• 제목/요약/키워드: fracture detection

검색결과 174건 처리시간 0.029초

Delayed Traumatic Diaphragm Hernia after Thoracolumbar Fracture in a Patient with Ankylosing Spondylitis

  • Lee, Hyoun-Ho;Jeon, Ikchan;Kim, Sang Woo;Jung, Young Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권2호
    • /
    • pp.131-134
    • /
    • 2015
  • Traumatic diaphragm hernia can occur in rare cases and generally accompanies thoracic or abdominal injuries. When suffering from ankylosing spondylitis, a small force can develop into vertebral fracture and an adjacent structural injury, and lead to diaphragm hernia without accompanying concomitant thoracoabdominal injury. A high level of suspicion may be a most reliable diagnostic tool in the detection of a diaphragm injury, and we need to keep in mind a possibility in a patient with ankylosing spondylitis and a thoracolumbar fracture, even in the case of minor trauma.

엔드밀 가공시 절삭력과 절삭유를 통해 전파된 음향방출을 이용한 공구파손 검출 (Tool fracture detection in end milling using cutting force and acoustic emission propagated through cutting fluid)

  • 맹민재;조성산;정준기
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.163-170
    • /
    • 1997
  • End milling experiments are conducted to investigate characteristics of acoustic emission (AE) and cutting force singals due to tool fracture. The AE signals are obtained with a sensor attached to cutting fluid discharge nozzle. Tool states are identified with scanning electron microscopy and optical microscopy. It is demonstrated that the AE signals provide reliable informations about the cutting processes and tool states. Morever, tool fracture can be detected successfully using both the AE count rate and the standard deviation of principal cutting force.

  • PDF

자기진단 CPGFRP의 파괴예측기능 평가를 위한 콘크리트 적용실험 (Evaluation of Fracture Detection Function for the Concrete by Self-Diagnosis CPGFRP)

  • 최현수;박진섭;정민수;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.27-31
    • /
    • 2003
  • To maintain serviceability of concrete structure more than proper it is necessary not only predict service life through periodical monitor but also need monitoring system to recognize optimal time and method for repair. Recently, CPGFRP, replacing some GFRP with CF, is developed and used for monitoring concrete fraction. But dramatic resistance change of CPGFRP is showed below 0.5% strain and it is not small strain in terms of monitoring micro crack in concrete. In other word, monitoring with CF is not suitable in low stress hut hight stress. In this study, we accessed applicable possibility and reliability of CPGFRP composite as monitoring sense that is proved very sensitive to stress through domestic and oversea previous study. CPGFRP composite plays a role in specimen like steel and increases flexural strength. CPGFRP composite shows resistance increasement in micro crack. In particular, CPUFRP is more sensitive than strangage in low stress. Resistance change ratio curve is very similar to strain curve so sensitivity and reliability is very excellent to monitor concrete fracture.

  • PDF

자기진단 CPGFRP의 파괴예측기능 평가를 위한 콘크리트 적용실험 (Evaluation of Fracture Detection Function for the Concrete by Self-Diagnosis CPGFRP)

  • 최현수;박진섭;정민수;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.27-31
    • /
    • 2003
  • To maintain serviceability of concrete structure more than proper it is necessary not only predict service life through periodical monitor but also need monitoring system to recognize optimal time and method for repair. Recently, CPGFRP, replacing some GFRP with CF, is developed and used for monitoring concrete fraction. But dramatic resistance change of CPGFRP is showed below 0.5% strain and it is not small strain in terms of monitoring micro crack in concrete. In other word, monitoring with CF is not suitable in low stress but hight stress. In this study, we accessed applicable possibility and reliability of CPGFRP composite as monitoring sense that is proved very sensitive to stress through domestic and oversea previous study. CPGFRP composite plays a role in specimen like steel and increases flexural strength. CPGFRP composite shows resistance increasement in micro crack. In particular, CPGFRP is more sensitive than strangage in low stress. Resistance change ratio curve is very similar to strain curve so sensitivity and reliability is very excellent to monitor concrete fracture.

