• 제목/요약/키워드: fracture fixation internal

검색결과 320건 처리시간 0.024초

견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술 (Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation)

  • 고상훈
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

후방까지 연장된 안와하벽골절에서 안구함몰 예방을 위한 Medpor® 내고정술 (Internal Fixation of Medpor® Implant for Prevention of Enophthalmos in Posteriorly Extended Orbital Floor Fracture)

  • 석정훈;지소영;김태범;양완석
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.55-61
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effectiveness of internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw which is used for prevention of enophthalmos in posteriorly extended large orbital floor fracture. Methods: From Jun. 1997 to Dec. 2007, 21 patients who were diagnosed with posteriorly extended large orbital floor fractures were classified into two groups. One group(n=11) had undergone reduction surgery with regular $Medpor^{(R)}$ sheets without any fixation method, while the other group(n=10) had their $Medpor^{(R)}$ sheets fixed with the $BioSorb^{TM}FX$ screws. The two groups were evaluated by comparison of their enophthalmos degree and effectiveness. Results: In the non-fixation group, six patients had enophthalmos preoperatively and three of them showed persistent enophthalmos postoperatively. In postoperative CT examination, displacement of $Medpor^{(R)}$ implant with soft tissue impaction into maxillary sinus was observed in the patients. In the screw fixation group, three patients had enophthalmos preoperatively, but none of them suffer from complication such as residual enophthalmos, soft tissue impaction, muscle entrapment or optic nerve compression postoperatively. Conclusion: Internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw on the medial surface of orbital floor provides firm stabilization of implants and surrounding soft tissues and can be an effective option especially when postoperative implant displacement or malposition was expected.

Is All Anterior Oblique Fracture Orientation Really a Contraindication to Anterior Screw Fixation of Type II and Rostral Shallow Type III Odontoid Fractures?

  • Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권6호
    • /
    • pp.345-350
    • /
    • 2011
  • Objective : It is debatable whether an anterior oblique fracture orientation is really a contraindication to anterior odontoid screw fixation. The purpose of this study was to investigate the feasibility of anterior odontoid screw fixation of type II and rostral shallow type III fracture with an anterior oblique fracture orientation. Methods : The authors evaluated 16 patients with type II and rostral shallow type III odontoid fracture with an anterior oblique fracture orientation. Of these 16 patients, 8 (group 1) were treated by anterior odontoid screw fixation, and 8 (group 2) by a posterior C1-2 arthrodesis. Results : Of the 8 patients in group 1, seven patients achieved solid bone fusion (87.5%), and one experienced screw back-out of the C-2 body two months after anterior screw fixation. All patients treated by posterior C1-C2 fusion in group 2 achieved successful bone fusion. Mean fracture displacements and fracture gaps were not significantly different in two groups. (p=0.075 and 0.782). However, mean fracture orientation angles were $15.3{\pm}3.2$ degrees in group 1, and $28.6{\pm}8.1$ degrees in group 2 (p=0.002), and mean fragment angulations were $3.2{\pm}2.1$ degrees in group 1, and $14.8{\pm}3.7$ degrees in group 2 (p=0.001). Conclusion : Even when the fracture lines of type II and rostral shallow type III fractures are oriented in an anterior oblique direction, anterior odontoid screw fixation can be feasible in carefully selected patients with a relatively small fracture orientation angle and relatively small fragment angulation.

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • 제23권3호
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.

후하악부 절개를 통한 하악골 관절돌기 골절의 치료 후 임상경과에 대한 고찰 (Consideration of Clinical Progress after Open Reduction with Retromandibular Approach in Treatment of Mandibular Condyle Fractures)

