• Title/Summary/Keyword: force/torque

Search Result 1,046, Processing Time 0.023 seconds

Design and Analysis of Hybrid Stator Bearingless SRM

  • Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.94-103
    • /
    • 2011
  • This paper presents a novel bearingless switched reluctance motor (BLSRM) with decoupled torque and suspending stator poles. BLSRM is different from conventional bearingless switched reluctance motors (SRMs) because its suspending poles are separated from the torque poles. Perpendicularly placed suspending poles are designed to produce a continuous radial force to suspend the rotor. Due to the independent suspending and torque poles, BLSRM produces a suspending force with excellent linearity according to the rotor position and independent characteristics of the torque current. The air-gap is easier to control than in conventional SRMs with their linear and independent characteristics. Furthermore, to verify the proposed structure, a mathematical model for the suspending force is derived. Finite element analysis is also employed to compare BLSRM and conventional SRMs expressions of suspending force. A prototype motoris designed and manufactured to verify the effectiveness of the proposed bearingless structure.

Rotor Pole Design and Characteristics Analysis of the Bearingless Switched Reluctance Motor Considering Fringing Flux (프린징 자속을 고려한 베어링리스 SRM 회전자극 설계 및 특성분석)

  • Lee, Chan-Kyo;Oh, Ju-Hwan;Shin, Kwang-Chul;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • In this paper, a novel Bearingless Switched Reluctance Motor(BLSRM) with the shoe rotor pole in order to minimize the torque ripple and the suspension force ripple at an overlap position is proposed. For reduction the torque ripple and the suspension force ripple at an overlap position, the fringing flux is used for the main flux. This configuration of the rotor pole results in more average torque with high suspension force. In addition, this paper is compared the transient characteristics using the inductance look-up table. The torque, radial force and flux density are analyzed by finite element method.

Development of Experimental Equation of Hood Frame for Vehicle Considering Operating Angle (작동각을 고려한 차량 후드 프레임의 실험식 개발)

  • Song, Yo-Sun;Hur, Kwan-Do;Son, In-Soo
    • Journal of Power System Engineering
    • /
    • v.20 no.3
    • /
    • pp.57-63
    • /
    • 2016
  • This paper presents the experimental result and theoretical analysis result to investigate the correlation between the operating force, angle and locking torque for vehicle hood frame. Also, we derived the experimental equation that using the results for experiment and theory. The hood frame is switching-devices used for opening and closing the vehicle hood. It needs the correlation data between locking torques of each joint, operating force and angle of hood frame. The correlation data for torque and reaction force of hood frame obtained through experiment and theory analysis. Finally, the experimental equation of the locking torque prediction for the hood frame is derived.

Estimation of Friction-torque to Improve Accuracy of Estimated Contact-force for a Walking Robot (접촉력 추정 정확도 향상을 위한 보행로봇의 마찰 토크 추정)

  • Lee, Jonghwa;Kang, Hangoo;Lee, Jihong;Jun, Bong-Huan
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.398-403
    • /
    • 2015
  • This paper introduces a method to estimate the contact-force of the leg of a walking robot and proposes a solution to a shortcoming of the previous study. This shortcoming was the deteriorating performance when estimating the contact-force whenever the rotation of each joint was reversed. It occurred because the friction-torque of each joint was not considered. In order to solve this problem, a friction-torque model for a robot leg was developed based on repetitive experimentation and used to improve the contact-force estimation performance. We verified the performance of the proposed method experimentally.

Design and Analysis of Double Stator Type Bearingless Switched Reluctance Motor (이중고정자구조를 가지는 베어링리스 스위치드 릴럭턴스 전동기의 설계와 해석)

  • Peng, Wei;Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.746-752
    • /
    • 2011
  • In this paper, a novel bearingless switched reluctance motor (BLSRM) with double stator is proposed. This motor has two stators. Torque stator is outside, which mainly produces rotational torque. Radial force stator is inside, which mainly generates radial force to suspend the rotor. A novel structure and operating principle are presented. And characteristics of the proposed structure such as magnetic flux distribution, inductance, torque and radial force are analyzed through finite element method. From the analysis, the proposed BLSRM has linear characteristic of radial force and independence from torque current.

