• 제목/요약/키워드: forced evaporation

검색결과 24건 처리시간 0.042초

가열된 평판위에 매달려 있는 액적의 음향공진에 의한 열 및 물질 전달 촉진에 관한 연구 (Heat and Mass Transfer Enhancement of a pendant droplet on heated horizontal surface by acoustic resonance)

  • 문종훈;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.335-340
    • /
    • 2005
  • Nonlinear and forced oscillations of supported viscous droplet were focused in the present study. The droplet has a free contact line with solid plate and inviscid fluid. Natural frequencies of a pendant droplet have been investigated experimentally by imposing the acoustic wave while the frequency is being increased at a fixed amplitude. The evaporation was observed at atmosphere pressure. The droplet was recorded throughout the entire evaporation process and transient variations of the volume was measured. The evaporation process of oscillating droplet with thermofoil has been also observed to investigate analyzing the resonance effect on the thermal characteristics of droplet. It is found that a pendant droplet shows the resonant behaviors at each mode similar to the theoretical analysis. During imposing the acoustic wave, the pendant droplet makes a rotating motion in its longitudinal axis which is a new shape oscillation mode. The evaporation rate of a pendant droplet at resonant frequency is significantly enhanced.

  • PDF

수평증발관내 R22/R114 혼합냉매의 열전달 특성에 관한 연구 (A Study for Evaporation Heat Transfer Characteristic of R22/Rl14 Refrigerant Mixtures in a Horizontal Tube)

  • 윤치한;이종인;하옥남
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.502-510
    • /
    • 2000
  • Evaporation heat transfer characteristics were studied in a horizontal tube using R22/R114 non-azotropic refrigerant mixture. the heat transfer coefficient was high in the upper part for pure refrigerants, and heat transfer coefficient was low in the lower part for refrigerant mixtures. In the low quality region where nucleate boiling was dominant, the average heat transfer coefficient was low. In the region where forced convection was dominant, heat transfer coefficient was high. Results show that the heat transfer coefficient for pure refrigerants obtained by experiments were lower than those of Yoshida et al. but agreed well with Jung et al., and Chen et al. data. But the heat transfer coefficients for refrigerant mixtures were lower about 20% than those predicted by the equation for pure refrigerant.

  • PDF

수평관내 3성분 혼합냉매의 강제대류비등 열전달 (Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube)

  • 오종택
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF

스팀 에젝터에 의한 강제 증발 방식의 냉각 특성에 관한 연구 (Study on Cooling Charcteristics of Forced Evaporation by using Steam Ejector)

  • 손호재;이윤환;김영근;정효민
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.41-46
    • /
    • 2006
  • This study shows a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water by about $5^{\circ}C\;from\;25^{\circ}C$ or higher. In this research, to replace the present water cooling system, we focused on a water cooling system by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are depended on the vacuum pressure in the enclosed tank, and the cooling water is generated by latent head of evaporation. As the experimental results, the absolute vacuum pressure obtained was about $5{\sim}8$ mmHg using a steam driven ejector with jet condenser.

  • PDF

해염성분에 의한 에어로솔 물성변화 모사연구 (A Modeling Study on Aerosol Property Changes due to Sea-Salts)

  • 김용표
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.113-120
    • /
    • 2000
  • Effects of sea-salts on the properties of aerosol collected in a coastal region were studied by applying a gas-particle equilibrium model SCAPE to the measurement data from Korea Cheju Island in summer 1994. It was found that the observed higher ammonium concentrations in fine particles (PM2.5) than in TSP were caused by forced evaporation of ammonium in coarse fraction of aerosol by sea-salts and the degree of evaporation was quantified through an application of SCAPE. By subtracting the sea-salt fraction from the measured concentra-tions the changes of aerosol property were also studied. The concentrations of nitrate at both TSP and PM2.5 decreased when alkaline sea-salt fraction was removed from the measured data. Estimates of aerosol acidity increased for most samples with sea salt loadings, However in some cases with high mass fractions of sea-salt components the aerosol acidity of PM2.5 decreased slightly. This is though to be related with the formation of solid salt with the removal of sea-salts.

  • PDF

전자선 증착기술에 의해 성장된 다결정 CdSe 박막의 광학적 특성 (Optical properties of the polycrystalline CdSe thin films grown by the electron-beam evaporation technique)

  • 김화민
    • 한국진공학회지
    • /
    • 제9권1호
    • /
    • pp.60-68
    • /
    • 2000
  • The optical constants ($E_g^d$, n, K) of the polycrystalline CdSe thin films deposited on the glass substrate by the electron-beam evaporation technique are determined over 400~2,500 nm photon wavelengths. In order to explain the variation of the optical contents with film thickness and substrate temperatures, the surface microstructural parameter are investigated by AFM (atomic forced microscope( images for the films deposited by different growth conditions. It is shown that the variations of optical constants are close related to changes of the surface morphology of the CdSe thin films. The decrease in the band gap with film thickness is connected with quantum size effects due to increase of the grain size. The refractive index of CdSe films decrease with increasing the grain size of the films, and the dispersion of the refractive index followed a single oscillator model according to the Sellmeier formulation.

  • PDF

증발에 따른 붕소의 탈비말 동반 (De-entrainment of Boron by Evaporation.)

