• 제목/요약/키워드: flux method

검색결과 2,888건 처리시간 0.026초

동기형 릴럭턴스 전동기의 단순구조형 센서리스 제어의 저속운전 (Low Speed Operation of Simplified Sensorless Control of Synchronous Reluctance Motor)

  • 안준선;이주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권2호
    • /
    • pp.61-68
    • /
    • 2006
  • Many researchers have worked for the sensorless control of SynRM in recent years. However they commonly requires large calculations which induced from its complexity. For low cost application as like home appliance, it is difficult to utilize because of the cost problem. Therefore, it is necessary to introduce simplified sensorless control scheme that is composed of least calculation to estimate the rotor position. In this paper the sensorless control is performed using the characteristics of SynRM structure in which the linkage flux varies with rotor position, so the rotor position can be detected by the change of linkage flux. The estimation of linkage flux can be acquired from the integration of the motor terminal voltage which is commonly used method for the reliability of the estimation. However this estimation method has demerits in low speed operation therefore in that region the motor terminal voltage is compensated by the phase current. A digital simulation (MATLAB) and experiment were performed to confirm the adequacy of the proposed control scheme.

자속 측정을 통한 유도전동기의 회전자 바 손상 검출기법 (Detecting Method for Broken Rotor Bar of Induction Motors by Flux Measurement)

  • 황돈하;한상보;강동식;김병국;김미정;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.827-828
    • /
    • 2006
  • This paper proposes a new method for detecting broken rotor bars in a squirrel-cage induction motor. The air-gap flux variation analysis was done using search coils inserted in stator slots when broken rotor bar occurs. An accurate modeling and analysis of air-gap flux variation in the induction motor are developed using finite-element(FE) software packages, and measurement of the flux are made using search coils. The simulation was done for the induction motor with 380 [V]. 7.5 [kW], 4 Poles, 1,760 [rpm] ratings using the commercial FE analysis tool. The simulation and experiment results can be useful for detecting the broken rotor bar of an induction motor.

  • PDF

A Study on the Iron Losses in Flux-Switching Permanent Magnet Machines

  • Shin, Heung-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.699-703
    • /
    • 2018
  • Flux-switching permanent magnet machines (FSPMM) have doubly-salient and simple structures making it cost effective and suitable for mass production. In addition, it is possible to increase the rotor rotating speed and concentrate the flux of the permanent magnet on the air-gap. Due to these merits, the FSPMM can be applied to the various industry applications. To improve the performance, various design variables need to be studied in terms of design techniques. In this paper, we especially concentrate on the distribution of iron losses using a two-dimensional finite-element method (2D FEM). As a result, we can get an information for high efficiency FSPMM design.

A Study on Sensorless Control of Transverse Flux Rotating Motor Based on MRAS with Parameter Estimation

  • Kim, Ji-Won;Kim, Kwang-Woon;Kisck, Dragos Ovidiu;Kang, Do-Hyun;Chang, Jung-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.864-869
    • /
    • 2011
  • This paper presents a sensorless control and parameter estimation strategies for a Transverse Flux Rotating Motor (TFRM). The proposed sensorless control method is based on a Model Reference Adaptive System (MRAS) to estimate the stator flux. Parameter estimation theory is also applied into the sensorless control method to estimate motor parameters, such as inductances. The effectiveness of the proposed methods is verified by some simulations and experiments.

3차원 유한요소법에 의한 2상 8극 HB형 LPM의 가동자의 자속분포 해석 (Analysis of Flux Distribution in 2 Phase 8 Pole HB type LPM by 3D FEM)

  • 이동주;이은웅;김성헌;김성종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1999
  • 2 phase 8 pole HB type LPM(linear pulse motor) has the suitable structure for it's microstep drive. Hence, if this LPM will be drived by this method, the limited(mechanically) step resolution can be increased further and vibration and noise can be decreased considerably. But, It is difficult that this LPM was analyzed in detail because of it's complex magnetic circuits to be composed the LF(longitudinal flux) and TF(transverse flux.) path. If LPM was analyzed by the approximate 2D model, we could not be obtained satisfactory result. Therefore, It is necessary to be analyzed the 3D model in detail for the more satisfactory results. In this paper, we obtain 3D flux distribution of the mover using by 3D FEM(finite element method)

