• Title/Summary/Keyword: food risk

Search Result 2,568, Processing Time 0.05 seconds

Association Between Parental Socioeconomic Level, Overweight, and Eating Habits with Diet Quality in Korean Sixth Grade School Children (부모의 사회경제적 수준 (가구 월수입, 부모 교육수준)과 초등학교 6학년 학생의 과체중 및 식습관, 식사 질과의 관계)

  • Jang, Han-Byul;Park, Ju-Yeon;Lee, Hye-Ja;Kang, Jae-Heon;Park, Kyung-Hee;Song, Ji-Hyun
    • Journal of Nutrition and Health
    • /
    • v.44 no.5
    • /
    • pp.416-427
    • /
    • 2011
  • This study investigated the association among parental socioeconomic level, overweight, and eating habits with diet quality in Korean sixth grade school children. A 3-day dietary survey was conducted, and a questionnaire and anthropometric data were collected from the Korean child obesity cohort (320 boys and 345 girls). The children were classified into two groups (low or high level) based on monthly household income and paternal and maternal education status. Lower maternal education status was associated with a higher risk for overweight in girls (odd ratio, 1.91; 95% confidence interval 1.07-3.44), whereas belonging to a higher socioeconomic group in terms of parental income or parental education level resulted in the consumption of significantly more fruit. Boys did not show significant differences in the intake of most nutrients or diet quality regardless of socioeconomic status. However, girls in the lower socioeconomic group had a lower food habit score (higher frequency of breakfast skipping and ramen noodle consumption), diet quality, and intake of nutrients (carbohydrate, vitamin C, potassium, and fiber) than those in the higher socioeconomic group. Therefore future nutrition policies and interventions should support parents and children with lower socioeconomic status to develop health-related behaviors that may prevent childhood overweight.

A Pilot Study for the Remote Monitoring of IMRT Using a Head and Neck Phantom (원격 품질 보증 시스템을 사용한 세기변조 방사선치료의 예비 모니터링 결과)

  • Han, Young-Yih;Shin, Eun-Hyuk;Lim, Chun-Il;Kang, Se-Kwon;Park, Sung-Ho;Lah, Jeong-Eun;Suh, Tae-Suk;Yoon, Myong-Geun;Lee, Se-Byeong;Ju, Sang-Gyu;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.249-260
    • /
    • 2007
  • Purpose: In order to enhance the quality of IMRT as employed in Korea, we developed a remote monitoring system. The feasibility of the system was evaluated by conducting a pilot study. Materials and Methods: The remote monitoring system consisted of a head and neck phantom and a user manual. The phantom contains a target and three OARs (organs at risk) that can be detected on CT images. TLD capsules were inserted at the center of the target and at the OARs. Two film slits for GafchromicEBT film were located on the axial and saggital planes. The user manual contained an IMRT planning guide and instructions for IMRT planning and the delivery process. After the manual and phantom were sent to four institutions, IMRT was planed and delivered. Predicted doses were compared with measured doses. Dose distribution along the two straight lines that intersected at the center of the axial film was measured and compared with the profiles predicted by the plan. Results: The measurements at the target agreed with the predicted dose within a 3% deviation. Doses at the OARs that represented the thyroid glands showed larger deviations (minimum 3.3% and maximum 19.8%). The deviation at OARs that represented the spiral cord was $0.7{\sim}1.4%$. The percentage of dose distributions that showed more than a 5% of deviation on the lines was $7{\sim}27%$ and $7{\sim}14%$ along the horizontal and vertical lines, respectively. Conculsion: Remote monitoring of IMRT using the developed system was feasible. With remote monitoring, the deviation at the target is expected to be small while the deviation at the OARs can be very large. Therefore, a method that is able to investigate the cause of a large deviation needs to be developed. In addition, a more clinically relevant measure for the two-dimensional dose comparison and pass/fail criteria need to be further developed.

Prospective for Successful IT in Agriculture (일본 농업분야 정보기술활용 성공사례와 전망)

  • Seishi Ninomiya;Byong-Lyol Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.2
    • /
    • pp.107-117
    • /
    • 2004
  • If doubtlessly contributes much to agriculture and rural development. The roles can be summarized as; 1. to activate rural areas and to provide more comfortable and safe rural life with equivalent services to those in urban areas, facilitating distance education, tole-medicine, remote public services, remote entertainment etc. 2. To initiate new agricultural and rural business such as e-commerce, real estate business for satellite officies, rural tourism and virtual corporation of small-scale farms. 3. To support policy-making and evaluation on optimal farm production, disaster management, effective agro-environmental resource management etc., providing tools such as GIS. 4. To improve farm management and farming technologies by efficient farm management, risk management, effective information or knowledge transfer etc., realizing competitive and sustainable farming with safe products. 5. To provide systems and tools to secure food traceability and reliability that has been an emerging issue concerning farm products since serious contamination such as BSE and chicken flu was detected. 6. To take an important and key role for industrialization of farming or lam business enterprise, combining the above roles.

