• Title/Summary/Keyword: forced circulation

Search Result 89, Processing Time 0.032 seconds

Analysis of Fuel Droplet Vaporization at High-Pressure Environment (고압상태에서의 연료액적의 증발특성 해석)

  • Lee, J.C.;Kim, Y.M.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.35-43
    • /
    • 1996
  • A vaporization model for single component fuel droplet has been developed for applying to sub- and supercritical conditions. This model can account for transient liquid heat ins and circulation effect inside the droplet, forced and natural convection, Stefan flow effect, real gas effect and ambient gas solubility into the liquid droplet in high-pressure conditions. Thermodynamic and transport properties are calculated as functions of temperature and pressure in both phases. Numerical calculations are carried out for several validation cases with the detailed experimental data. Numerical results confirm that this supercritical vaporization model is applicable to the high-pressure conditions encountered in the combustion processes of diesel engine.

  • PDF

Research of Flow Velocity and BTA According to the Streaming Electrification of Vegetable Insulating Oils (식물성 절연유의 유속과 BTA에 따른 유동대전 현상 연구)

  • Choi, Sun-Ho;Bang, Jeong-Ju;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.791-797
    • /
    • 2012
  • Mineral insulating oils are an important insulating materials in oil-filled transformer. However, the mineral oil is the cause of the environmental problem. The vegetable oils are substitutes for mineral oil because of its biodegradability characteristic. As large size and high rating of the transformer increases, the losses increase at a faster rate. So insulating oil is forced circulation in the oil-filled transformer by using oil pumps. The flow electrification occurs when insulating oil was forced to be circulated. To check the flow electrification, had conducted experiments varying factors. As a result, the streaming electrification could see the changes according to flow velocity, oil temperature and insulation materials.

CIRCULATION KINEMATICS IN NONLINEAR LABOROTORY WAVES (조파수로에서의 질량순환)

  • ;Robert T. Hudspeth
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1987.07a
    • /
    • pp.223-234
    • /
    • 1987
  • A weakly nonlinear solution is presented for the two-dimensional wave kinematics forced by a generic wavemaker of variable-draft. The solution is valid for both piston and hinged wavemakers of variable-draft that may be double articulated. The second-order propagating waves generated by a planar wave board are composed of two components; viz., a Stokes second-order wave and a second-harmonic wave forced by the wavemaker which travels at a different speed. A previously neglected time-independent solution that is required to satisfy a kinematic boundary condition on the wavemaker as well as a mixed boundary condition on the free surface is included for the first time. A component of the time-independent solution is found to accurately estimate the mean return current(correct to second-order) in a closed wave flume. This mean return current is usually estimated from kinematic considerations by a conservation of mass principle.

  • PDF

Numerical Study on Ventilation Method for Temperature Control of HRSG Building (HRSG건물 온도제어를 위한 환기방안에 관한 수치적 연구)

  • Kim, Chul Hwan;Lee, Jong Wook;Choi, Hoon Ki;Yoo, Geun Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.240-249
    • /
    • 2009
  • HRSG(Heat Recovery Steam Generator) building is large enclosed structure included various heat sources. This building needs to appropriately keep internal air temperature for worker's safety and operability of control devices. In this study, ventilation analysis is performed to find proper ventilation method for temperature control. Ventilation analysis is applied to entire internal space of the building with standard $k-{\varepsilon}$ model and enhanced wall treatment because of large size of the structure. And the ventilation method is considered natural and forced convection with two louver structures which has damper or not. Louver structure affect directly air circulation in near HRSG and lower region of the building. Forced ventilation provides strong inertial force which cause upward airflow. From the analysis, it is found that design requirement for internal air temperature can be satisfied by forced ventilation method with louver structure without damper.

Vertical arrangement of coils for efficient cargo tank heating

  • Magazinovic, Gojko
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.662-670
    • /
    • 2019
  • Tanker cargo tanks are equipped with the means of raising and maintaining the cargo discharge temperature to a suitable level. In this paper, a new heating coil design is proposed and analyzed. Contrary to conventional designs, wherein the heating coils are evenly distributed over the tank bottom, the proposed design arranges the heating coils in the central part of the tank bottom, in a vertical direction. Due to the intensive cargo circulation generated, a forced convection is superimposed on a buoyancy-driven natural convection, providing a more efficient mixed convection heat transfer mechanism. Numerical simulations performed by using a finite volume method show that in the case of 7-bar steam Bunker C heavy fuel oil heating, a five-hour circulation phase average heat transfer coefficient equals 199.2 W/m2K. This result might be taken as an impetus for the more thorough experimental examination.

