both techniques are selected according to surgeons' preference, and, in specific cases, one could be preferred over another. The key to successful fixation by either technique is obtaining anatomical reduction with restoration of two stable columns of the distal humerus.

흡수성 고정판과 나사를 이용한 중수골 골절의 치료 (Treatment of Metacarpal Bone Fracture Using Biodegradable Plates and Screws)

  • 조정목;은석찬;백롱민
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.458-464
    • /
    • 2011
  • Purpose: Metacarpal fractures are common hand injury that may require operative intervention to ensure adequate reduction and stabilization. Traditionally, titanium miniplate was used for rigid fixation of bone fractures. However, the use of permanent plate lends itself to multiple complications such as infection, exposure of the hardware, tendon adhesions, tendon rupture, prolonged pain, bony atrophy and osteoporosis (stress shielding), metal sensitization, and palpation under the skin. This study evaluated the usefulness and stability of biodegradable plates and screws for treatment of metacarpal bone fractures. Methods: There was 17 patients who had surgery for metacarpal bone fracture from April 2007 to June 2010. All patients had open reduction and internal fixation. We used absorbable plates and screws (Inion CPS$^{(R)}$) for internal fixation. Postoperative results were assessed with x-ray. Stability of plates and screws, healing process and its complications were observed by clinical and radiographic assessment. Results: All patients were successfully reduced of bone fracture, and fixations with absorbable plates and screws were stable. The mean follow up period was 7.1 months. 2 patients complained postoperative pain, but they were relieved with analgesics. All patients experienced transient stiffness, but they were relieved with active assistive range of motion after removal of splint. No patients suffered complications which could be occurred by using metallic plate. Conclusion: There was no critical complications such as re-fracture or nonunion among patients. No patients suffered side effects related with metallic implants. Biodegradable implants can offer clinically stable and attractive alternative to metallic implants to stabilize metacarpal bone fractures in the hand.

Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture

  • Shin, Woo Jin;Chung, Young Woo;Kim, Seon Do;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • 제23권4호
    • /
    • pp.198-202
    • /
    • 2020
  • Simple clavicle fractures can achieve satisfactory results through conservative treatment, and the less frequency of nonunion. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

생흡수성판을 이용한 하악골 골절의 치료 : 일차보고 (TREATMENT OF MANDIBLE FRACTURES USING BIOABSORBABLE PLATES: PRELIMINARY STUDY)

  • 김영균;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권6호
    • /
    • pp.570-575
    • /
    • 2001
  • This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Thirty-four fractures of the mandible in 27 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pre-tapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 5.3 days. Patients were evaluated for complications during the follow-up period, which ranged from 2 to 18 months. Five patients(18.5%) experienced complications. These included infection (four patients), and premature occlusal contact(one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures with the advantage that they do not need to be removed.

  • PDF

Neer 분류 제 2형 원위부 쇄골 골절의 mini-T형 금속판 고정 (Mini-T Plate Fixation for Neer Type II Distal Clavicle Fracture)

  • 염재광;이상림;라호종
    • Clinics in Shoulder and Elbow
    • /
    • 제12권1호
    • /
    • pp.1-6
    • /
    • 2009
  • 목적: 불안정성 쇄골 원위부 골절에 대하여 mini-T 금속판을 이용한 수술적 치료를 시행 후 임상적 및 방사선학적 결과를 알아보고자 하였다. 대상 및 방법: 2004년 12월부터 2007년 7월까지 쇄골 원위부 골절 중 Neer 분류 제 2형인 불안정성 골절에 대하여 mini-T 금속판을 이용한 수술을 시행한 환자 중 1년 이상 추시 관찰이 가능하였던 15예를 대상으로 임상적 및 방사선학적 결과를 분석하였다. 결과: 방사선학적 골유합은 평균 3.1개월(3~4개월)에 이루어졌으며 심부 감염이나 고정 실패 등의 합병증은 없었다. 최종 추시 시 미국 견주관절학회 평가 점수(ASES score)는 평균 97점(85~100점)으로 양호한 결과를 보였으며, 견관절의 운동 범위도 1예를 제외하고 모든 예에서 정상으로 회복된 소견을 보였다. 결론: 불안정성 쇄골 원위부 골절에 대하여 mini-T 금속판을 이용한 수술 방법은 양호한 임상적 및 방사선학적 결과를 보여 좋은 수술 방법으로 사료되나 더 많은 증례를 통한 장기적인 결과 분석이 필요하리라 생각된다.

후방십자인대 견열 골절의 관절경적 정복술(증례 보고) (Arthroscopic Fixation for Avulsion Fracture of the Posterior Cruciate Ligament(Cases Report))

  • 김경택;손성근;양성욱
    • 대한관절경학회지
    • /
    • 제2권2호
    • /
    • pp.173-176
    • /
    • 1998
  • Isolated posterior cruciate ligament injuries are rare and their management is controversial. But, there is general concept that a bony avulsion of posterior cruciate ligament should be repaired. The treatments for the bony avulsion of posterior cruciate ligament were conservative treatment, open reduction and internal fixation and arthroscopic fixation. We report 2 cases of posterior cruciate ligament avulsion fractures, which were arthroscopically reduced and stabilized with cannulated screws and Kirschner wires, and introduce the arthroscopic fixation technique.

  • PDF