• Title/Summary/Keyword: fractional error

Search Result 119, Processing Time 0.024 seconds

470-MHz-698-MHz IEEE 802.15.4m Compliant RF CMOS Transceiver

  • Seo, Youngho;Lee, Seungsik;Kim, Changwan
    • ETRI Journal
    • /
    • v.40 no.2
    • /
    • pp.167-179
    • /
    • 2018
  • This paper proposes an IEEE 802.15.4m compliant TV white-space orthogonal frequency-division multiplexing (TVWS)-(OFDM) radio frequency (RF) transceiver that can be adopted in advanced metering infrastructures, universal remote controllers, smart factories, consumer electronics, and other areas. The proposed TVWS-OFDM RF transceiver consists of a receiver, a transmitter, a 25% duty-cycle local oscillator generator, and a delta-sigma fractional-N phase-locked loop. In the TV band from 470 MHz to 698 MHz, the highly linear RF transmitter protects the occupied TV signals, and the high-Q filtering RF receiver is tolerable to in-band interferers as strong as -20 dBm at a 3-MHz offset. The proposed TVWS-OFDM RF transceiver is fabricated using a $0.13-{\mu}m$ CMOS process, and consumes 47 mA in the Tx mode and 35 mA in the Rx mode. The fabricated chip shows a Tx average power of 0 dBm with an error-vector-magnitude of < 3%, and a sensitivity level of -103 dBm with a packet-error-rate of < 3%. Using the implemented TVWS-OFDM modules, a public demonstration of electricity metering was successfully carried out.

An Excess-3 Code Carry Lookahead Design for High-Speed Decimal Addition (고속 십진 가산을 위한 3초과 코드 Carry Lookahead설계)

  • 최종화;유영갑
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.40 no.5
    • /
    • pp.241-249
    • /
    • 2003
  • Carry lookahead(CLA) circuitry of decimal adders is proposed aiming at delay reduction. The truncation error in calculation of monetary interests may accumulate yielding a substantial amount of errors. Binary Coded Decimal(BCD) additions. for example, eliminate the truncation error in a fractional representation of decimal numbers. The proposed BCD carry lookahead scheme is aiming at the speed improvements without any truncation errors in the addition of decimal fractions. The delay estimation of the BCD CLA is demonstrated with improved performance in addition. Further reduction in delay can be achieved introducing non-weighted number system such as the excess-3 code.

A System Development, Performance Assessment, and Service Implementation of ATM-based High-rate Digital Subscriber Line (HDSL) (ATM 기반 HDSL 개발, 동 선로 상의 성능 평가 및 서비스 구현)

  • 양충열
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1562-1574
    • /
    • 1998
  • We, in this paper, have implemented T1, E1 and fractional E1 HDSL(High-bit-rate digital subscriber line) function over an ATM switching system. The maxi$\mu$ loop lengths for subscriber service and cell loss rates to meet the bit error rate of 10$^{-7}$ at transmission of 2B1Q HDSL data E1 rate over existing telephone copper wires in the presence of the significant impairments such as NEXT(Nearned crosstalk), impulse noise, power line noise and longitudinal over the CSAs environment consisting of 26 gauge and 25 gauge unloaded copper telephone lines has assessed. HDSL will intially be used to serve private-DS1, ISDN-BRA, and DLC feeders, later DS1 extension from optic fiber cable. We also present market provision for the HDSL.

  • PDF

Timing Synchronization with Channel Impulse Response in OFDM Systems (채널 임펄스 응답을 이용한 OFDM 시스템 시간 동기)

  • Kang, Eun-Su;Han, Dong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.53-58
    • /
    • 2007
  • OFDM (orthogonal frequency division multiplexing) is an effective modulation technique for high speed transmission over fading channels. However, it has a high bit error rate in the receiver if there is an error on frame synchronization because of phase rotation. A coherent OFDM system has to acquire exact timing synchronization of fraction and integer sampling positions. When a sampling offset exist the performance of a receiver will be degraded severely. In this paper, we propose an algorithm that acquires the fractional sampling offset in OFDM systems. This scheme compares the channel impulse responses with the early and late sampled signals having 0.5 sample offset from the estimated sampling positions by correlation with the received and training samples. Its performance is verified by computer simulations in multipath channels.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Performance of ISC model-Predicting short-term concentrations around waste incinerator plant (ISC모델의 적용성 평가 - 소각장 주변지역의 단기농도예측)

  • 정상진
    • Journal of Environmental Science International
    • /
    • v.12 no.7
    • /
    • pp.809-816
    • /
    • 2003
  • The short-term version of Industrial Source Complex Model(ISCST3) was evaluated for estimating short-term concentrations using criteria pollutant(SO$_2$, NO$_2$, CO, PM10) data from emission inventory of Young Tong area in Suwon for the year 2002. The contribution of pollutant concentration from point, line, area sources was found 21.8, 76.5 and 1.6%. Statistical parameters, such as correlation coefficient, index of agreement(IA), normalized mean square error(NMSE) and fractional bias(FB) were calculated for each pollutants. The model performance were found good for PM10(82%) and NO$_2$(69%), but poor for SO$_2$(34%) and CO(13%).

