• Title/Summary/Keyword: fluorine

Search Result 777, Processing Time 0.027 seconds

Synthesis and Evaluation of F-18 Labeled 2'-Deoxy-2'-fluoro-5-methyl-1-β-L-arabinofuranosyluracil (L-[18F]FMAU)

  • Jo, Nam-Hyun;Moon, Byung-Seok;Hong, Su-Hee;An, Gwang-Il;Choi, Tae-Hyun;Cheon, Gi-Jeong;Cho, Jung-Hyuck;Yoo, Kyung-Ho;Lee, Kyo-Chul;Oh, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2449-2453
    • /
    • 2007
  • L-[18F]FMAU ([18F]1b) was prepared from the precursor 2-O-[(trifluoromethyl)-sulfonyl]-1,3,5-tri-Obenzoyl- α-L-ribofuranose, by coupling the radioactive fluoro-sugar with the corresponding silylated thymine in 4 steps. The final products, including the α and β anomers, were purified using reverse phase HPLC with an appropriate solvent (5% CH3CN/H2O) at a flow rate of 3.0 mL/min. The total elapsed time of synthesis was about 180-200 min from EOB. The α/β anomeric ratio of the compounds was about 1:9, and the radiochemical purity of the product (β-form) was >98% with decay-corrected yields of 25-35%. All radioactive samples were confirmed using co-injection with pure non-radioactive analogues in every step. In the cellular uptake in vitro test of herpes simplex virus-thymidine kinase (HSV1-TK) gene expressed cells, the percent uptake of injected dose (%ID) of L- and D-FMAU was 37.28 and 65.86, respectively after 240 min incubation. However, the relative uptake (MCA-TK/MCA cellular uptake ratio) of L-FMAU was higher than that of D-FMAU (%ID of L-FMAU, 0.36 and D-FMAU, 0.93 after 240 min incubation in MCA cells). This means that L-FMAU will show better specific HSV1-TK gene expressed cell uptake for selective HSV1-TK gene imaging.

Enhancement of PLED lifetime using thin film passivation with amorphous Mg-Zn-F

  • Kang, Byoung-Ho;Kim, Do-Eok;Kim, Jae-Hyun;Seo, Jun-Seon;Kim, Hak-Rin;Lee, Hyeong-Rag;Kwon, Dae-Hyuk;Kang, Shin-Won
    • Journal of Information Display
    • /
    • v.11 no.1
    • /
    • pp.8-11
    • /
    • 2010
  • In this study, a new thin films passivation technique using Zn with high electronegativity and $MgF_2$, a fluorine material with better optical transmittance than the sealing film materials that have thus far been reported was proposed. Targets with various ratios of $MgF_2$ to Zn (5:5, 4:6 and 3:7) were fabricated to control the amount of Zn in the passivation films. The Mg-Zn-F films were deposited onto the substrates and Zn was located in the gap between the lattices of $MgF_2$ without chemical metathesis in the Mg-Zn-F films. The thickness and optical transmittance of the deposited passivation films were approximately 200 nm and 80%, respectively. It was confirmed via electron dispersive spectroscopy (EDS) analysis that the Zn content of the film that was sputtered using a 4:6 ratio target was 9.84 wt%. The Zn contents of the films made from the 5:5 and 3:7 ratio targets were 2.07 and 5.01 wt%, respectively. The water vapor transmission rate (WVTR) was determined to be $38^{\circ}C$, RH 90-100%. The WVTR of the Mg-Zn-F film that was deposited with a 4:6 ratio target nearly reached the limit of the equipment, $1\times10^{-3}\;gm^2{\cdot}day$. As the Zn portion increased, the packing density also increased, and it was found that the passivation films effectively prevented the permeation by either oxygen or water vapor. To measure the characteristics of gas barrier, the film was applied to the emitting device to evaluate their lifetime. The lifetime of the applied device with passivation was increased to 25 times that of the PLED device, which was non-passivated.

