• Title/Summary/Keyword: flux sensor

Search Result 347, Processing Time 0.028 seconds

접착형 박막 측온게이지식 열류센서의 개발에 관한 연구

  • 한응교;박두원;최규철;노병옥;이명호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.80-86
    • /
    • 1991
  • In this study an the development of the heat flux sensor with thermocouple, the heat-treated adhesive type film nickel gauge(Ni-Gauge) for measuring temperature was used. and this Ni-Gauge is not only comparable for platinum gauge(Pt-Gauge) in linearity, but also economically cheap. And from this viewpoint. numerical analysis is essential to investigate charateristics of sensor, since this analysis is capable of simulating precise boudary condition and practical conditions and so on. By the way. there are many types of heat flux sensor. of which adhesive type flux sensor is common, in the study this type of heat flux sensor was chogen. and analysis of the sensor is considered as a kind of open cavity figure. performed by SIMPLER algorithm. As a result. through temperature distributial of the sensor by numerical analysis in steady and unsteady state, the dracteristics of the acdhesive type heat flux sensor(lst heat flux sensor) acooodinge to heat flux, that is, outvoltage, sensitivity. and responsibilty could be evaluated. in addition, time of improved heat flux sensor(2nd heat flux sensor) could be predicted fran the reflectian of proper operating temperature(l50 $^{\circ}C$)of theNi-Gauge.

  • PDF

Development of Heat Flux Sensor Using Adhesive Type Film Gauge for Measuring Temperature (접착형 박막 온도측정 게이지식 열전대센서의 개발에 관한 연구)

  • Han, Eung-Kyo;Choi, Gue-Cheol;Rho, Byung-Ok;Park, Too-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.2
    • /
    • pp.52-60
    • /
    • 1992
  • In this study on the development of the heat flux sensor, unlike the common heat-flux sensor with thermocouple, the heat-treated adhesive-tupe film nickel-gauge was used in measuring temperature. The proposed its Ni-gauge is bound to be compatible with platinum gauge(Pt-Gauge) in its linearity. It is also considered to be cheap in economical sense. In the evaluation of it's performance, the numerical analysis is essential to investigate charateristics of proper sensor and the adequate analsis is depended upon boundary conditions and actual conditions. There are many types of heat flux sensor in the market, and adhexive type flux sensor is most common. In the present investigation, this type of heat flux sensor had been chosen. The figure of the sensor under consideration is an open cavity type, which is calculated numerically by SIMPLER algorithm. The temperature distributions of the sensor predicted by numerical calculation for steady and unsteady states are able to give the chacteristics of the adhesive type heat flux sensor(1st heat flux sensor) according to the heat flux. It means that the outvoltage, the sensitivity, and the performances of responsibility could be evaluated as a result. Through this analysis improved heat flux sensor(2nd heat flux sensor) could be predicted with the reflection of proper operating temperature($150^{\circ}C$) of the Ni-gauge.

  • PDF

Modeling of a Non-contact Type Precision Magnetic Displacement Sensor (비접촉식 정밀 변위 측정용 자기센서 모델링)

  • Shin, Woo-Cheol;Hong, Jun-Hee;Lee, Kee-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.42-49
    • /
    • 2005
  • Our purpose is to develop a precision magnetic displacement sensor that has sub-micron resolution and small size probe. To achieve this, we first have tried to establish mathematical models of a magnetic sensor in this paper. The inductance model that presents basic measuring principle of a magnetic sensor is based on equivalent magnetic circuit method. Especially we have concentrated on modeling of magnetic flux leakage and magnetic flux fringing. The induced model is verified by experimental results. The model, including the magnetic flux leakage and flux fringing effects, is in good agreement with the experimental data. Subsequently, based on the augmented model, we will design magnetic sensor probe in order to obtain high performances and to scale down the probe.

Induction motor sensor less speed control by stator flux oriented method (고정자 자속 기준 제어 방식에 의한 속도검출기 없는 유도전동기 속도 제어 시스템)

  • Park, Min-Ho;Kim, Kyoung-Seo;Kim, Heui-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.268-272
    • /
    • 1989
  • To avoid the use of position sensor or flux sensor in a field oriented induction machine drive system, the terminal quantities are often used to estimate the rotor flux. Since the estimation involves the leakage inductance of the machine, the performance of such systems is sensitive to the variations of leakage. Since estimation of the stator flux is independent of the leakage, the steady state performance of the stator flux oriented system is insensitive to the leakage inductance. In this paper, the torque response of stator flux oriented system is compared to that of rotor flux oriented system by digital simulation. And induction motor sensor less speed control by stator flux oriented method is developed. The performance of the speed estimation is showed by digital simulation.

  • PDF

The Micro Heat Flux Sensor using Electroplated Copper layers (구리 도금층을 이용한 미세 열유속 센서)

  • 오석환;전재철;김무환;이승섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.226-231
    • /
    • 2000
  • New types of the micro heat flux sensor are designed and fabricated using SU-8 and Cu electroplating. And then calibrated under convection environment. The thermal path was made by SU-8 structure and electroplated Cu layers. The bottom surface of the micro heat flux sensor receives the heat flux from the wall, Then the heat flows along the Cu layers and drains out to the environment with producing the temperature difference at the upper layer of Cu. By measuring this temperature difference, the heat flux from the wall can be obtained. The temperature difference is measured by thermopile which is composed of Ni-Cr pairs or Al-chromel pairs. The calibration is accomplished under convection environment because it is most frequent situation. The range of the sensitivity is 0.11~2.02$\mu$V/(㎽/$\textrm{cm}^2$) for the various heat flux and Reynolds numbers.

