• Title/Summary/Keyword: fluorescence index

Search Result 142, Processing Time 0.023 seconds

Application of a solid-phase fluorescence immunoassay to determine streptomycin residues in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major)

  • Chung, Hee Sik;Kim, Suk;Chun, Myung Sun;Jung, Won Chul;Kim, Dong Hyeok;Shon, Ho Yeong;Lim, Jeong Ju;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.241-245
    • /
    • 2007
  • Parallux (IDEXX Laboratories, USA), a solid-phase fluorescence immunoassay (SPFIA) developed for antibiotics residue detection in milk, was applied for analysis of antibiotics in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major). Fishes were dipped in streptomycin 20 g/ton water, the recommended therapeutic dose, for 3 consecutive days. Muscle was sampled after 1st, 2nd, 3rd, 4th and 5th day drug treatment. The concentration of streptomycin in muscle, determined by SPFIA, was compared with that of internal standard (200 ppb as streptomycin). The absorbance ratio of sample to internal standard (S/C) was employed as an index to determine the muscle residues in fishes. The standard solutions were added to muscle samples to give final concentrations in muscle of 0.2 and 0.5 mg/ml to investigate the recovery rate. The recovery rates of all spiked samples were > 84% of the spiked value. Streptomycin was detected in muscles of fishes treated after the 1st day of withdrawal period. The present study showed that the SPFIA can be easily adopted in predicting muscle tissue residues for streptomycin in farmed fishes.

Spectroscopic Properties of Er-doped Sulfide Fiber (Er 첨가 황화물계 광섬유의 제조 및 분광학적 특성)

  • Choi, Yong-Gyu;Lim, Dong-Sung;Kim, Kyong-Hon;Park, Se-Ho;Heo, Jong
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.8
    • /
    • pp.781-786
    • /
    • 2000
  • An Er-doped sulfide fiber was drawn, and its spectroscopic properties were analyzed. Compositions of a 1000 ppmwt Er3+-doped core and an undoped clad were Ge30-Ga1-Asg-S61 and Ge30-As8-S62, in at.%, respectively. Refractive index of the core composition was approximately 0.01 high than that of the clad. In order to enhance the mechanical stability as well as to prevent infiltration of impurity ions such as OH-, an UV-curable polymer was used for the coating. The optical loss of a fiber formed directly from a polymer coated core rod without cladding was ∼15 dB/m at 1.06$\mu\textrm{m}$. In the case of a fiber with core/clad structure, the optical loss was so high that the stimulated emission of erbium fluorescence was not evident. It is believed that presence of inhomogeneous core/clad interface and crystalline aggregates precipitated in the clad region were responsible for the high optical loss. On the other hand, fluorescence characteristics of Er3+ embedded in the core region were more or loss deteriorate compared to fiber preform, which is attributed to the redistribution of the Er ions along with the partial crystallization of the core glass during the fiberization process.

  • PDF

Dynamics of Microalgae Along the Coastal Areas of Sooyoung Bay, Busan, South Korea

  • Prasad, Binod;Thiyam, General;Lee, Dong-Gyu;Kim, Moo-Sang;Cho, Man-Gi
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.5 no.4
    • /
    • pp.40-45
    • /
    • 2011
  • Microalgae are one of the major, sustaining components of ecosystem processes and are responsible for biogeochemical reactions that drive our climate changes. Despite this, many marine microalgae are poorly described and little is known of their abundance and distribution along the coastal areas of Sooyoung Bay, Busan, South Korea. The present study has been conducted from November, 2011 to August, 2009 with the objective to provide an overview of the taxonomy diversity and abundance of microalgae along the coastal areas of the Sooyoung Bay. Water samples were collected from different sites, which were located by using a GPS tracker. Chlorophyll fluorescence of the water samples were measured by using ToxY-PAM dual-channel yield analyzer. The chlorophyll fluorescence values were relatively higher during the spring and summer and even in the region near to the sea port. Similarly the abundance of microalgae was higher near the port but diversity index had lower values. The temperature and pH values were same at all the sites. However, only the temperature varied during the sampling period, with higher values during summer and lower in winter. From the preliminary results, the following class of microalgae were found; Bacillariophyceae, Dinophyceae, Silicoflagellate and Cryptophyceae. With a future ongoing work, microalgae are being isolated to establish single cell culture and for identification using light microscopic observations, photography and molecular approaches.

