• Title/Summary/Keyword: fluoride-containing resin

Search Result 18, Processing Time 0.029 seconds

COMPARATIVE STUDY ON THE FLUORIDE RELEASE AND COMPRESSIVE STRENGTH OF SEVERAL F-CONTAINING RESTORATIVE MATERIALS (수종의 불소 함유 수복재의 불소 유리 및 압축 강도에 관한 연구)

  • Park, Jee-Young;Kim, Jong-Soo;Kim, Seung-Oh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.469-476
    • /
    • 2008
  • This study was performed to compare the fluoride release pattern and compressive strength of recently developed resin-modified glass ionomers($Ketac^{TM}$ N 100 and Fuji Fil LC) with those of conventional glass ionomer restorative material(Fuji II LC). Fifteen sample discs(6 mm diameter and 1 mm height) were prepared for each tested material. The fluoride release was measured by pH/ISE meter(750P, Istek, Korea) for 31 days. For compressive strength experiment, fifteen cylindrical specimens were prepared for each tested material. Each specimen was submitted to compressive strength testing in an universal testing machine(Kyung-sung Testing Machine Co., Korea) at crosshead speed of 5.0mm/min until failure. The results can be summarized as follows; 1. Fuji Fil LC released the highest amount of fluoride, followed by Fuji II LC and $Ketac^{TM}$ N 100(p<0.05). 2. The compressive strength of Fuji Fil LC was the lowest(p<0.05). However, no significant difference was found from Fuji II LC and $Ketac^{TM}$ N 100(p>0.05). By considering the above results, careful case selection and accurate clinical application is recommended when using $Ketac^{TM}$ N 100 and Fuji Fil LC.

  • PDF

PROPERTIES OF LIGHT-CURED COMPOSITE RESINS CONTAINING $SrF_2$, GLASS FILLER ($SrF_2$계 충진재를 함유한 광중합형 복합레진의 특성)

  • Kim, Hee-Jung;Kim, Kyung-Nam;Choi, Byung-Jai;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.54-66
    • /
    • 2001
  • The aim of this study was to investigate the fluoride release and some mechanical properties including 3-point bending strength, amount of abrasion, surface hardness, water sorption/solubility and cytotoxicity of the newly developed composite resins containing 8, 16, 24 wt% $SrF_2$ glass filler (VF8, VF16, VF24) and four commercially available composite resins, Heliomolar(HE), Verdonfil(VE), Z100(ZH) and Aelitefil(AE). To investigate cytotoxic effect, agar overlay assay was done. Amount of fluoride released into distilled water was measured over a 62-days period from VF8, VF16, VF24 and HE. Results were as follows: 1. Experimental composite resins showed similar mechanical properties to commercial composite resins, but 3-point bending strength and surface hardness of experimental composite resins were inferior to ZH. 2. Over a 62-day Period, the amount of fluoride released was ordered: VF24>VF16>VF8>HE. In experimental composite resins, the amount of fluoride released was 9-23 times greater than HE and seemed to be proportional to the content of $SrF_2$ glass filler. 3. Experimental composite resins and all control composite resins showed mild cytotoxicity. This study showed significantly greater fluoride release from newly developed composite resins than control(HE) and addition of $SrF_2$ glass filler did not decrease mechanical properties or increase cytotoxicity of composite resin. The results from this study imply that newly developed composite resin have adequate mechanical properites, mild cytotoxicity and some potential for secondary caries prevention.

  • PDF

CHANGES IN ADHESION OF STREPTOCOCCUS MUTANS TO NANOCOMPOSITE RESINS AFTER ACIDULATED PHOSPHATE FLUORIDE GEL APPLICATION (나노컴포지트에서 Acidulated Phosphate Fluoride 적용에 따른 Streptococcus mutans 부착량 변화)

