• Title/Summary/Keyword: focus lens

Search Result 226, Processing Time 0.028 seconds

Design of a 10× Zoom Lens with an Expander for an MWIR Camera Using Athermal Material Composition Method (비열화 소재 구성 방법을 이용한 중적외선 카메라용 확장형 10배 줌 렌즈 설계)

  • Ryu, Tae-Sik;Park, Sung-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.287-294
    • /
    • 2022
  • This study presents a method for designing an athermal middle wavelength infrared (MWIR) zoom lens with the iterative selection of material compositions on an athermal glass map. The optical properties of glass for MWIR are generally very sensitive to temperature, compared with visible glass. To compensate for focus error due to temperature change, the non-athermalized zoom system requires a large amount of movement of a compensator, which results in an unstable zoom system. To solve this problem, the material compositions for an athermal zoom lens have effectively been obtained using the thermal aberration correction process analytically on an athermal glass map. An expander lens is used to enlarge the focal lengths of an original main zoom lens two times. Finally, while this expander is attached to an original athermal zoom system, the final zoom system equipped with this expander doubles the focal length ranges and has stable performance over a specified temperature range.

Numerical Analysis of Working Distance of Square-shaped Beam Homogenizer for Laser Shock Peening

  • Kim, Taeshin;Hwang, Seungjin;Hong, Kyung Hee;Yu, Tae Jun
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.221-227
    • /
    • 2017
  • To apply a square-shaped beam homogenizer to laser shock peening, it should be designed with a long working distance and by considering metal targets with various shapes and textures. For long working distances, a square-shaped beam homogenizer with a long depth of focus is required. In the range of working distance, the laser beam is required to have not only high efficiency but high uniformity, in other words, a good peening quality is guaranteed. In this study, we defined this range as the working distance for laser shock peening. We have simulated the effect of some parameters on the working distance. The parameters include the focal length of the condenser lens, pitch size of the array lens, and plasma threshold of the metal. The simulation was performed through numerical analysis by considering the diffraction effect.

Optical Approach for Increasing the Resolution of Displayed Multi-view Image from Projection Type of Auto-stereoscopic 3D Display System by Adopting a Commercial Spherical Lenticular Lens Sheet (프로젝션 기반 무안경 방식 멀티뷰 3D 디스플레이에서 구면 렌티큐라 렌즈 시트를 이용하여 재생된 입체영상의 해상도를 증가시키는 광학적 접근 방법)

  • Sohn, Young-Sub;Kim, Sung-Kyu;Sohn, Kwanghoon;Lee, Kwang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.147-153
    • /
    • 2012
  • Multi-view 3D displays based on a limited number of pixels have the problem that the stereo-scopic image has a low resolution because of increasing view number. To solve the problem of low resolution, we propose an optical approaching method that focuses the width of a unit pixel by using a commercial spherical shape lenticular lens sheet and increases the effective resolution by increasing the number of sources of light in the multi-view 3D display system based on projection type. The method was performed in such an order that several main derivable parameters were defined, and, through the theoretical and experimental result, the value of the contractible unit pixel width and the scalable effective resolution was derived in a given system environment. As a result, for the case that the ray of light from the projector transmitted the 25 LPI lenticular lens sheet which has the pitch size 1.016 mm, the focused unit pixel width was 0.19 mm and the scalable effective resolution was, at most, 5 times wider than the original one. In addition, the range of depth of focus was 1.496 mm, which shows us the range of thickness tolerances of commercial spherical shape lenticular lens sheet and sufficient optical alignment tolerances.

A New Focus Measure Method Based on Mathematical Morphology for 3D Shape Recovery (3차원 형상 복원을 위한 수학적 모폴로지 기반의 초점 측도 기법)

  • Mahmood, Muhammad Tariq;Choi, Young Kyu
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Shape from focus (SFF) is a technique used to reconstruct 3D shape of objects from a sequence of images obtained at different focus settings of the lens. In this paper, a new shape from focus method for 3D reconstruction of microscopic objects is described, which is based on gradient operator in Mathematical Morphology. Conventionally, in SFF methods, a single focus measure is used for measuring the focus quality. Due to the complex shape and texture of microscopic objects, single measure based operators are not sufficient, so we propose morphological operators with multi-structuring elements for computing the focus values. Finally, an optimal focus measure is obtained by combining the response of all focus measures. The experimental results showed that the proposed algorithm has provided more accurate depth maps than the existing methods in terms of three-dimensional shape recovery.