Plasma Levels of High Molecular Weight Adiponectin are Associated with Cardiometabolic Risks in Patients with Hypertension (고혈압 환자에서 혈장 고분자량 아디포넥틴 농도와 심장-대사위험인자와의 관련성 연구)

  • Chung, Hye-Kyung;Shin, Min-Jeong
    • Journal of Nutrition and Health
    • /
    • v.41 no.8
    • /
    • pp.733-741
    • /
    • 2008
  • In the present study, we comprehensively examined the associations of plasma levels of total adiponectin and high molecular weight (HMW) adiponectin with the features of cardiometabolic risks including body fat distribution, dyslipidemia, insulin resistance and inflammatory markers in a cross-sectional study of 110 treated hypertensive patients. Blood lipid profiles, high sensitivity C-reactive protein (hsCRP) and homeostasis model assessment of insulin resistance (HOMA- IR) derived from fasting glucose and insulin concentrations were determined. Plasma levels of tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$), interleukin-6 (IL-6) and intercellular adhesion molecule-1 (ICAM-1) were analyzed using ELISA. The results showed that plasma levels of HMW-adiponectin were negatively associated with body mass index (BMI, r = - 0.203, p < 0.05) and waist circumference (r = -0.307, p < 0.01), which was not shown in total adiponectin. Plasma levels of HMW-adiponectin were negatively associated with triglyceride (r = -0.223, p < 0.05) and positively associated with HDL-cholesterol (r = 0.228, p < 0.05). Plasma levels of adiponectin were positively associated with HDL-cholesterol (r = 0.224, p < 0.05). Plasma levels of HMW-adiponectin were negatively associated with hsCRP (r = -0.276, p < 0.01) and IL-6 (r = -0.272, p < 0.01). In addition, there were weak associations between plasma levels of HMWadiponectin and TNF-${\alpha}$ (r = -0.163, p = 0.07) and ICAM-1 (r = -0.158, p = 0.09). However, there were no significant associations of total adiponectin with inflammatory markers except hsCRP (r = -0.203, p < 0.05). Stepwise multiple linear regression analysis showed that only plasma levels of HMW-adiponectin was an independent factor influencing serum levels of hsCRP, a marker of systemic low grade inflammation, after adjusting for age, gender, BMI, waist circumference, alcohol intake, smoking status, blood lipids, total adiponectin and drug use (p < 0.01). These results suggest that HMW-adiponectin, rather than total adiponectin, is likely to be closely associated with the features of cardiometabolic risks in treated hypertensive patients and might be effective biomarker for the prediction of cardiovascular disease.

Estimation of Fresh Weight, Dry Weight, and Leaf Area Index of Soybean Plant using Multispectral Camera Mounted on Rotor-wing UAV (회전익 무인기에 탑재된 다중분광 센서를 이용한 콩의 생체중, 건물중, 엽면적 지수 추정)

  • Jang, Si-Hyeong;Ryu, Chan-Seok;Kang, Ye-Seong;Jun, Sae-Rom;Park, Jun-Woo;Song, Hye-Young;Kang, Kyeong-Suk;Kang, Dong-Woo;Zou, Kunyan;Jun, Tae-Hwan
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.4
    • /
    • pp.327-336
    • /
    • 2019
  • Soybean is one of the most important crops of which the grains contain high protein content and has been consumed in various forms of food. Soybean plants are generally cultivated on the field and their yield and quality are strongly affected by climate change. Recently, the abnormal climate conditions, including heat wave and heavy rainfall, frequently occurs which would increase the risk of the farm management. The real-time assessment techniques for quality and growth of soybean would reduce the losses of the crop in terms of quantity and quality. The objective of this work was to develop a simple model to estimate the growth of soybean plant using a multispectral sensor mounted on a rotor-wing unmanned aerial vehicle(UAV). The soybean growth model was developed by using simple linear regression analysis with three phenotypic data (fresh weight, dry weight, leaf area index) and two types of vegetation indices (VIs). It was found that the accuracy and precision of LAI model using GNDVI (R2= 0.789, RMSE=0.73 ㎡/㎡, RE=34.91%) was greater than those of the model using NDVI (R2= 0.587, RMSE=1.01 ㎡/㎡, RE=48.98%). The accuracy and precision based on the simple ratio indices were better than those based on the normalized vegetation indices, such as RRVI (R2= 0.760, RMSE=0.78 ㎡/㎡, RE=37.26%) and GRVI (R2= 0.828, RMSE=0.66 ㎡/㎡, RE=31.59%). The outcome of this study could aid the production of soybeans with high and uniform quality when a variable rate fertilization system is introduced to cope with the adverse climate conditions.