  • 김한구;권남호;배태희;김우섭
    • 대한두개안면성형외과학회지
    • /
    • 제9권1호
    • /
    • pp.17-22
    • /
    • 2008
  • Purpose: For several decades, open reduction has been a controversial issue in mandibular condyle fracture. The authors have successfully used the open reduction and internal fixation with retromandibular approach and have found it to be satisfactory for mandibular condyle fracture. Methods: A total of 10 patients with mandibular condyle fracture underwent open surgical treatment using retromandibular approach. The incision for the retromandibular approach was carried below the ear lobe and the facial nerve branches were identified. Dissection was continued until the fracture site was exposed and internal fixation was performed with miniplate following intermaxillary fixation. The average period of joint immobilization was 1 weeks and the arch bars were removed in 3 weeks on average. The preoperative and postoperative panoramic view and three-dimensional computed tomography were compared. During the follow up period, we evaluated the presence of malocclusion, chin deviation, trismus, pain, click sound, facial nerve palsy, hypertrophic scar and skin fistula. Results: According to the radiographic findings, the fractured condyle was reducted satisfactorily in all patients without any symptoms of facial palsy. During the follow up period ranged form 6 to 12 months, all clinical symptoms were improved except in one case with chin deviation and malocclusion. Conclusion: Using open reduction and internal fixation of mandibular condyle fracture with retromandibular approach, all results were satisfactory with good functional outcomes and minimal complication. We concluded that the open surgical treatment should be considered as the first choice for mandibular condyle fracture management.

Locking Compression Plate를 이용한 족근 관절 외과 골절의 치료 (Treatment of Fractures of the Lateral Malleolus using Locking Compression Plate)

  • 하성식;홍기도;정남식;심재천;안상천
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.99-104
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate usefulness of locking compression plate (LCP) as an open reduction technique by evaluating clinical results obtained from the patients with lateral malleolar fracture treated by internal fixation using LCP after open reduction. Materials and Methods: Among the patients with lateral malleolar fracture, the 28 patients who were treated by internal fixation using Locking compression plate after an open reduction and were able to be followed up for more than 6 months were included in this study. Final postoperative evaluation was done based on the Meyer's clinical and radiologic evaluation system. Results: All cases achieved anatomical reduction and fixation of the reduction postoperatively. 28 minutes were taken meaningly from the incision to the fixation of LCP plate after the anatomical reduction. Everage bony union time was 8.2 weaks, and the result was excellent in 23 cases (82%), good in 5 cases (17%) and poor result was abscent according to the criteria of Meyer et al. One case of post traumatic arthritis and one case of superficial infection on the operation site were found, but non-union, delayed union and malunion were not occurred. Conclusion: The internal fixation after open reduction using LCP is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including easy application and a greater stability due to its capability of maintaining exact anatomical reduction even though the screw does not penetrate the medial cortex of fibular to add the stability and rigidity of the fixation.

  • PDF

Comparison between Accurate Anatomical Reduction and Unsuccessful Reduction with a Remaining Gap after Open Reduction and Plate Fixation of Midshaft Clavicle Fracture

  • Kim, Joon Yub;Choe, Jung Soo;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • 제19권1호
    • /
    • pp.2-7
    • /
    • 2016
  • Background: The purpose of this study is to compare the radiological and clinical outcomes after open reduction and plate fixation of midshaft clavicle fractures between patients who achieved successful anatomical reduction and those who had a remaining fracture gap even after open reduction and plate fixation, and were thus treated with additional demineralized bone matrix (DBM). Methods: This retrospective analysis was conducted on 56 consecutive patients who underwent open reduction and internal fixation using a locking compression plate for acute displaced midshaft clavicle fractures, and who underwent radiographic and clinical outcome evaluations at least 6 months postoperatively. The outcomes between those who achieved perfect anatomical reduction without remnant gap (n=32) and those who had a remaining fracture gap even after open reduction and plate fixation treated with additional DBM (n=24) were evaluated. Results: There were no differences in the use of lag screws or wiring and operation time (all p>0.05) between those with and without remnant gap. No difference in the average radiological union time and clinical outcomes (satisfaction and Constant score) was observed between the two groups (all p>0.05). However, significantly faster union time was observed for AO type A fracture compared with other types (p=0.012), and traffic accident showed association with worse clinical outcomes compared with other causes of injury. Conclusions: Surgical outcome of midshaft clavicle fracture was more affected by initial fracture type and event, and re-reduction and re-fixation of the fracture to obtain a perfect anatomical reduction spending time appears to be unnecessary if rigid fixation is achieved.