On Numerical Computation of Pickands Constants

  • Choi, Hyemi
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.3
    • /
    • pp.277-283
    • /
    • 2015
  • Pickands constant $H_{\alpha}$ appears in the classical result about tail probabilities of the extremes of Gaussian processes and there exist several different representations of Pickands constant. However, the exact value of $H_{\alpha}$ is unknown except for two special Gaussian processes. Significant effort has been made to find numerical approximations of $H_{\alpha}$. In this paper, we attempt to compute numerically $H_{\alpha}$ based on its representation derived by $H{\ddot{u}}sler$ (1999) and Albin and Choi (2010). Our estimates are compared with the often quoted conjecture $H_{\alpha}=1/{\Gamma}(1/{\alpha})$ for 0 < ${\alpha}$ ${\leq}$ 2. This conjecture does not seem compatible with our simulation result for 1 < ${\alpha}$ < 2, which is also recently observed by Dieker and Yakir (2014) who devised a reliable algorithm to estimate these constants along with a detailed error analysis.

Neural Network Modeling of Charge Concentration of Thin Films Deposited by Plasma-enhanced Chemical Vapor Deposition (플라즈마 화학기상법을 이용하여 증착된 박막 전하 농도의 신경망 모델링)

  • Kim, Woo-Serk;Kim, Byung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.108-110
    • /
    • 2006
  • A prediction model of charge concentration of silicon nitride (SiN) thin films was constructed by using neural network and genetic algorithm. SIN films were deposited by plasma enhanced chemical vapor deposition and the deposition process was characterized by means of $2^{6-1}$ fractional factorial experiment. Effect of five training factors on the model prediction performance was optimized by using genetic algorithm. This was examined as a function of the learring rate. The root mean squared error of optimized model was 0.975, which is much smaller than statistical regression model by about 45%. The constructed model can facilitate a Qualitative analysis of parameter effects on the charge concentration.

  • PDF

A Subgrid scale model with a 3 -dimensional explicit filtering (3차원 외재적 필터링 을 이용한 SGS 모델)

  • Lee, Kyung-Seh;Baek, Je-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.634-637
    • /
    • 2008
  • A large eddy simulation with an explicit filter on unstructured mesh is presented. The flow filed is semi-implicitly marched by a fractional step method. Spatial discretization of the solver is designed to guarantee the second order accuracy. An isotropic explicit filter is adopted for measuring the level of subgrid scale velocity fluctuation. The filter is linearity-preserving and has second order commutation error. The developed subgrid scale model is basically eddy viscosity model which depends on the explicitly filtered fields and needs no additional ad hoc wall treatment, such as van Driest damping function. For the validation, the flows in a channel and a pipe are calculated and compared to experimental data and numerical results in the literature.

  • PDF

Performance Comparison for MODEM in MUltipath Fading Channel (다중경로 페이딩 채널에서의 변복조 성능비교)

  • 전동근;박형근;이연우
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.28-34
    • /
    • 1998
  • 미래 개인 휴대통신에서는 고속의 데이터 서비스를 위하여 높은 대역폭 효율을 요 구하게 된다. 무선통신 서비스를 향상시키기 위하여 코딩기법, 변조기법, 다중화기법 등의 다양한 방법이 연구되고 있다. 이중에서 특히 변조기법은 시스템의 성능을 결정하는 중요한 요소가 된다. 본 논문에서는 PSK. OQPSK, π/4 DQPSK, MSK, GMSK의 다섯가지 변조기 법에대한 BER성능을 시뮬레이션하였다. 시뮬레이션을 위한 다중경로 페이딩채널로서 3가지 서로 다른 채널을 적용하였다. 이때 시뮬레이션을 위하여 1.544Mbps의 전송속도와 1.9GHz 의 반성주파수 환경을 고려하였다. 또한 fractional 선형 등화기를 적용하여 변조방식에 따른 성능향상 정도를 비교하였다. 채널 Ⅰ, Ⅱ, Ⅲ에 대해 각각 30dB, 20dB, 10dB 정도에서 error floor현상이 발생했으며 π/4 DQPSKS가 가장 낮은 BER 특성을 보인 반면 QPSK는 가장 높은 BER을 나타냈다. 등화기를 적용했을 때는 GMSK의 성능향상이 가장 크게 나타 났다.

  • PDF