Measures and Proposal for Korean Solar Water Heating System (한국형 태양열 온수급탕 시스템의 대책과 제안)

  • Kim, Sung-Soo;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.631-636
    • /
    • 2008
  • Solar thermal systems are recently refocused by higher oil prices, but did not completely restore the people's confidence owing to the past bad systems. Several types of solar water heating systems were analyzed in characteristics and some proper systems were proposed under Korean climates and system scale. As a small system, natural circulation system should be installed only in a southern region of Korea, with a freeze protection valve instead of heating coil for freeze protection. In most area of Korea, the forced circulation type with a heat exchange coil inside a thermal storage tank or with a spiral-jacketed storage tank, proposed and verified by the authors, has a merit of stable performance and freeze protection.

Pressure Drop Characteristics on HTS Power Cables with LN2 Flow (초전도 케이블 냉각유로에서의 압력강하 특성)

  • Koh Deuk-Yong;Yeom Han-Kil;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • High temperature superconducting (HTS) power cable requires forced sub-cooled LN2 flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65 K and 77 K. The HTS power cable needs sufficient cooling to overcome its low temperature heat load. For successful cooling, the hydraulic characteristics of the HTS power cable must be well investigated to design the cables. Especially, the pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. This paper describes measurement and investigation of the pressure drop of the cooling system. In order to reduce the total pressure drop of the cooling system, the flow rate of liquid nitrogen must be controlled by rotational speed of the circulation pump.

Seasonal Variation of Global Volume Transport Calculated from an Ocean General Circulation Model

  • Jang, Chan-Joo;Noh, Yign;Kim, Cheol-Ho
    • Ocean and Polar Research
    • /
    • v.24 no.1
    • /
    • pp.1-18
    • /
    • 2002
  • Seasonal variation in global transport calculated from an ocean general circulation model (OGCM) has been assessed through the comparison with observational estimates. The OGCM based on the GFDL MOM1.1 has honzontal grid interval of 10 and 21 verticle levels, and was integrated for 31 years forced by climatological wind stress, freshwater flux, and heat flux with restoring. General features of the world ocean circulation are well reproduced, which include the western boundary currents such as the Kuroshio and the Agulhas Current, the Equatorial Current system, the Antarctic Circumpolar Current, and the Weddell Sea gyres. Also well resolved is the remarkable seasonal variation in the depth-integrated flows in the northern Indian Ocean due to the monsoonal wind. Monthly variation is found to be dominant in the transport of the Antarctic Circumpolar Current through the Drake Passage in accordance with observational estimates. It has been shown that the mid-latitude depth-integrated flows obey the Sverdrup relation, except for some regions such as continental shelf regions where the interaction between stratification and bottom topography is critical.

A Numerical Modeling Study on the Seasonal Variability in the Gulf of Alaska (알라스카 만의 계절변화에 대한 수치모형 실험)

  • Bang, In-Kweon;Zygmunt Kowlik
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.3
    • /
    • pp.309-325
    • /
    • 1994
  • Ocean circulation in the Gulf of Alaska is remarkably constant throughout the year despite of being forced by one of the largest seasonal wind stresses in the world. To explain the small seasonal changes in the transport of Alaska Stream. a set of numerical models is employed. First a diagnostic approach is applied to reproduce circulation from the observed density structure. The results reveals the very small seasonal changes in the Alaska Stream transport. Next a series of the prognostic models is used: a barotropic model. a flat bottom baroclinic model, and baroclinic model with topography. These models reveal the influence of topography and baroclinicity on the ocean's response to the seasonal wind forcing. The intercomparisons of the various model results suggest that the seasonal response of the baroclinic ocean is primary barotropic and the resultant barotropic circulation is weakened by the scattering effect of the bottom topography.

  • PDF

NUMERICAL MODEL FOR STORM SURGES

  • Yamashita, Takao;Bekku, Isao
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.1-4
    • /
    • 1995
  • Storm surges are defined as abnormal changes of sea surface elevation whose periods range from several hours to days. The generation mechanism is separated into two. One is sea water suction due to atmospheric depression and the other is wind-driven sea water circulation. The former is a forced long-wave motion which is accompanied by a typhoon. (omitted)

  • PDF