• 제목/요약/키워드: foam layer

검색결과 155건 처리시간 0.019초

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

휴대용 TDR 함수량계로 측정한 현장 함수비를 이용한 현장 상온 재활용 아스팔트 포장의 수분 감소계수 개발 (Development of Moisture Loss Index Based on Field Moisture Measurement using Portable Time Domain Reflectometer (TDR) for Cold In-place Recycled Pavements)

  • 김용주;이호신;임수혁
    • 한국도로학회논문집
    • /
    • 제13권2호
    • /
    • pp.139-145
    • /
    • 2011
  • 최근 10년간 전세계적으로 아스팔트 포장을 재활용하는 기술이 급속도로 확산되고 있으며 노후 아스팔트 포장을 폼드 아스팔트 또는 유화 아스팔트를 사용하여 현장에서 바로 100% 재활용하는 현장 상온 재생 아스팔트 포장기술이 다양하게 적용되고 있다. 특히, 아이오와 주에서는 교통량이 적은 지방도로에서 기존 포장의 수명을 연장 시켜주는 현장 상온 재생 아스팔트 공법을 많이 적용하고 있다. 일반적으로 현장 상온 재생 아스팔트 포장층은 수분의 침투나 교통하중으로부터 보호하거나 포장설계를 만족시키기 위해 가열 아스팔트 포장으로 덧씌우기를 한다. 일반적으로 현장 상온 재생 아스팔트 포장층 위에 가열 아스팔트 포장으로 덧씌우기 할 시기는 대부분에 감독자들은 일정한 양생기간 또는 최대 함수비에 근거하여 결정하고 있다. 따라서, 본 연구에서는 감독자가 최적에 덧씌우기 아스팔트 포장 시기를 결정할 수 있도록 현장 상온 재생 아스팔트 포장층의 현장 함수비를 간단하게 측정하여 덧씌우기 시기를 결정할 수 있는 수분 감소계수를 개발하는 것이다. 먼저, 현장 상온 재생 아스팔트 포장층의 함수비를 TDR 함수량계를 사용하여 측정하였고 현장 상온 재생 아스팔트 포장이 시공되는 기간 동안에 강우량, 대기온도, 습도, 바람속도 등 기상정보를 수집하였다. 마지막으로 현장 상온 재생 아스팔트 포장의 초기 함수비, 대기온도, 습도, 바람속도를 변수로 하는 수분 감소계수를 개발하였다. 실제 현장 상온 재생 아스팔트 포장에서 측정한 값을 사용하여 개발한 수분 감소계수는 감독자가 연속적으로 현장 상온 재생 아스팔트 포장층의 함수비를 측정하지 않고 최적의 덧씌우기 포장 시점을 결정할 수 있다.

난류 촉진기 주위 천이 유동의 대형 와 모사를 위한 격자 테스트 (Grid Tests for Large Eddy Simulation of Transitional Flows around Turbulence Stimulators)

  • 이상봉;박동우;백광준
    • 해양환경안전학회지
    • /
    • 제23권1호
    • /
    • pp.112-121
    • /
    • 2017
  • 평판에 설치된 스터드 주위의 천이 유동에 있어 격자 크기의 영향을 알기 위해 대형 와 모사를 수행하였다. 스터드에서 야기되는 주 유동 방향의 와 구조가 스터드 후류의 천이에 미치는 영향이 매우 크기 때문에 주 유동 방향, 벽면 수직 방향 그리고 횡 방향으로 격자 크기를 ${\sqrt{2}}$ 배씩 증가시키거나 감소시키면서 스터드 후류에서 주 유동 방향의 와도를 비교하였다. 그 결과 스터드 후류에서 발달하는 주 유동 방향의 와도는 횡 방향 격자 크기에 매우 큰 영향을 받는 것을 알 수 있었으며, 이러한 결과를 바탕으로 ${\Delta}x^+{_{min}}=7.6$, ${\Delta}x^+{_{max}}=41$, ${\Delta}y^+{_{wall}}=0.25$ and ${\Delta}z^+=7.6$의 격자 크기를 결정하였다. 이러한 격자 구성에 있어 모든 방향으로 격자 크기를 동시에 ${\sqrt{2}}$ 배씩 증가시키거나 감소시키면서 스터드에 작용하는 힘의 변화를 비교하여 격자 검증을 실시한 결과 평균 압력 계수와 항력 계수의 비보정 불확실성이 각각 21.6 %와 2.8 % 정도로 추정되었으며, 보정 불확실성은 각각 2 %와 0.3 %로 추정되었다.

