• Title/Summary/Keyword: force sensor

Search Result 1,226, Processing Time 0.027 seconds

Performance Improvement of a 6-Axis Force-torque Sensor via Novel Electronics and Cross-shaped Double-hole Structure

  • Kang Chul-Goo
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.3
    • /
    • pp.469-476
    • /
    • 2005
  • Performance of a force-torque sensor is affected significantly by an error signal that is included in the sensor signal. The error sources may be classified mainly into two categories: one is a structural error due to inaccuracy of sensor body, and the other is a noise signal existing in sensed information. This paper presents a principle of 6-axis force-torque sensor briefly, a double-hole structure to be able to improve a structural error, and then a signal conditioning to reduce the effect of a noise signal. The validity of the proposed method is investigated through experimental study, which shows that SIN ratio is improved significantly in our experimental setup, and the sensor can be implemented cheaply with reasonable performance.

Development of 6-Axis Force/Moment Sensor Considered Adult Weight for a Humanoid Robot's Foot (성인 체중을 고려한 로봇의 지능형 발을 위한 6축 힘/모멘트센서 개발)

  • Kim, Gab-Soon;Yoon, Jung-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.7 s.196
    • /
    • pp.90-97
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor considered adult weight far an intelligent foot of humanoid robot. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself and control the foot using the forces and moments. The applied forces and moments should be measured from a 6-axis force/moment sensor attached to the foot, which is composed of Fx sensor, Fy sensor, Fz sensor, Mx sensor, My sensor and Mz sensor in a body. Each sensor should get the deferent rated load, because the applied forces and moments to foot in walking are deferent. Therefore, one of the important things in the sensor is to design each sensor with the deferent rated load and the same rated output. In this paper, a 6-axis force/moment sensor (rated load of Fx and Fy are 500Nm and Fz sensor is 1000N, and those of Mx and My are 18Nm, Mz sensor is 8Nm) for perceiving forces and moments in a humanoid robot's foot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing elements (plate-beams) of the sensor were designed using by ANSYS software (FEM (Finite Element Method) program). Then, a 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with that from the characteristic test.

Development of Uniaxial Force Sensor Array for Tactile Sensation Using Fiber Bragg Gratings (광섬유 브래그 격자를 이용한 촉감감지용 단축 힘 센서 어레이 개발)

  • Heo, Jin-Seok;Lee, Jung-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1160-1165
    • /
    • 2006
  • In this paper, the 2-dimensional uniaxial force sensors array is introduced to detect the distributed force using fiber Bragg gratings. Uniaxial force transducer was designed to avoid the chirping and micro bending which degrade the performance of the sensor. The Brags wavelength shift of the sensor was estimated using the finite element analysis. Using this uniaxial force sensor, the uniaxial force sensors array $(3{\times}3)$ was fabricated, and the Performance of this sensors array was evaluated. The Presented sensors may has very simple configuration and its wiring is very simple compared with any other force sensors arrays.

The Effect of the Deformation on the Sensitivity of a Flexible PDMS Membrane Sensor to Measure the Impact Force of a Water Droplet (액적의 충격력 측정을 위한 유연 멤브레인 센서의 PDMS 변형에 의한 민감도의 영향)

  • Kang, Dong Kwan;Lee, Sangmin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.5
    • /
    • pp.16-21
    • /
    • 2022
  • This study investigates the effect of the deformation on the sensitivity of a flexible polydimethylsiloxane (PDMS) membrane sensor. A PDMS membrane sensor was developed to measure the impact force of a water droplet using a silver nanowire (AgNW). The initial deformation of the membrane was confirmed with the application of a tensile force (i.e., tension) and fixing force (i.e., compressive force) at the gripers, which affects the sensitivity. The experimental results show that as the tension applied to the membrane increased, the sensitivity of the sensor decreased. The initial electrical resistance increased as the fixing force increased, while the sensitivity of the sensor decreased as the initial resistance increased. The movement of the membrane due to the impact force of the water droplet was observed with a high-speed camera, and was correlated with the measured sensor signal. The analysis of the motion of the membrane and droplets after collision confirmed the periodic movement of not only the membrane but also the change in the height of the droplet.

Development of 6-axis Ankle Force/Moment Sensor for an Intelligent Foot of a Humanoid Robot (인간형 로봇의 지능형 발을 위한 6축 발목 힘/모멘트센서)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.27-36
    • /
    • 2007
  • This paper describes the development of 6-axis ankle force/moment sensor for the intelligent feet of a humanoid robot. When the robot walks on uneven terrain, the feet should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz from the attached 6-axis force/moment sensor on their ankles. Papers have already been published have some disadvantages in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis ankle force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to get the similar rated output under each rated load. Also, the size of the sensor is very important for mounting to robot's feet. Therefore, the diameter should be below 100 mm and the height should be below 40mm. In this paper, first, the structure of a 6-axis ankle force/moment sensor was modeled for a humanoid robot's feet newly, Second, the equations to predict the strains on the sensing elements was derived, third, the size of the sensing elements was designed by using the equations, then, the sensor was fabricated by attaching straingages on the sensing elements, finally, the characteristic test of the developed sensor was carried out. The rated outputs from the derived equations agree well with the results from the experiments. The interference error of the sensor is less than 2.94%.