  • Jung, Young-Jung;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.427-436
    • /
    • 2005
  • Topical application of APF gel can increase the surface roughness of resin composites and the roughened surfaces may allow increased bacterial accumulation and surface staining. Resin specimens of two proprietary resin composites, Filtek Z250(FZ) and Filtek Supreme Universal(FS), and experimental resin composites containing 0%, 3%, 6% nanofillers(E0, E3, E6) were fabricated and divided into two groups of the same number; APF treatment group and no treatment group. The amount of S. mutans adhered to specimens and the mean surface roughness(Ra) were measured. The results were as follows; 1. In no treatment group, the amount of S. mutans adhered to FS was the smallest. It was significantly different from those of FZ, E3, E6(p<0.05) although it was not significantly different from that of E0(p>0.05). 2. For all resin composites used, the amount of S. mutans adhesion in APF treatment group was significantly greater than that in no treatment group(p<0.05). 3. In APF treatment group, the amount of S. mutans adhesion was significantly different between materials(p<0.05), and increased in order of FS, FZ, E0, E3 and E6. 4. Difference of the surface roughness(Ra) between materials was not statistically significant in both no treatment group and APF treatment group(p>0.05)

  • PDF

Effect of hydrofluoric acid-based etchant at an elevated temperature on the bond strength and surface topography of Y-TZP ceramics

  • Yu, Mi-Kyung;Lim, Myung-Jin;Na, Noo-Ri;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.1
    • /
    • pp.6.1-6.8
    • /
    • 2020
  • Objectives: This study investigated the effects of a hydrofluoric acid (HA; solution of hydrogen fluoride [HF] in water)-based smart etching (SE) solution at an elevated temperature on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramics in terms of bond strength and morphological changes. Materials and Methods: Eighty sintered Y-TZP specimens were prepared for shear bond strength (SBS) testing. The bonding surface of the Y-TZP specimens was treated with 37% phosphoric acid etching at 20℃-25℃, 4% HA etching at 20℃-25℃, or HA-based SE at 70℃-80℃. In all groups, zirconia primers were applied to the bonding surface of Y-TZP. For each group, 2 types of resin cement (with or without methacryloyloxydecyl dihydrogen phosphate [MDP]) were used. SBS testing was performed. Topographic changes of the etched Y-TZP surface were analyzed using scanning electron microscopy and atomic force microscopy. The results were analyzed and compared using 2-way analysis of variance. Results: Regardless of the type of resin cement, the highest bond strength was measured in the SE group, with significant differences compared to the other groups (p < 0.05). In all groups, MDP-containing resin cement yielded significantly higher bond strength values than MDP-free resin cement (p < 0.05). It was also shown that the Y-TZP surface was etched by the SE solution, causing a large change in the surface topography. Conclusions: Bond strength significantly improved when a heated HA-based SE solution was applied to the Y-TZP surface, and the etched Y-TZP surface was more irregular and had higher surface roughness.

Nanotube Morphology Change of Ti-Ta-Zr Alloy as Zr Content

  • Kim, Won-Gi;Choe, Han-Cheol;Ko, Yeong-Mu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.105-106
    • /
    • 2008
  • Nanotube morphology change of Ti-Ta-Zr alloy as Zr content increase has been researched using various experimental methods. Ti-Ta-Zr(3, 7 and 15 wt%) alloys were prepared by arc melting and nano-structure controlled for 24 hr at $1000^{\circ}C$ in argon atmosphere. Formation of oxide nanotubes are conducted by anodizing a Ti-Ta-Zr alloy in $H_3PO_4$ electrolytes with small amounts of fluoride ions at room temperature. Electrochemical experiments were carried out with conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. The samples were embedded with epoxy resin, leaving a square surface area of $10mm^2$ exposed to the anodizing electrolyte, 1.0M $H_3PO_4$ containing 0.8wt% NaF.