Fabrication of Si Nano Dots by Using Diblock Copolymer Thin Film (블록 공중합체 박막을 이용한 실리콘 나노점의 형성)

  • Kang, Gil-Bum;Kim, Seong-Il;Kim, Young-Hwan;Park, Min-Chul;Kim, Yong-Tae;Lee, Chang-Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.2 s.43
    • /
    • pp.17-21
    • /
    • 2007
  • Dense and periodic arrays of holes and Si nano dots were fabricated on silicon substrate. The nanopatterned holes were approximately $15{\sim}40nm$ wide, 40 nm deep and $40{\sim}80\;nm$ apart. To obtain nano-size patterns, self?assembling diblock copolymer were used to produce layer of hexagonaly ordered parallel cylinders of polymethylmethacrylate (PMMA) in polystyrene(PS) matrix. The PMMA cylinders were degraded and removed with acetic acid rinse to produce a PS. $100\;{\AA}-thick$ Au thin film was deposited by using e-beam evaporator. PS template was removed by lift-off process. Arrays of Au nano dots were transferred by using Fluorine-based reactive ion etching(RE). Au nano dots were removed by sulfuric acid. Si nano dots size and height were $30{\sim}70\;nm$ and $10{\sim}20\;nm$ respectively.

  • PDF

A Study on the Oral Healthcare Condition of Adult in Public Health and Their Knowledge about Oral Health (계속적인 건강관리를 하는 성인들의 구강건강관리실태 및 구강보건지식에 관한 연구)

  • Jung, Mee-Hee;Park, Mi-Young
    • Journal of dental hygiene science
    • /
    • v.7 no.2
    • /
    • pp.73-79
    • /
    • 2007
  • The purpose of this survey research was to investigate the relationship between the health promotion and the Oral Health knowledge of 230 adults which lived in Kyunggi-do using SPSSWIN 12.0. The following conclusions were obtained. 1. Objects who take the periodic health examination was 38.2% and the opposite case was 61.8%. And the reseach subjects who take the periodic dental examination was 30.7% and the opposite case was 69.3%. 2. The research subjects who take the Oral Health education was 11.8% and the opposite case was 88.2%. 3. The relationship between the general characteristic and health promotion status of the research subjects taking periodic examination showed statistically significant difference at items of ages, occupation and the reason of training (p < 0.05). 4. In case of the relationship of the Oral Health knowledge according to sex distinction, 68.4% of all research subjects thought that the appropriate toothbrushing time was around 3 minutes, but it did not show significant difference statistically. 5. In case of the Oral Health knowledge according to age, it showed significant difference statistically at item of 'the toothbrushing time is after each meal and before retiring (p = .032)', item of 'if you use the fluorine, you can prevent the dental caries (p = .011)', and item of 'foods causing the dental caries are a chocholate and a biscuit, etc. (p-.044). 6. In case of the Oral Health knowledge according to the occupation, 68.4% of all reasearch subjects thought that the appropriate toothbrushing time was around 3 minutes (p = .043), and it showed significant difference statistically. 7. In case of he relationship between reseach subjects taking the periodic examination and the Oral Health knowledge, it did not show significant difference statistically.

  • PDF

Production of $^{11}C$ labeled Radiopharmaceuticals using $[^{11}C]CO_2$ Produced in the KOTRON-13 (한국형 사이클로트론(KOTRON-13)을 이용한 $[^{11}C]CO_2$ 생산과 다양한 $^{11}C$-표지 방사성의약품 생산 적용)

  • Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.