  • PDF

회전 경계박스 기능의 변형 FASTER R-CNN 딥러닝 알고리즘을 이용한 암석 CT 영상 내 자동 균열 탐지 (Automatic Fracture Detection in CT Scan Images of Rocks Using Modified Faster R-CNN Deep-Learning Algorithm with Rotated Bounding Box)

  • 추엔 팜;장리;염선;신휴성
    • 터널과지하공간
    • /
    • 제31권5호
    • /
    • pp.374-384
    • /
    • 2021
  • 본 논문에서는 암석시료의 CT 촬영 이미지상의 균열을 자동으로 탐지하는 새로운 인공지능 딥러닝 기법을 제안한다. 본 제안 기법은 2단계 딥러닝 객체인식 알고르즘인 Faster R-CNN을 기반으로 회전 가능한 경계박스(bounding box) 개념을 도입하여 알고리즘을 개조하였다. 회전 경계박스의 도입은 관심 균열 영역 밖의 배경의 불균질성 및 균열의 크기와 형태에 영향을 받는 딥러닝 객체인식기법 상의 고유한 어려움을 극복하기 위한 핵심 역할을 한다. 본 회전형 경계박스의 사용은 일반적으로 사용되는 영상 수평축과 평행한 경계박스 사용의 경우와 비교하여 긴 형태의 균열 형상 특성에 매우 잘 부합된다. 즉, 좋지않은 영향을 끼치는 경계박스 내 균열 이외 배경영역의 비율을 최소화 시킬 수 있다. 이외에도, 회전 경계박스의 추가적인 이점은 인식된 균열의 방향에 따라 회전하여 추론되는 경계박스를 통해 균열의 방향과 길이에 대한 정보를 직접적으로 얻을 수 있다. 본 제안기법의 적용성을 검증하기 위하여, 이미지상에서 매우 불균질한 화강암 시료에 인공적으로 균열을 발생시킨 다수의 암석시료 영상을 딥러닝 학습에 사용하고 추론 성능 실험을 진행하였다. 그 외에도, 동일 조건에서 사암과 셰일 암석 시료에도 적용하여 검증하였다. 결론적으로, 제안된 기법을 통해 균열 객체 인식의 평균 추론정확도(mAP)값이 0.89 정도 수준의 우수한 추론 성능을 보였으며, 기존 기법에 비해 추론된 경계박스 내 균열과 배경 영역의 비율 측면에서 배경의 비율이 획기적으로 최소화되는 유리한 추론 검증 결과를 보였다.

Acoustic Emission 의 섬유파단 Source Location을 이용한 Carbon Fiber/Epoxy Composites의 계면특성 및 비파괴적 평가 (Interfacial and Nondestructive Evaluation of Single Carbon Fiber/Epoxy Composites by Fiber Fracture Source Location using Acoustic Emission)

  • Kong, Jin-Woo;Kim, Jin-Won;Park, Joung-Man;Yoon, Dong-Jin
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 추계학술발표대회 논문집
    • /
    • pp.116-120
    • /
    • 2001
  • Fiber fracture is one of the dominant failure phenomena to determine total mechanical properties in composites. Fiber fracture locations were measured by optical microscopic method and acoustic emission (AE) as functions of matrix toughness and surface treatment by the electrodeposition (ED), and then two methods were compared. Two AE sensors were attached on the epoxy specimen and fiber fracture signals were detected with elapsed time. The interfacial shear stress (IFSS) was measured using tensile fragmentation test and AE system. In ED-treated case, the number of the fiber fracture measured by an optical method and AE was more than that of the untreated case. The signal number measured by AE were rather smaller than the number of fragments measured by optical method, since some fiber fracture signals were lost while AE detection. However, one-to-one correspondence between the x-position location by AE and real break positions by optical method was generally established well. The fiber break source location using AE can be a valuable method to measure IFSS for semi- or nontransparent matrix composites nondestructively (NDT).