  • PDF

Clinical Effect of MS Coat and Elmex gel on the Dentin Hypersensitivity following Periodontal Surgery (치주수술 후 지각과민증에 대한 MS Coat와 엘멕스 겔처치의 임상적 효과)

  • Park, Sung-Min;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.727-736
    • /
    • 2001
  • Dentinal hypersensitivity is one of the complicated symptom rather than a disease. It has special reaction or pain over uncovered root by heat, mechanical or chemical stimulations, which are normal with healthy teeth, The purpose of this study is to discover rather MS Coat (oxalate-containing pre-polymerized resin suspension) or Elmex gel(amine fluoride+sodium fluoride) is effective on hypersensitivity after periodontal treatment using NRS(Numerica1 Rating Scales), which it is useful for evaluating pain level. This study has been prepared in Dankook Dental Hospital with generally healthy adult who had been suffered from dentinal hypersensitivity after periodontal treatment. Divided in three groups with saline(control group), MS Coat(test 1 group) and Elmex gel(test 2 group). And then, following evaluations were made at the end of 1 minute, 1 week, 1 month and 3 months. 1. The sequence of higher frequency & severeness of hypersensitivity is water within $7^{\circ}C$, air stream & explorer. 2. As time goes on, 1 minute, 1 week, 1 month & 3 months, severeness of hypersensitivity scored lower with water, air stream and explorer. 3. With explorer, the differences among three groups as time had to seen. 4. With air stream, the sensitivity scored lower after 1min with MS Coat, Elmex, and saline sequence. As time goes on the sensitivity was lower with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. 5. With water in $7^{\circ}C$, the sensitivity was much decreasing with MS Coat and Elmex than saline, but there was no difference between MS Coat and Elmex. As the result, MS Coat and Elmex are effective on hypersensitivity caused by periodontal treatment.

  • PDF

Microleakage and Anticariogenic Effect of S-PRG Filler-containing Pit and Fissure Sealant (S-PRG filler를 함유한 치면열구전색제의 미세누출 및 항우식효과)

  • Shin, Seungwoo;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Pit and fissure sealant prevents biofilm accumulation, plays a role in forming a barrier to acidic substance made by the bacteria. The Surface reaction-type pre-reacted glass ionomerI(S-PRG) filler was developed in 1999. S-PRG filler releases fluoride continuously and does not decompose under wet conditions. The aim of this study was to test the microleakage and anticariogenic effect to adjacent enamel of S-PRG filler-containing pit and fissure sealant. Sound premolars and molars were used in this study. A S-PRG filler-containing pit and fissure sealant, Beautisealant$^{(R)}$(Shofu, Japan) was used for this experiment, the composite resin sealant Concise$^{(R)}$(3M ESPE, USA) was used as control. For the microleakage test, all teeth surface were double coated with finger nail varnish, with the exception of a 1.0 mm window around the restoration margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in tap water. For the anticariogenic effect evaluation, all tooth were immersed in artificial carious solution for 9 days and rinsed with tap water. Each tooth was embedded in orthodontic acrylic rein and subsequently sectioned longitudinally in a bucco-lingual direction with a low-speed diamond saw. The cut sections were examined using a stereomicroscope. Differences in microleakage between the two groups were not different significantly. But the S-PRG filler-containing pit and fissure sealant showed higher anticariogenic effect than that of flowable resin sealant.

A STUDY ON THE EVALUATION OF POLYMERIZATION SHRINKAGE OF COMPOSITE AND COMPOMER USING STRAIN GAUGE METHOD (스트레인 게이지법을 이용한 복합레진과 컴포머의 중합수축 평가에 관한 연구)

  • Kim, Yeun-Chul;Kim, Jong-Soo;Kwon, Soon-Won;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.19-29
    • /
    • 2002
  • The purpose of this study was to compare the polymerization shrinkage and the compressive strength of composite and compomer cured with two different light sources ; conventional halogen-light curing unit and recently-developed plasma arc curing unit. The 'strain gauge method' was used for determination of polymerization shrinkage and the compressive strength was measured by universal testing machine. The results of the present study can be summarized as follows: 1. Filling materials in polyethylene molds showed the initial expansion in the early phase of polymerization. This was followed by the rapid contraction in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The polymerization shrinkage in tooth samples was generally lower than in the mold samples. 3. The generally lower amount of linear polymerization shrinkage was observed in compomer and plasma arc curing unit group when compared to composite and conventional curing unit. 4. The higher compressive strength values was found in composite groups regardless curing methods. The results of this study strongly support the application of plasma arc system and fluoride-containing compomer in the field of clinical pediatric dentistry claiming its effectiveness in curing the esthetic dental materials and the anticariogenic capacity.

  • PDF