  • PDF

밑면에 균일 열유속이 존재하는 밀폐공간에서의 복사 - 자연대류열전달 (Combined Radiation and Natural Convection Heat Transfer in an Enclosure with a Constant Heat Flux at the Bottom)

  • 권순석;권용일
    • 태양에너지
    • /
    • 제12권2호
    • /
    • pp.28-42
    • /
    • 1992
  • This investigation is carried out numerically for the two dimensional natural convection and surface radiation heat transfer in a square enclosure. The bottom wall is a constant heat flux at hot temperature and also top wall is isothermal at cold temperature whereas the left and right side walls are adiabatic except a transparent window on the right side partially. The exchange of radiant energy is obtained by the net radiation method and the shape factor by the crossed string method. The change in temperature and Nusselt number distributions of the walls due to the effect of the wall emissivity for various emissivities and for various dimensionless insolation energies are investigated. The dimensionless local convective heat flux and local radiative heat flux distributions in the wall except an adiabatic wall are also compared.

  • PDF

프로그램어블 고역필터를 사용한 직접 벡터제어 유도전동기 구동시스템의 고정자 자속 계산 (A Programmable High-Pass Filter Based Stator Flux Estimation for a Direct Vector Controlled Induction Motor Drive System)

  • 전태원;최명규
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권1호
    • /
    • pp.48-53
    • /
    • 2000
  • The novel integration method with programmable high-pass filter is suggested in order to solve the problem of integration for stator flux estimation in a stator flux oriented direct vector controlled induction motor drive system. The dc offset in a pure integrator is eliminated using high-pass filter with fixed time constant, and then time constant of programmable high-pass filter is controlled with a inverter frequency for integration in a wide frequency range, considering phase lag and attenuation due to both the hardware low-pass filter and high-pass filter. The proposed method is verified with the experimental results implemented by 32-bit DSP.

  • PDF

Simple Analysis Method for the Interrupting Capability of a Contact System in a Molded Case Circuit Breaker

  • Choi, Young-Kil;Jee, Seung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1257-1261
    • /
    • 2017
  • This paper focuses on understanding the interrupting capability of an arc contact system in a molded case circuit breaker (hereafter MCCB). We selected four types of MCCBs and analyzed the magnetic flux density distributions in the contact systems caused by the fault currents. We ascertained that the magnetic flux density profile varies according to the shape of the contact system and was asymmetric at both the ends of an arc, perpendicular to the arc column because of the magnetic grid installed in the contact system. The asymmetric difference creates a magnetic force that pushes the arc current outwards and provides an interrupting capability. We have introduced a simple analysis method for determining the interrupting capability of the contact system for an MCCB by the arc-driving magnetic flux density.

Solid type 요크를 사용하는 횡자속 전동기의 철손해석 (Iron Loss Analysis of Transverse Flux Linear Motor using Solid type Yoke)

  • 이지영;홍정표;장정환;강도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1055-1057
    • /
    • 2004
  • This paper deals with a qualitative analysis of iron loss in Transverse Flux Linear Motor (TFLM). 3D equivalent magnetic circuit network method (EMCNM) is used as an analytical method to get flux density of each element. The total core loss is calculated with the magnetic flux density and core loss curves of an optional material. The results of iron loss analysis can be used as a criterion to decide the manufactural shape such as lamination or solid type core, skew position, etc.

  • PDF

해석적 방법을 통한 X-Y 리니어 모터의 특성해석에 관한 연구 (A study of characteristic analysis of X-Y linear motor using analysis method)

  • 이동엽;황예;한광규;김규탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.29-31
    • /
    • 2005
  • The effective flux of X-Y linear motor is calculated with analytical method according to the arrangement of permanent magnet. In order to reduce leakage flux due to increased effective flux, the distance of the permanent magnet is adjusted. When the distance is 2[mm] between two magnets, the leakage flux is greatly reduced, and it is expected that if the segment of permanent magnet magnetized to x and y direction is added, the motor performance will be enhanced.

  • PDF