  • PDF

Sn-Ag-Cu Solder Joint Properties on Plasma Coated Organic Surface Finishes and OSP (플라즈마 유기막과 OSP PCB 표면처리의 Sn-Ag-Cu 솔더 접합 특성 비교)

  • Lee, Tae-Young;Kim, Kyoung-Ho;Bang, Jung-Hwan;Park, Nam-Sun;Kim, Mok-Soon;Yoo, Sehoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.25-29
    • /
    • 2014
  • Plasma organic thin film for PCB surface finish is a potential replacement of the conventional PCB finishes because of environment-friendly process, high corrosion-resistance and long shelf life over 1 year. In this study, solder joint properties of the plasma organic surface finish were estimated and compared with OSP surface finish. The plasma surface finish was deposited by chemical vapor deposition from fluorine-based precursors. The thickness of the plasma organic coating was 20 nm. Sn-3.0Ag-0.5Cu (SAC305) solder was used as solder joint materials. From a salt spray test, the plasma organic coating had higher corrosion resistance than the OSP surface finish. The spreadability of SAC305 on plasma organic coating was higher than that on OSP surface finish. SEM and TEM micrographs showed that the interfacial microstructure of the plasma surface finish sample were similar to that of the OSP sample. Solder joint strength of the plasma finish sample was also similar to that of the OSP finished sample.

Performance and reusability of certified and uncertified face masks (보건용 마스크 초미세먼지 제거 성능 평가 및 재사용 연구)

  • Lee, Haebum;Kim, Seojeong;Joo, HungSoo;Cho, Hee-joo;Park, Kihong
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.191-202
    • /
    • 2019
  • In this study, performance (particle removal efficiency and breathing resistance) of several commercially available face masks (electrostatic filter masks (KF80 certified), a nanofiber filter mask (KF80 certified), and an uncertified mask) with their filter structure and composition were evaluated. Also, effects of relative humidity (RH) of incoming air, water and alcohol exposure, and reusability on performance of face masks were examined. Monodisperse and polydisperse sodium chloride particles were used as test aerosols. Except the uncertified mask filter, PM2.5 removal efficiency was found to be higher than 90%, and the nanofiber filter mask had the highest quality factor due to the low pressure drop and high removal efficiency (nanofibers were arranged in a densely packed pore structure and contained a significant amount of fluorine in addition to carbon and oxygen). In the case of the KF80 certified mask, the removal efficiency was little affected when the RH of incoming air increased. When the mask filters were soaked in water, the removal efficiency of mask filters was degraded. In particular, the uncertified mask filter showed the highest removal efficiency degradation (26%). When the mask was soaked in alcohol, the removal efficiency also decreased with the greater degree than the water soaking case. The nanofiber mask filter showed the strongest resistance to alcohol exposure among tested mask filters. During evaluation of reusability of masks in real life, the removal efficiency of certified mask filter was less than 4% for 5 consecutive days (2 hours per day), while the removal efficiency of uncertified mask filter significantly decreased by 30% after 5 days.

Significance of Hormone Receptor Status in Comparison of 18F -FDG-PET/CT and 99mTc-MDP Bone Scintigraphy for Evaluating Bone Metastases in Patients with Breast Cancer: Single Center Experience

  • Teke, Fatma;Teke, Memik;Inal, Ali;Kaplan, Muhammed Ali;Kucukoner, Mehmet;Aksu, Ramazan;Urakci, Zuhat;Tasdemir, Bekir;Isikdogan, Abdurrahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.387-391
    • /
    • 2015
  • Background: Fluorine-18 deoxyglucose positron emission tomography computed tomography (18F-FDG-PET/CT) and bone scintigraphy (BS) are widely used for the detection of bone involvement. The optimal imaging modality for the detection of bone metastases in hormone receptor positive (+) and negative (-) groups of breast cancer remains ambiguous. Materials and Methods: Sixty-two patients with breast cancer, who had undergone both 18F-FDG-PET/CT and BS, being eventually diagnosed as having bone metastases, were enrolled in this study. Results: 18F-FDG-PET/CT had higher sensitivity and specificity than BS. Our data showed that 18F-FDGPET/CT had a sensitivity of 93.4% and a specificity of 99.4%, whiel for BS they were 84.5%, and 89.6% in the diagnosis of bone metastases. ${\kappa}$ statistics were calculated for 18F-FDGPET/CT and BS. The ${\kappa}$-value was 0.65 between 18F-FDG-PET/CT and BS in all patients. On the other hand, the ${\kappa}$-values were 0.70 in the hormone receptor (+) group, and 0.51 in hormone receptor (-) group. The ${\kappa}$-values suggested excellent agreement between all patient and hormone receptor (+) groups, while the ${\kappa}$-values suggested good agreement in the hormone receptor (-) group. Conclusions: The sensitivity and specificity for 18F-FDG-PET/CT were higher than BS in the screening of metastatic bone lesions in all patients. Similarly 18F-FDG-PET/CT had higher sensitivity and specificity in hormone receptor (+) and (-) groups.