A Comparison of Ground Reaction Force of High School Swimmers in Accordance with Starting Motions (수영 출발동작의 지면반력 차이 비교 II)

  • Kim, Kew-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.69-80
    • /
    • 2007
  • The purpose of this study was to investigate the difference of ground reaction forces of swimming athletes during their starting motion and to find out the most effective starting motions which were used in swimming athletes. The subjects were 9 male and 8 female high school swimming athletes who were athletic career over 7 years and used three starting motions in competition. The ground reaction forces were measured from each athletes performing three starting motion each of the open grap starting motion, closed grap starting motion and track starting motion. For the measurement, the force platform of AMTI company was utilized, and the analysis on measured ground reaction forces were used of Biosoft(Ver. 1.0). The items measured were stance time, Fz max deceleration force and Fz max deceleration force time, Fz mid stance force and Fz mid stance force time, Fz max acceleration force and Fz max acceleration force time, Torque maximum and Torque maximum time, Torque average, Excursion along Y axis of center of pressure of foot, Excursion along X axis of center of pressure of foot, Length of center of pressure of foot, Average velocity of center of pressure of foot. The data measured by the closed grap starting motion, open grap starting motion and track starting motion were analyzed by one-way repeated ANOVA. The results were as follows ; 1. The Fz max deceleration force time, Fz mid stance force, Fz max acceleration force, Torque maximum and Torque maximum time, Excursion along Y axis of center of pressure of foot, Average velocity of center of pressure of foot were significantly fast and large in the closed grap starting motion then open grap starting motion and track starting motion. 2. The Excursion along Y axis of center of pressure of foot was significantly long in the closed grap starting motion then open grap starting motion and track starting motion.

Effect of Fatigue on Force-Matching in the Quadriceps Muscle

  • Song, Young-Hee;Lee, Su-Young;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.10-15
    • /
    • 2006
  • This study examined the ability of human subjects to match a force in their quadriceps muscle during fatigue. Twenty subjects (mean age: 23.4 yrs, mean height: 167.8 cm, mean weight, 62.6 kg) were enrolled in the experiment. In the force-matching task, the quadriceps muscle generated 50% of the MVIC (maximum voluntary isometric contraction) torque under visual control and then without visual feedback. After inducing fatigue in the quadriceps muscle, the subjects were required to match 50% of the MVIC torque without visual feedback. The perceived magnitude of the force and force-matching errors were measured. 50% of the MVIC torque was perceived from 39.96 Nm in the pre-fatigue condition to 44.95 Nm in the post-fatigue condition. 50% of the MVIC torque-matching errors increased significantly from .55% in the pre-fatigue condition to 9.6% in the post-fatigue condition (p<.001). in addition, there were significantly more force-matching errors in women than in men (p<.01). In conclusion muscle fatigue can interfere with a subject's ability to match a force. This suggests that muscle fatigue may contributes to the sensitization of the proprioception.

  • PDF

Speed Sensorless Torque Monitoring During Machining on CNC Lathe (CNC 선반가공 중 속도 센서리스 토크 감시)

  • Hong, Ik-Jun;Kwon, Won-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.222-229
    • /
    • 2004
  • In this paper, the torque of CNC spindle motor during machining is estimated without speed measuring sensor. The CNC spindle system is divided into two parts, the induction spindle motor part and mechanical part. In mechanical part, the variation of the frictional force due to the increment of the cutting torque and the effect of damping coefficient is investigated. Damping coefficient is found to be a function of spindle speed and not influenced by the weight of the load, while frictional force is a function of both the cutting torque and spindle speed. Experimental equations are drawn for damping coefficient and Coulomb friction as a function of spindle speed. Incremental frictional torque Is also obtained as a function of both cutting torque and spindle speed. Graphical programming is used to implement the suggested algorithm to monitor the torque of an induction motor in real time. Torque of the spindle induction motor is estimated well in about average 3% error range under various cutting conditions.

A Study on the Transmitted Torque of Self Clamping Friction Clutch (자기 체결 마찰 클러치의 전달 토크에 관한 연구)

  • Wang, Jee-Seok;Kim, Jong-Do;Yoon, Hee-Jong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1149-1156
    • /
    • 2008
  • The principle of self clamping friction clutch is presented in this paper and the transmitted torque capacity is also calculated. In order to enlarge the friction force, a part of rotating force of driving side is converted to normal force of friction materials by clamping arm. The increased normal force of friction materials assures the large friction force and the transmitted torque capacity of clutch becomes large. The self clamping friction clutch is adopted in the tube type air pressure clutch and the condition of stability is investigated. It is proven that the inclined angle of clamping arm and the friction factor of friction materials are the essential elements in stability and torque capacity of self clamping friction clutch. The transmitted torque capacity of self clamping friction clutch is compared with air pressure clutch. The normal force of friction lining is magnified by 1/(1-k) and the transmitted torque capacity is also magnified with same proportion comparing with air pressure clutch. The larger the friction factor of friction lining, the larger the magnification factor. The longer the clamping arm, the smaller the magnification factor. It must be also noted that the value of k=${\mu}Y/X$ is the criterion of stability. If the value of k=${\mu}Y/X$ is greater than or equal to 1, the self clamping friction clutch is unstable and it can not be used as clutch.