  • Lee, Hoo-Kun;Chun, Kwan-Sik;Park, Hyun-Soo;Suh, In-Suk
    • Nuclear Engineering and Technology
    • /
    • 제18권4호
    • /
    • pp.261-266
    • /
    • 1986
  • 원자력발전소에서 사용되고 있는 증발기에 대해 boron의 탈비말 동반을 분석하기 위하여 강제순환식 및 반연속식 증발기가 실험에 사용되었다. 보수가 용이하고 제염효율이 높은 Cyclone과 glass-wool 충전탑을 액체방사성폐기물을 처리하는데 탈비말동반장치로 사용되었다. Cyclone과 glass-wool 충전탑을 연결하여 사용하였을 때 붕소에 대한 제염효율은 1,000 이상을 나타내었다.

  • PDF

Plasma-PVD법에 의해 제작한 Zn-Mg합금 박막의 특성 분석 (Properties Analysis of Zn-Mg Alloy Thin Films Prepared by Plasma Enhanced PVD Method)

  • 이경희;배일용;김여중;문경만;이명훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.194-195
    • /
    • 2005
  • (100-x)Zn xMg alloy films are prepared onto cold-rolled steel substrates; where x ranged from 0 to about 38 atomic %. The alloy films show microcrystalline and grain structures respectively, according to preparation conditions such as composition ratio of zinc and magnesium or gas pressures etc.. And X-ray diffraction analysis indicates not only the presence of Zn-Mg thin films with forced solid solution but also the one of $MgZn_2$ alloy films partly. In addition the influence of Mg/Zn composition ratio and morphology of the Zn-Mg alloy films on corrosion behavior is evaluated by electro-chemical anodic polarization tests in deaerated 3% NaCl solution. From this experimental results, all the prepared Zn-Mg alloy films showed obviously good corrosion resistance to compare with 99.99% Zn and 99.99% Mg Ingots for evaporation metal. It is thought that the Zn-Mg films with effective forced solid solution prepared by plasma enhanced PVD method, produces smaller and denser grain structure so that may improve the formation of homogeneous passive layer in corrosion environment.

  • PDF

증발을 이용한 방사성 액체폐기물의 처리와 피폭선량평가 (Treatment of Radioactive Liquid Waste Using Natural Evaporator and Resulted Exposure Dose Assessment)

  • 정경환;박승국;김은한;정기정;박현수
    • Journal of Radiation Protection and Research
    • /
    • 제24권2호
    • /
    • pp.101-108
    • /
    • 1999
  • 극저준위 방사성액체폐기물 처리를 위하여 공기의 온도와 습도 및 유입 공기의 속도에 따른 증발량의 관계를 천을 이용한 강제증발실험 장치로 실험하였다. 그 결과 각각의 변수와 증발량의 상관관계를 실험식으로 도출하였다. 또한 Cs-137 을 함유한 모의폐액을 사용하여 본 장치에 대한 제염 계수를 얻은 결과 $DF=10^4$으로 나타났다. TRlGA Mark II & III 연구용 원자로 폐로시 발생되는 극저준위 방사성액체폐기물을 증발장치로 처리할 때 주변의 일반개인에 대한 연간 피폭선량을 보수적으로 평가한 결과, 유효선량 (effective dose)은 $1.01{\times}10^{-3}mSv$이고, 환경으로 배출되는 공기의 방사능 농도(Cs-137)는 $4.637{\times}10^{-14}\;{\mu}Ci/cc$ air 이다. 따라서 극저준위 방사성액체폐기물의 처리를 위하여 강제증발장치를 사용하는 것은 주민에 아무런 영향이 없음을 알 수 있었다.

  • PDF

공기유입시스템에서의 섬유매체에 의한 방사성액체폐기물 처리에 관한 연구 (A Study on the Treatment of Radioactive Liquid Wastes using Synthetic textile by Air Intake System)

  • 김태국;이영희;안섬진;손종식;홍권표
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.101-104
    • /
    • 2003
  • 저준위 방사성액체폐기물 처리방법으로 에너지 소모가 적은 경제적이고 효율적인 처리방법을 제시하기 위하여 면 과 Polyester 가 함유된 합성섬유를 증발매체로 하여 자연기상 상태의 건조한 공기를 유입하여 방사성 액체폐기물과 접촉시켜 증발하는 연구를 하였다. 본 연구에서는 자연상태의 공기를 강제 유입시켜 액체의 증발현상, 증발매체표면에서의 물질전달 등 이론을 토대로 방사성액체폐기물을 처리하는 연구를 수행하였다. 실험은 방사성폐액을 직접 사용하였으며, 증발에 영향을 미치는 변수에 따라 증발 단위 면적당 방사성 폐액의 증발량측정 및 제염계수를 조사하였다. 증발효과는 유입공기의 습도가 낮고 공기의 유속과 공급액의 유량이 증가하고 폐액의 온도가 높아질수록 증발량이 증가하였다. 실험결과 습도는 70% 이하, 공급폐액의 유량이 $3.4{\ell}/hr\cdotm^2$ 이상, 공기유속은 1.14~l.47 m/sec 범위가 조업조건이며, 이때 제염계수는 $5.1{\times}10^3$, 배출공기의 방사능 농도는 $4.7{\times}10^{-13}{\mu}Ci/\textrm{m}{\ell}{\cdot}air$로 측정되었다. 공급유량이 $4.6{\ell}/hr\cdotm^2$와 공기유속이 1.47 m/sec일때 최대 증발조건으로 확인되었으며 대기의 온.습도 및 풍속에 따른 실험을 통하여 달톤형의 증발식 Air factor $[\textit{Eh}=(0.018 + 0.0141\textitv) {\delta}textitH]$를 도출하였다.

  • PDF