돼지모델에서 상처의 모양과 부위에 따른 상처수축의 특성 (Characteristics of Wound Contraction according to the Shape and Antomical Regions of the Wound in Porcine Model)

  • 추호준;손대구;권선영;김준형;한기환
    • Archives of Plastic Surgery
    • /
    • 제38권5호
    • /
    • pp.576-584
    • /
    • 2011
  • Purpose: The shape and location, the amount of the wound and the characteristics of the remaining tissues are known to influence wound contraction. The previous studies using small animals have not been an appropriate model because the wound healing mechanisms and skin structures are different from those of the human. The purpose of this study is to evaluate wound contraction according to the shape and location of the wound using a $Micropig^{(R)}$. Methods: Four $Micropigs^{(R)}$ (Medikinetics, Pyeongtaek, Korea) that were 10 months of age weighed 25 kg were used. Full thickness skin defects were made by clearing all the tissues above the fascial layer in the shape of square, a regular triangle and a circle of 9 $cm^2$ each on the back around the spine. Eight wounds were created on the back of each pig, 50 mm apart from each other. The randomly chosen wound shapes included 11 squares, 11 regular triangles, and 10 circles. Wound dressing was done every other day with polyurethane foam. The wound size was measured using a Visitrak $Digital^{(R)}$ (Smith & Nephew, Hull, UK) on every other day after surgery from day 2 to day 28. A biopsy was performed on day 3, and 1, 2, 3 and 4 weeks to investigate the degree of acute and chronic inflammation, the number of microvesssel and myofibroblast density using H & E stain and immunohistochemistry. The wound contraction rate was calculated to figure out the differences among each of the shapes and the locations. Results: The ultimate shape of the circle wound was oval, and that of the regular triangle and square were stellate. The maximum contraction rate was obtained on 8 to 10 days for all the shapes, which corresponds with the immunohistochemical finding that myofibroblast increases in the earlier 2 weeks whereas it decreases in the later 2 weeks. Epithelialization was seen in the wound margin on day 7 and afterwards. The final wound contraction rates were highest for the regular triangle shapes; however, there were no statistically significant differences. The wound contraction rates by locations showed statistically significant differences. The wound in the cephalic area presented more contractions than that of the wounds in the caudal area. Conclusion: The location of a wound is more important factor than the wound shape in wound contraction.

현수, 배관 내 혼합 폭기방식 적용이 돼지분뇨 슬러리의 액상 비료화에 미치는 영향 (Effect of the Application of a Suspended and a Mixing-in-Pipe Type Aerator on the Liquid Fertilization of Pig Manure Slurry)

  • 정광화;김중곤;;곽정훈;한덕우
    • 유기물자원화
    • /
    • 제22권4호
    • /
    • pp.62-71
    • /
    • 2014
  • 폭기방식에 따른 돼지분뇨 슬러리의 액비화 효과를 분석하기 위하여 3 가지 형태의 산기방식을 적용하였다. 첫 번째 형태는 기존에 일반적으로 사용되는 산기방식으로서 바닥부분에 고정식으로 설치된 산기장치를 통해 공기를 상향식으로 공급하는 방식이다. 두 번째 방식은 기존 바닥부분 고정 설치식 산기장치를 현수식으로 적용하여 시험용 반응조 바닥으로부터 약 10 cm정도 띄워서 설치하였다. 세번째 방식은 액비조 내의 돼지분뇨 슬러리를 펌프로 흡입하여 다시 액비조로 보내는 순환용 배관에 벤추리 방식의 공기 공급부를 설치하여 배관 내를 흐르는 액비에 공기를 혼합하는 방식의 반응조이다. 고액분리한 돈분뇨 슬러리를 시험용 반응조에 주입 후 1 주일간 정치시켜 고형물을 침전시킨 다음에 폭기 시험을 개시하였다. 바닥 고정식 폭기방식의 반응조에 투입된 원 슬러리 중의 유기물과 T-N, T-P, BOD 농도는 각각 1.82%, 4,400 mg/L, 360 mg/L, 13,542 mg/L 이었으며 폭기 실시 후 채취한 슬러 중의 유기물과 T-N, T-P, BOD 농도는 2.01%, 4,400 mg/L, 420 mg/L, 16,824 mg/L 수준이었다. 본 연구에서 시험용으로 제작, 사용된 배관 내 혼합방식의 시험구에서의 상기 수질분석 항목의 농도는 각각 1.58%, 3.700 mg/L, 260 mg/L, 15,735 mg/L 에서 1.96%, 4,000 mg/L, 340 mg/L, 18,098 mg/L 수준으로 변화하였다. 바닥 폭기방식과 배관 내 혼합방식의 두 가지 폭기조의 중층 부분에서의 측정한 상기 수질분석 항목의 농도는 변화정도는 각각 10.4%, 0%, 16.7%, 24.2%와 24.0%, 8.1%, 30.8%, 15.0% 인 것으로 분석되어 배관 내 혼합방식에서의 혼합효과와 액비조 내 액비성분의 균질도 정도가 상대적으로 더 높은 것으로 분석되었다. 폭기조 표면에 생성되는 거품 층의 두께는 배관 내 혼합방식이 더 얇게 형성되는 결과를 보였다.