Clinical Evaluation of Implant-Supported Fixed Prostheses (임플란트-지지 고정성 보철물의 임상적 상태에 대한 평가)

  • Park, Chan-Yong;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.317-326
    • /
    • 2013
  • This study was to compare the cumulative survival rate of implant-supported fixed prostheses and to analyze association between risk factors and cumulative survival rate of implant-supported fixed prostheses. In order to assess the clinical status of implant-supported fixed prostheses, individuals who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between 2000 to 2007 were examined. The results of this study were as follows: 1. Length of service of implant-supported fixed prostheses was $6.6{\pm}32.0$ years (mean), 11.7 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 3. Reason of tooth extraction wax found to have statistically significant influence on implant-supported fixed prostheses (P<.05). The longevity of fixed prostheses was low in tooth extraction case due to periodontal disease (median:9.0 years). 4. Location of implant-supported fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in molar region (median:8.8 years). 5. Number of units in implant-supported fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of implant-supported fixed prostheses (P>.05). 7. Food impaction (40.5%), porcelain fracture (25.8%), screw loosening (23.6%) were frequent complications.

An Epidemiologic Investigation of Enteropathogenic Escherichia Coli (EPEC) Outbreak in Seongju-gun, Gyeongbuk, 2004 (2004년 경상북도 성주군에서 발생한 장병원성대장균의 유행에 관한 역학조사)

  • Baik, Dalh-Yeon;Yeom, Seok-Hyeon;Lee, Kwan;Lim, Hyun-Sul
    • Journal of agricultural medicine and community health
    • /
    • v.30 no.1
    • /
    • pp.39-50
    • /
    • 2005
  • Objectives: This investigation was carried out to explore the source and the mode of transmission of the diarrhea outbreak in Seongju-gun, Gyeongbuk, 2004 Methods: The authors conducted a questionnaire survey among the 275 persons (students, staff members and cooks) who ingested the possibly contaminated foods. We also investigated the drinking water and the dining facility, and we reviewed the process of cooking the salad, which was the presumed cause of the Enteropathogenic Escherichia coli(EPEC) diarrhea. The confirmed EPEC diarrheal case was defined as culture positive for EPEC, and the suspicious case was defined as diarrheal case with symptoms more than one of fever, vomiting and tenesmus. Results: The attack rate of EPEC diarrhea was 36.7%, and there were 8 confirmed cases. The possibility of the drinking being a source of the infection was very low, for chlorine was detected in all the drinking water via reviewing the past records and using a portable detector. The foods that were significantly associated with diarrhea were found. The relative risk (RR) for the lunch served Jul 7 was 4.12 (95% CI: 1.39-12.20). Among the non-boiled foods that were finally served, the RR for the salad was 1.66 (95% CI: 1.07-2.57). The cause of this outbreak was presumed to be the contaminated foods that were prepared by cooks using rubber glove with holes, and especially the salad and foods that were served sans boiling on Jul 7. Conclusions: Though this EPEC infection was not so clinically important, if a larger outbreak occurred, it might severely affect the public health. It is recommended to develop the more safe methods for cooking foods, and to strengthen the sanitary processing foods.

  • PDF

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Bacteriological and Physiochemical Quality of Seawater and Surface Sediments in Sacheon Bay (사천만의 해수 및 표층 퇴적물의 세균학적 및 이화학적 특성)

  • Park, Jun-Yong;Kim, Yeong-In;Bae, Ki-Sung;Oh, Kwang-Soo;Choi, Jong-Duck
    • Journal of agriculture & life science
    • /
    • v.44 no.2
    • /
    • pp.7-15
    • /
    • 2010
  • This study was conducted to investigate the bacteriological and physiological quality of seawater and surface sediments in Sacheon Bay of Korea from January to September in 2009. During the study period, the means of temperature was range from 5.3 to $24.9^{\circ}C$ (mean $17.7{\pm}0.4^{\circ}C$), transparency range from 1.4 to 2.5 m (mean $1.8{\pm}0.5m$), suspended solid ranged from 16.2 to 35.8 mg/L (mean $24.2{\pm}2.2mg/L$), chemical oxygen demand ranged from 1.42 to $3.29mgO_2/L$ (mean $2.06{\pm}0.55mgO_2/L$), dissolved oxygen ranged from 6.7 to 9.5mg/L (mean $7.9{\pm}0.6mg/L$), respectively. Seafood, if eaten raw, carries the risk of food poisoning. Seafood poisoning is often cause by pathogenic microorganism originating from fecal contamination, such as Salmonella sp., Shigella sp. and norovirus. Fecal coliforms are an important indicator of fecal contamination. Therefor, data on fecal coliform are very important for evaluating the safety of fisheries in coastal areas. So, we investigated the sanitary indicate bacteria. In this study, 56 sea water samples were collected from the Sacheon Bay, and total and fecal coliforms were compared and analyzed. The coliform group and fecal coliform MPN's of sea water in Sacehon Bay were ranged from <1.8~7,900 MPN/100mL (GM 214.7 MPN/100mL) and <1.8~330 MPN/100mL (GM 9.7 MPN/ 100mL), respectively. Total coliforms were detected in 75.0% of the samples and 76.2% of the total coliforms were fecal coliforms. During the study period, the means of water content, ignition loss, COD, and acid volatile sulfates in sediments in Sacheon Bay were $53.28{\pm}2.58%$, $9.38{\pm}0.42%$, $14.23{\pm}3.36mgO_2/g$, $0.09{\pm}0.07mgS/g$, respectively.