A Fuzzy Search Method for Auto Focusing of CCM Test Handlers (CCM 테스트 핸들러의 자동초점조절을 위한 퍼지탐색 방법)

  • Kwon, Hyuk-Joong;Yoon, Hee-Sang;Park, Tae-Hyoung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1112-1118
    • /
    • 2007
  • We propose a new-focusing method for test handlers of compact camera module (CCM), The MMD (max-min difference) method is applied to calculate the focus value quickly considering the noisy output of CCM. Also, the fuzzy search method is applied to find the maximum focus value effectively. We design a fuzzy processor to control the lens position by focus values and brightness values, which improves the focusing performance in the sense of speed and processor memory. The proposed method is implemented by computer program and installed at the CCM test handler machines. The simulation results are presented to verify the usefulness of the proposed method.

Fabrication technology of the Diffractive Optical Head for optical recoding information storage (광기록 정보저장용 Diffractive Optical Head 제작 연구)

  • Han, Gee-Pyeong;Kim, Tae-Youb;Sohn, Yeung-Joon;Kim, Yark-Yeon;Paek, Mun-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.992-993
    • /
    • 2002
  • We have fabricated the diffractive optical head(DOH) for optical pick up, which one adaptable to a optical recoding information storage. DOH consists of a focusing grating coupler(FGC) and a solid immersion Jens(SIL). FGC is device that the light converge into a focus by surface lattice. FGC have been studied as a potential application of pick up head for the information storage. In this study, FGC was designed and fabricated to make focus near to possible diffraction limit. We also fabricated recording head combined with SIL. The focus was measured in the range of $1.1{\mu}m$ as near to possible diffraction limit in the FGC having a focusing length of $600{\mu}m$ and a lattice area of 500 * $500{\mu}m$.

  • PDF

A Fuzzy Search Method for Auto Focusing of CCM Test Handlers (CCM 테스트핸들러의 자동초점조절을 위한 피지탐색 방법)

  • Kwon, Hyuk-Joong;Yoon, Hee-Sang;Park, Tae-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.123-126
    • /
    • 2006
  • We propose a new-focusing method for test handlers of compact camera module (CCM), The MMD (max-min difference) method is applied to calculate the focus value quickly considering the noisy output of CCM. Also, the fuzzy search method is applied to find the maximum focus value effectively. We design a fuzzy processor to control the lens position by focus values and brightness values, which improves the focusing performance in the sense of speed and processor memory. The proposed method is implemented by program and installed at the CCM test handler machines. The simulation results are presented to verify the usefulness of the proposed method.

  • PDF

A Study on Measuring the Shape of Transparent Objects using the Focal Area of Hologram Optical System (홀로그램 광학계의 초점영역을 이용한 투명 물체의 형상 측정에 관한 연구)

  • Byun, Jong-Hwan;Ryu, Young-Kee;Oh, Choon-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.600-602
    • /
    • 2005
  • Recently image display devices have become large and high quality. To control the qualities of the component, measurements of the shape and thickness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens used for CD Player, and the sensor showed high performance for measuring the shape and thickness of transparent plates. In the sensor, the temperature of the sensor body is controlled by TEC(Thermoelectric Cooler). In this paper, we proposed the measuring method to make better performance of sensor using focus error signal of a hologram laser unit. It can measure the shape and the thickness of transparent objects with the s-type focus error signal which is generated by the sensor while it goes to the object.

  • PDF

A Study of the Retina Image Controllability using a Sledge (망막 영상 조절 장치에 관한 연구)

  • 이숙희;이영춘;양연식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.273-276
    • /
    • 1997
  • Seeing is an intelligent act. Retina is the most important part among the components of eye which is comprised of iris, pupil, lens, optic disk, and so forth. Because retina acts like a photo receiver to detect light from every object, if damaged, animals have a severe problem to live along with themselves and sometimes they lose their sight. In the ophthalmology, doctors use special instrument to see exact retina image of object and operate the surgery by rotating focus control knob. In this study, a basic test is done to achieve the auto focus control instrument. Specially made sledge and attenuator are installed on the optic bed to change the distance and laser power between the first reflective mirror and the second one. Control panel which is compiled by Visual C t t to control stepping motors ,laser power and photodiode are implemented with ADA-board.

  • PDF