Diagnostic Accuracy of 18F-FDG-PET in Patients with Testicular Cancer: a Meta-analysis

  • Zhao, Jing-Yi;Ma, Xue-Lei;Li, Yan-Yan;Zhang, Bing-Lan;Li, Min-Min;Ma, Xue-Lei;Liu, Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3525-3531
    • /
    • 2014
  • Objective: Fluorine-18-fluorodeoxyglucose positron emission tomography (18F-FDG-PET) is a new technique for identifying different malignant tumors using different uptake values between tumor cells and normal tissues. Here we assessed the diagnostic accuracy of 18F-FDG-PET in patients with testicular cancer by pooling data of existing trials in a meta-analysis. Methods: PubMed/MEDLINE, Embase and Cochrane Central Trials databases were searched and studies published in English relating to the diagnostic value of FDG-PET for testicular cancer were collected. The summary receiver operating characteristic (SROC) curve was used to examine the FDG-PET accuracy. Results: A total of 16 studies which included 957 examinations in 807 patients (median age, 31.1 years) were analyzed. A meta-analysis was performed to combine the sensitivity and specificity and their 95% confidence intervals (CIs), from diagnostic odds ratio (DOR), positive likelihood ratios (PLR), negative likelihood ratio (NLR). SROC were derived to demonstrate the diagnostic accuracy of FDG-PET for testicular cancer. The pooled sensitivity and specificity were 0.75 (95% confidence interval (CI), 0.70-0.80) and 0.87 (95% CI, 0.84-0.89), respectively. The pooled DOR was 35.6 (95% CI, 12.9-98.3). The area under the curve (AUC) was 0.88. The pooled PLR and pooled NLR were 7.80 (95% CI, 3.73-16.3) and 0.31 (95% CI, 0.23-0.43), respectively. Conclusion: In patients with testicular cancer, 18F-FDG-PET demonstrated a high SROC area, and could be a potentially useful tool if combined with other imaging methods such as MRI and CT. Nevertheless, the literature focusing on the use of 18F-FDG-PET in this setting still remains limited.

Study on enhanced electron emission current of carbon nanotube by thermal and HF treatments (열 및 불산 처리를 통한 탄소나노튜브의 전자 방출 특성의 향상 연구)

  • Kim, K.S.;Ryu, J.H.;Lee, C.S.;Lim, H.E.;Ahn, J.S.;Jang, J.;Park, K.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.2
    • /
    • pp.90-95
    • /
    • 2008
  • We studied the effect of thermal annealing and hydrofluoric (HF) acid treatment on the field emission properties of carbon nanotube field emitter arrays (CNT-FEAs) grown with the resist-assisted patterning (RAP) process. After thermal and HF treatment, it was observed that the electron emission properties were remarkably improved. The enhanced electron emission was also found to depend strongly on the sequence of the treatments; the electronemission current density is 656 $mA/cm^2$ with the process of thermal treatment prior to HF treatment while the current density is reduced by 426 $mA/cm^2$ with the reversal processes. This is due to the increased crystalline structure by thermal annealing and then strong fluorine bond was formed by HF treatment.