Development of Two-Finger Force Measuring System to Measure Two-Finger Gripping Force and Its Characteristic Evaluation (단축 힘센서를 이용한 두 손가락 잡기 힘측정장치 개발 및 특성평가)

  • Kim, Hyeon-Min;Shin, Hi-Suk;Yoon, Joung-Won;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.172-177
    • /
    • 2011
  • Finger patients can't use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers(thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). At present, most hospitals have used a thin plastic-plate for measuring the two-finger grasping force, and we can only judge that they can grasp the plate with their two-finger through it, because the plate can't measure the two-finger grasping force. But, recently, the force measuring system for measuring two-finger grasping force was developed using three-axis force sensor, but it is very expensive, because it has a three-axis force sensor. In this paper, two-finger force measuring system with a one-axis force sensor which can measure two-finger grasping force was developed. The one-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP(Digital Signal Processing). Also, the grasping force test of men was performed using the developed two-finger force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods, and the system can be used for measuring two-finger grasping force.

Design of 3-component Force/Moment Sensor with Force/Moment Ratio of Wide Range (넓은 범위의 힘/모멘트비를 갖는 3분력 힘/모멘트 센서 설계)

  • Kim, Gap-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.214-221
    • /
    • 2001
  • This paper describes the design of 3-component force/moment sensor with the force and moment ratio of wide range. It can measure the x-direction force Fx, y-direction force Fy and z-direction moment Mz simultaneously. In order to accurately measure forces and moment using 3-component force/moment sensor, it should get suitable force and moment ratio(the ratio of force Fx=200 N and moment Mz=20 Nm is ten to one), and small interference error. In this paper, in order to design the 3-component force/moment sensor with the force and moment ratio of wide range, the procedures are performed as follow : 1) the derivation of the equations to predict the bending strains on the surfaces of the plate-beams under the force or the moments, 2) the determination of the size of the sensing elements of the force/moment sensor by using the derived equations, 3) the Finite Element Method(FEM) analysis and the characteristic test for confirming the strains from the theory analysis, 4) the selection of the attachment locations of the strain gages of each sensor, 5) the analysis of the rated strain and the interference error at the attachment location of strain gages. It reveals that the rated strains calculated from the derived equations make a good agreement with the results from the Finite Element Method analysis and the characteristic test.

  • PDF

Design of a Three-Axis Force Sensor for Wrist Bending-Exercise Rehabilitation Robot (손목굽힘운동 재활로봇을 위한 3축 힘센서 설계)

  • Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.118-123
    • /
    • 2013
  • Most serious stroke patients have the paralysis of their wrists, and can't use of their hands freely. But their wrists can be recovered by rehabilitation exercise. Recently, professional rehabilitation therapeutists exercise the wrists of stroke patients in hospital. But the wrists of stroke patients have not rehabilitated, because the therapeutists are much less than stroke patients in number. Therefore, the wrist bending-exercise rehabilitation robot that can measure the bending force of the patients' wrists is developed. In this paper, the three-axis force sensor was designed for the wrist bending-exercise rehabilitation robot. As a test results, the interference error of the three-axis force sensor was less than 0.85%. It is thought that the sensor can be used to measure the wrist bending force of the patient.

Development and Application of Polymer-based Flexible Force Sensor Array (폴리머 재료를 이용한 유연 수직/수평 힘 센서 어레이 개발 및 응용)

  • Hwang, Eun-Soo;Yoon, Young-Ro;Yoon, Hyoung-Ro;Shin, Tae-Min;Kim, Yong-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.142-149
    • /
    • 2009
  • This paper proposes and demonstrates novel flexible contact force sensing devices for 3-dimensional force measurement. To realize the sensor, polyimide and polydimethylsiloxane are used as a substrate, which makes it flexible. Thin-film metal strain gauges, which are incorporated into the polymer, are used for measuring the three-dimensional contact forces. The force sensor characteristics are evaluated against normal and shear load. The fabricated force sensor can measure normal loads up to 4N. The sensor output signals are saturated against load over 4N. Shear loads can be detected by different voltage drops in strain gauges. The device has no fragile structures; therefore, it can be used as a ground reaction force sensor for balance control in humanoid robots. Four force sensors are assembled and placed in the four corners of the robot's sole. By increasing bump dimensions, the force sensor can measure load up to 20N. When loads are exerted on the sole, the ground reaction force can be measured by these four sensors. The measured forces can be used in the balance control of biped locomotion system.

Design of Force Measuring System for Deburring Using Industrial Robot (산업용로봇을 이용한 디버링을 위한 힘측정시스템 설계)

  • Lee, Gyeong Jun;Kim, Han Sol;Kim, Chong Jin;Kim, Hyeon Min;Kim, Gab Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.653-660
    • /
    • 2015
  • This paper describes the design of the force measuring system for an industrial robot's deburring work. The force measuring system is composed of a three-axis force sensor, a measuring device, a housing and a cover. The three-axis force sensor can detect x-direction force, y-direction force and z-direction force at the same time. The measuring device is designed using DSP(Digital Signal Processor), and have a RS-232 and a RS-485 communication port for sending force data to PC or other controller. As a result of test, the repeatability error and the non-lineality error of the three-axis force sensor are less than 0.03%, and the interference error of the sensor is less than 0.95%. It is thought that the force measuring system can be used for an industrial robot's deburring work.