  • PDF

종골 골절과 동반된 비골건 탈구(6예보고) (Peroneal Tendon Dislocation associated with Calcaneal Fracture (Six Cases Report))

  • 차승도;김형수;정수태;박재형;김주학;염주상;이창현
    • 대한족부족관절학회지
    • /
    • 제12권2호
    • /
    • pp.210-215
    • /
    • 2008
  • Peroneal tendon dislocation in association with calcaneal fracture is not common and difficult to diagnose and is often overlooked. It can result in peroneal tendon tear and tenosynovitis which in turn lead to ankle pain and dysfunction. Early detection with through physical examination and CT scan is important to reduce the subsequent tendon dysfunction. We experienced 6 cases of peroneal tendon dislocation associated with calcaneal fracture, and treated 3 of them at the time of fracture operation and treated the other 3 after calcaneal fracture surgery due to sustained pain. We report the results with a review of the literature.

  • PDF

외상과 다수의 치아 파절을 동반한 골격성 II 급 부정교합 환자의 치험례 (Post-traumatic reconstruction of skeletal Class II malocclusion with multiple teeth fracture)

  • 장우원;백의선;황순신;김경호;정주령
    • 대한구순구개열학회지
    • /
    • 제20권1호
    • /
    • pp.49-58
    • /
    • 2017
  • We report the rehabilitation of Class II malocclusion with multiple teeth fracture due to trauma. A multidisciplinary team approach was necessary to treat patient's problems such as bone fracture, malocclusion, and multiple teeth fracture. Emergency conservative treatment, orthodontic treatment and prosthetic restoration successfully restored the occlusion. However, special considerations were needed along the orthodontic treatment process due to the unexpected complications such as ankylosis, root resorption and detection of additional teeth fractures.

밀링 공구마멸과 치핑의 검출을 위한 음향방출 이용에 관한 연구 (A Study on the Application of Acoustic Emission Measurement for the In-process Detection of Milling Tools' Wear and Chipping)

  • 윤종학;강명순
    • 비파괴검사학회지
    • /
    • 제11권1호
    • /
    • pp.31-37
    • /
    • 1991
  • Acoustic emission(AE) signals detected during metal cutting were applied as the experimental test to sensing tool wear and chipping on the NC vertical milling machine. The in-process detection of cutting tool wear including chipping, cracking and fracture has been investigated by means of AE in spite of vibration or noise through intermittent metal cutting, then the following results were obtained 1) When the tool wear is increased suddenly, or the amplitude of AE signals changes largely, it indicates chipping or breaking of the insert tip. 2) It was confirmed that AE signal is highly sensitive to the cutting speed and tool wear. 3) At the early period of cutting, the wear were large and RMS value increased highly by the influence of minute chipping and cracking, etc. Therefore, the above situations should be considered for the time when the tool would be changed.

  • PDF

저하중용 자기진단 GFRP의 제조와 특성 (Fabrication and Properties of Self-diagnosis GFRP for Low Loading)

  • 신순기;임현주;이준희
    • 한국재료학회지
    • /
    • 제13권11호
    • /
    • pp.732-736
    • /
    • 2003
  • A CP-GFRP(Carbon Powder-Glass Fiber Reinforced Plastic) sensor was fabricated for fracture detection. The electric resistance of the sensor was measured on condition of various composition of carbon powders and thickness of bundle of glass fibers. The resistance of the sensor was decreased as the increase of the content of carbon powders and the TEX of the glass fibers. In the case of loading on CP-GFRP, because inner crack was propagated, the part of percolation structures was disconnected. These observations show the following results. The conduction of CP-GFRP sensor is due to percolation structure of carbon powders and increase of resistance is due to expansion of cracks.