• Title/Summary/Keyword: forced cooling

Search Result 203, Processing Time 0.027 seconds

Verification Experiment and Simulation of Cooling Load for a Test Space with Forced Ventilation (시험공간에 강제환기를 고려한 냉방부하의 실증실험 및 시뮬레이션)

  • Kim, Dong-Hyeok;Yoo, Ho-Seon;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.217-222
    • /
    • 2005
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8:30 to 21:00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual cooling loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Cooling loads including sensible and latent were compared between by experiment and by simulation. Both of cooling loads associated with ventilation show a close agreement within an engineering tolerance.

  • PDF

Design and Application of Forced Cooling System in Steam Turbine (증기터빈 강제냉각 장치의 설계 및 적용)

  • 김효진;류승우;강용호
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.9
    • /
    • pp.25-32
    • /
    • 1998
  • The forced cooling system is designed to shorten the overhaul time of steam turbine, which is important in view of economic concern of utility companies, Forced cooling of the hot turbine is achieved by suction of air flow into the turbine after the turbine shuts down. The heat transfer process by suction of air flow can cause thermal stress due to the thermal gradients. In this paper, the analysis of heat transfer is performed to calculate the air flow rate. Based on the prediction of cyclic fatigue damage and the experience, the cooling equipment is designed for shortening the cooling time of steam turbine.

  • PDF

A Study on the Heat Sink with internal structure using Peltier Module In the Natural and Forced Convection (자연대류와 강제대류에서 펠티에 소자를 이용한 내부터널 구조를 가지는 히트싱크에 관한 연구)

  • Lee, Min;Kim, Tae-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4072-4080
    • /
    • 2014
  • The Peltier Module has been used to dissipate the heat from electronic devices and electronic components. In this module, a heat sink is used to release the operating heat into the air outside. This study addressed the heat transfer characteristics for a heat sink with an inner tunnel. Under forced and natural convection conditions, the heat transfer characteristics were different. Therefore, the cooling and heating performances were studied for the heat sink, which has an inner tunnel. The heat transfer conditions were also evaluated by performing an experimental test, which investigated the heat transfer characteristics related to the variance in time and temperature distribution. Experiments on the heat transfer characteristics of the heat sink were conducted based on the forced and natural convection and temperature distribution changes. In the cooling experiment, the A- and B-shaped cooling pin heat sinks decreased the temperature of the forced convection than the temperature of natural convection. In the forced and natural convection, the A- and B-shaped decreased to a minimum of $-15^{\circ}C$. Under the forced and natural convection conditions, A- and B-shaped cooling pin heat sinks decreased the temperature when the voltage was increased. In the heating experiment, the A- and B-shaped cooling pin heat sinks increased the temperature of the forced convection than the temperature of natural convection. In forced convection, when the voltage was $15^{\circ}C$, the temperature of the A-shaped cooling pin heat sink increased to $150^{\circ}C$, and the temperature of the B-shaped cooling pin heat sink increased to $145^{\circ}C$. Under forced and natural convection conditions, the A- and B-shaped cooling pin heat sinks showed an increase in temperature with increasing voltage.

Correlation of Droplet Flow Rate and Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region (강제대류 및 핵비등영역에 있어서 액적유량과 분무냉각 열전달의 상관관계에 관한 연구)

  • Kim, Yeung-Chan
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.143-148
    • /
    • 2008
  • In the present study, the correlation between the Nusselt number and Reynolds number was developed for forced convection and nucleate boiling region in spray cooling. Also the effect of droplet subcooling on spray cooling heat transfer was investigated. Full cone spray nozzles were employed for spray cooling experiment, and water and FC-77 were used for developing the correlation. From the experimental results, the correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30%$ error for water and FC-77.

  • PDF

A Study on the Characteristic of the Thermal Environment in the Cooling System at the Apartment (공동주택 거실의 냉방방식에 따른 열환경 특성에 관한 연구)

  • 이무진
    • Journal of the Korean housing association
    • /
    • v.10 no.4
    • /
    • pp.111-120
    • /
    • 1999
  • The purpose of this study is to evaluate the efficiency of the thermal environment created by the cooling system at the apartment that combines the forced convection cooling(the system reducing humidity from room) with the floor cooling radiation which uses the floor panel from floor heating system, a general residential heating system in Korea. In this study, the combined cooling system in which air supply, spurt temperature difference and interior draft are reduced, is compared with the existing forced convection cooling system. To identify the effect of the comparison concretely, a comparative experiment is carried out on tour conditions, ie, convection cooling, floor radiation convection cooling and floor radiation cooling. Through it the characteristical thermal environment formed within the model room is analyzed, and the conveying system of compressed floor chill and condensation problem are reviewed.

  • PDF

A Study on Enhancement of Thermoelectric Cooling System Performance by Piezoelectric Actuator (압전 액츄에이터를 이용한 열전냉각 시스템 성능 향상에 관한 연구)

  • Yang, Ho-Dong;Yoon, Hee-Sung;Oh, Yool-Kwon
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.13-19
    • /
    • 2009
  • The thermoelectric cooling system consisted of the thermoelectric module, a heat sink and a cooling fan, respectively. Also, the piezoelectric actuator was applied to improve the performance of thermoelectric cooling system and investigate the heat transfer phenomenon. The temperature distribution of test section was measured to investigate cooling characteristics of thermoelectric cooling system. The flow phenomenon of test section was visualized using visualization device. When the piezoelectric actuator was applied to the heat transfer process of thermoelectric cooling system, acoustic streaming was occurred in test section. The acoustic streaming was occurred forced convection flow, and was regularly formed the temperature distribution in test section. The results clearly show that the acoustic streaming is one of the prime effects to enhance the convection heat transfer and can enhance the performance of thermoelectric cooling system.

Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation (강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험)

  • Kim, Dong-Hyuk;Hong, Hi-Ki;Yoo, Ho-Seon;Kim, Ook-Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.

Effect of Precooling Treatments on the Storability of Chicon during MA Storage (예냉 처리가 치콘의 MA 저장성에 미치는 영향)

  • Jung, Hyun-Jin;Seo, Hyun-Taek;Choi, In-Lee;Yoo, Tae-Jong;Son, Jin-Sung;Won, Jae-Hee;Kim, Il-Seop;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.360-365
    • /
    • 2010
  • The effects of precooling treatments on the storability of chicon were investigated during modified atmosphere (MA) storage. The forced air cooling showed faster precooling rate that reduced the internal temperature of chicon to $2{\pm}1^{\circ}C$, and the precooling time of forced air cooling was 1/6 of room cooling. The half cooling time was 3 hr 21 min in room cooling and 1 hr 17 min in forced air cooling. Weight loss was less than 0.5% in all treatments both $5^{\circ}C$ and $10^{\circ}C$ MA storage and maintained higher in forced air cooling treatment. The concentration of carbon dioxide, oxygen, and ethylene of $50{\mu}m$ ceramic film packages were observed higher at $10^{\circ}C$ than $5^{\circ}C$. The precooling effect on respiration reduction was not shown at $5^{\circ}C$, but appeared that the gas concentration of precooling treatments showed less carbon dioxide and higher oxygen than non precooling treatment by 9 days after $10^{\circ}C$ storage. Ethylene concentration of precooling treatments showed lower than non precooling treatment until 3 days both $5^{\circ}C$ and $10^{\circ}C$ MA storage. Precooling showed the effect on maintaining visual quality of chicon both $5^{\circ}C$ and $10^{\circ}C$ MA storage. However, the forced air cooling that showed faster precooling rate did not appeared more precooling effect on the visual quality than room cooling because the fast air flow (6.0 m/sec) of forced air cooling hit directly on chicon outer leaves and might cause physical damage to chicon. Although the forced air cooling showed the effect on maintaining quality of chicon, but additional studies should be needed that investigated proper air flow rate and cooling box structure can prevent physical damage by air flow.

The Optimized Design of a NPC Three-Level Inverter Forced-Air Cooling System Based on Dynamic Power-loss Calculations of the Maximum Power-Loss Range

  • Xu, Shi-Zhou;He, Feng-You
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1598-1611
    • /
    • 2016
  • In some special occasions with strict size requirements, such as mine hoists, improving the design accuracy of the forced-air cooling systems of NPC three-level inverters is a key technology for improving the power density and decreasing the volume. First, a fast power-loss calculation method was brought. Its calculation principle introduced in detail, and the computation formulas were deduced. Secondly, the average and dynamic power losses of a 1MW mine hoist acting as the research target were analyzed, and a forced-air cooling system model based on a series of theoretical analyses was designed with the average power loss as a heat source. The simulation analyses proves the accuracy and effectiveness of this cooling system during the unit lifting period. Finally, according to an analysis of the periodic working condition, the maximum power-loss range of a NPC three-level inverter under multi cycle operation was obtained and its dynamic power loss was taken into the optimized cooling system model as a heat source to solve the power device damage caused by instantaneous heat accumulation. The effectiveness and feasibility of the optimization design based on the dynamic power loss calculation of the maximum power-loss range was proved by simulation and experimental results.

Comparison of the Quality of Highland-Grown Kimchi Cabbage 'Choon Gwang' during Cold Storage after Pretreatments (수확 후 전처리에 의한 고랭지 배추 '춘광' 품종의 저온 저장 중 품질 변화에 대한 비교)

  • Bae, Sang Jun;Eum, Hyang Lan;Kim, Byung-Sup;Yoon, Jungro;Hong, Sae Jin
    • Horticultural Science & Technology
    • /
    • v.33 no.2
    • /
    • pp.233-241
    • /
    • 2015
  • Kimchi cabbage 'Choon Gwang' cultivar that was grown in highlands in Gangneung was subjected to predrying, room cooling, and forced air cooling, and then packed with/without 0.02 mm HDPE film to investigate the effect of postharvest treatment on quality characteristics during 8 weeks storage at $2^{\circ}C$ (RH $90{\pm}5%$). Weight loss in forced air cooling and room cooling was lower than 3-4% with 0.02 mm HDPE film liner treatment during storage. However, it was only below 10% in room cooling without liner treatment and forced air cooling without liner treatment led to the highest weight loss, above 15%. Conversely, the control had lower weight loss than the others. SSC was $2-4^{\circ}brix$ for all treatments and there was no difference between postharvest treatments and liner treatments. Color index and firmness both showed no differences with/without 0.02 mm HDPE film and postharvest treatments. In sensory evaluation, forced air cooling with liner treatment was effective, with the highest score, especially in appearance and crispness. After 6 weeks, control kimchi cabbage without liner treatment was damaged seriously in appearance and the internal color had changed to brown. Room cooling and predrying with liner treatment changed the start of internal browning to after 8 weeks storage.