Compression Osteosynthesis로 하악골골절을 치료한 경우 골절선상의 치아가 감염에 미치는 영향

  • 최병호;유재하;윤중호
    • 대한치과의사협회지
    • /
    • 제32권1호통권296호
    • /
    • pp.69-74
    • /
    • 1994
  • Fifty-one patients with fracture of mandible were treated by rigid internal fixation using AO Eccentric Dynamic Compression Plate. All teeth in the fracture line were left in all patients. None of patients were placed into maxillomancibular fixation. Two patients postoperatively developed infection (3.9%). The use of the AO EDCP for the fracture of mandible was found to be useful to prevent the infection, even permitting maintenance of the teeth in the line of fracture.

  • PDF

Comparative Analysis of the Result of Minimally Invasive Anterior Plating and Open Reduction and Internal Fixation in Humerus Shaft Simple Fracture

  • Ko, Sang-Hun;Choe, Chang-Gyu;Lee, Ju-Hyung
    • Clinics in Shoulder and Elbow
    • /
    • 제18권2호
    • /
    • pp.75-79
    • /
    • 2015
  • Background: This retrospective comparative study aims to evaluate the surgical outcomes and complications of two surgical methods for simple fractures of the humeral shaft; minimally invasive anterior plating and open reduction combined with internal fixation. Methods: A total of 26 patients with humeral shaft simple fractures, who had surgery between June 2009 and September 2013 and were followed-up at least 12 months, were included in our analysis. They were divided into two groups; group 1 comprised of 12 patients who underwent minimally invasive anterior plating and group 2 comprised of 14 patients who underwent an open reduction and internal fixation. The clinical outcomes, radiological results, and complications were compared and analyzed. Results: We found that bone union was achieved in all patients, and the mean union periods were $20.7{\pm}3.34$ and $20.3{\pm}3.91$ weeks for groups 1 and 2, respectively. In most patients, we found that shoulder and elbow functions were recovered. At 12 months post-operation, we found that the Korean Shoulder Scoring system, the University of California at Los Angeles score and Mayo elbow performance score were $91.4{\pm}7.97$, $33.4{\pm}1.15$, and $90.8{\pm}2.23$ for group 1, and $95.2{\pm}1.53$, $33.3{\pm}1.43$, and $90.17{\pm}1.85$ for group 2. In terms of complications, we found that 2 patients had radial nerve palsy after open reduction and internal fixation, but all cases spontaneously resolved within 6 months. Complications such as infection and loss of fixation were not reported. Conclusions: Both minimally invasive anterior plating and open reduction with internal fixation produced satisfactory outcomes in the treatment of simple fractures of the humeral shaft.

족관절 삼과 골절에 대한 치료 후 결과 비교 (Comparison of the Results after the Surgical Treatments of the Trimalleolar Ankle Fractures)

  • 라종득;박현수;임창석;장영수;박상원;정태원;전용수
    • 대한족부족관절학회지
    • /
    • 제8권1호
    • /
    • pp.86-91
    • /
    • 2004
  • Purpose: To evaluate the methods and results of the surgical treatment in the trimalleolar fracture of the ankle. Materials and Methods: We analysed the results of the ankle trimalleolar fracture which were treated with open reduction and internal fixation from January 1999 till September 2003. There were 45 patients who had at least six months follow up, 16 men, and 29 women. We have analysed the mechanism of injury, methods of operation and postoperative complications. Results: The results were assessed on ankle AP, lateral and mortise X-rays and retrospective chart review. There were 30 supination-external rotation, 13 pronation-external rotation, 2 pronation-abduction in the mechanism of injury by Lauge-Hansen classification. Cases of the posterior malleolar fracture which involved more than 25% of the weight bearing surface were 7 (15.6%). Medial malleolar mono-fixation was done in 5 cases, fibular mono-fixation in 2 cases, bimalleolar fixation in 32 cases, trimalleolar fixation in 6 cases. 38 cases (84.4%) were good or excellent in clincal assessment and 39 cases (86.7%) were good or excellent in radiological assessment according to the criteria of the Meyer. There was no difference of results among the surgical treatment methods. Conclusion: The results of our study indicate that the rigid fixation with early ankle motion and weight bearing is needed in ankle trimalleolar fracture. But minimal fixation is not bad in slight displaced fracture. Both anterior approach and posterior approach were useful methods to stabilization the posterior malleolar fracture. And pre-operative evaluation to detect the hidden soft tissue injuries and fracture mechanism is very important to avoid the failure.

  • PDF