  • PDF

Development of Micro-machined Heat Flux Sensor by using MEMS technology (MEMS를 이용한 미세 열유속센서의 개발)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1364-1369
    • /
    • 2004
  • New method for the design, fabrication, and calibration of micro-machined heat flux sensor has been developed. Two types of micro-machined heat flux sensor having different thicknesses of the thermal-resistance layer are fabricated using the MEMS technique. Photo-resist patterning using a chrome mask, bulk-etching and copper-nickel sputtering using a shadow mask are applied to make heat flux sensors, which are calibrated in the convection-type heat flux calibration facility. The sensitivity of the device varies with thermal-resistance layer, and hence can be used to measure the heat flux in heat-transfer phenomena.

  • PDF

Design of The Micro Fluidic Heat Flux Sensor (유동형 미세 열유속 센서의 설계)

  • Kim, Jung-Kyun;Cho, Sung-Cheon;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.138-145
    • /
    • 2009
  • A suspended membrane micro fluidic heat flux sensor that is able to measure the heat flow rate was designed and fabricated by a complementary-metal-oxide-semiconductor-compatible process. The combination of a thirty-junction gold and nickel thermoelectric sensor with an ultralow noise preamplifier, low pass filter, and lock-in amp has enabled the resolution of 50 nW power and provides the sensitivity of $11.4\;mV/{\mu}W$. The heater modulation method was used to eliminate low frequency noises from sensor output. It is measured with various heat flux fluid of DI-water to test as micro fluidic application. In order to estimate the heat generation of samples from the output measurement of a micro fluidic heat-flux sensor, a methodology for modeling and simulating electro-thermal behavior in the micro fluidic heat-flux sensor with integrated electronic circuit is presented and validated. The electro-thermal model was constructed by using system dynamics, particularly the bond graph. The electro-thermal system model in which the thermal and the electrical domain are coupled expresses the heat generation of samples converts thermal input to electrical output. The proposed electro-thermal system model shows good agreement with measured output voltage response in transient state and steady-state.

Fabrication and evaluation of a micro heat flux sensor using thermopile (열전대를 이용한 미세 열유속 센서의 제작 및 평가)

  • Kim Jung-Hoon;Kim Bum-Seok;Cho Hyung-Hee;Kim Yong-Jun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1210-1213
    • /
    • 2005
  • Micro heat flux sensor is used in various industries to measure heat flux. In this study, a micro heat flux sensor is fabricated using the MEMS (Micro Electro Mechanical Systems) techniques. The fabricated sensor is composed in thermopile for sensor and SU-8 for thermal resistance layer. The new method of fabrication SU-8 is proposed in this study. The sensitivity is $44\;\mu{V/(W/cm^2)}$ at steady state and Reynolds number is 91322.

  • PDF

Modeling of a Superconducting Flux Flow Sensor Inductance Radiometer (인덕턴스 복사계 측정을 위해 사용된 초전도 자속 흐름 센서기 모델링)

  • Ko, Seok-Cheol;Kang, Hyeong-Gon;Lim, Sung-Hun;Choi, Myong-Ho;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.19-22
    • /
    • 2003
  • For use in constructing highly sensitive thermal detectors, the present authors have been studying the preparation of Superconducting Flux Flow Sensor(SFFS). In this research, SFFS with five channel ($5{\mu}m$/1channel) has been fabricated based on the flux flow using high temperature superconducting thin films by the ICP etching technique. We have designed a bolometer based on the temperature dependence of the kinetic inductance of a superconducting flux flow thin film. In this paper examines the fabrications and flux flow resistance and thermometer responses of the highly sensitive sensor constructed of a thin YBCO film. It is also suggested that they will be applicable to a new type of flux flow sensor.

  • PDF

A Study on Calibration of Heat Flux Sensor by using Convective Heat Transfer (대류방식을 이용한 열유속센서의 검정에 관한 연구)

  • Yang, Hoon-Cheul;Song, Chul-Hwa;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1358-1363
    • /
    • 2004
  • The objective of this work is to propose calibration facility in which a thin film type heat flux sensor can be calibrated under convective flow condition by using a small wind tunnel with the constant temperature plate condition. A small wind tunnel has been built to produce a boundary layer shear flow above a constant temperature copper plate. 12-independent copper blocks, thin film heaters, insulators and temperature controllers were used to keep the temperature of flat plate constant at a specified temperature. Three commercial thin film-type heat flux sensors were tested. Convective calibrations of these gages were performed over the available heat flux range of $1.4{\sim}2.5kW/m^2$. The uncertainty in the heat flux measurements in the convective-type heat flux calibration facility was ${\pm}2.07%$. Non-dimensional sensitivity is proposed to compare the sensitivity calibrated by manufacturer and that of experiment conducted in this study.

  • PDF