Estimating the Relative Contribution of Organic Phosphorus to Organic Matters with Various Sources Flowing into a Reservoir Via Fluorescence Spectroscopy (형광스펙트럼을 이용한 유역 하류 저수지의 유입 유기물 내 유기인 기여도 평가)

  • Mi-Hee Lee;Seungyoon Lee;Jin Hur
    • Journal of Korean Society on Water Environment
    • /
    • v.40 no.2
    • /
    • pp.67-78
    • /
    • 2024
  • The introduction of a significant amount of phosphorous into aquatic environments can lead to eutrophication, which can in turn result in algal blooms. For the effective management of watersheds and the prevention of water quality problems related to nonpoint organic matter (OM) sources, it is essential to pinpoint the predominant OM sources. Several potential OM sources were sampled from upper agricultural watersheds, such as fallen leaves, riparian reeds, riparian plants, paddy soil, field soil, riparian soil, cow manure, and swine manure. Stream samples were collected during two storm events, and the concentrations of dissolved organic carbon (DOC) and phosphorous (DOP) from these OM sources and stream samples were assessed. DOM indicators using fluorescence spectroscopy, including HIX, FI, BIX, and EEM-PARAFAC, were evaluated in terms of their relevance in discerning DOM sources during storm events. Representative DOM descriptors were chosen based on specific criteria, such as value ranges and pronounced differences between low and high-flow periods. Consequently, the spectral slope ratio (SR) paired with fluorescence index (FI) using end-member mixing analysis (EMMA) proved to be suitable for estimating the contribution of organic carbon (OC). The contribution of each organic phosphorous (OP) in stream samples was determined using the phosphorous-to-carbon (P/C) ratio in conjunction with the OC contribution. Notably, OP derived from swine manure in stream samples was found to make the most dominant contribution, ranging from 61.3% to 94.2% (average 78.1% ± 12.7%). The results of this research offer valuable insights into the selection of suitable indicators to recognize various OM sources and highlight the main sources of OP in forested-agricultural watersheds.

Prediction of Coagulation/Flocculation Treatment Efficiency of Dissolved Organic Matter (DOM) Using Multiple DOM Characteristics (다중 유기물 특성 지표를 활용한 용존 유기물질 응집/침전 제거효율 예측)

  • Bo Young Kim;Ka-Young Jung;Jin Hur
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.465-474
    • /
    • 2023
  • The chemical composition and molecular weight characteristics of dissolved organic matter (DOM) exert a profound influence on the efficiency of organic matter removal in water treatment systems, acting as efficiency predictive indicators. This research evaluated the primary chemical and molecular weight properties of DOM derived from diverse sources, including rivers, lakes, and biomasses, and assessed their relationship with the efficiency of coagulation/flocculation treatments. Dissolved organic carbon (DOC) removal efficiency through coagulation/flocculation exhibited significant correlations with DOM's hydrophobic distribution, the ratio of humic-like to protein-like fluorescence, and the molecular weight associated with humic substances (HS). These findings suggest that the DOC removal rate in coagulation/flocculation processes is enhanced by a higher presence of HS in DOM, an increased influence of externally sourced DOM, and more presence of high molecular weight compounds. The results of this study further posit that the efficacy of water treatment processes can be more accurately predicted when considering multiple DOM characteristics rather than relying on a singular trait. Based on major results from this study, a predictive model for DOC removal efficiency by coagulation/flocculation was formulated as: 24.3 - 7.83 × (fluorescence index) + 0.089 × (hydrophilic distribution) + 0.102 × (HS molecular weight). This proposed model, coupled with supplementary monitoring of influent organic matter, has the potential to enhance the design and predictive accuracy for coagulation/flocculation treatments targeting DOC removal in future applications.

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.

Bleaching Observation of Cosmetic Color Lenses According to Multipurpose Contact Lens Solutions (다목적 콘택트렌즈 용액에 대한 미용 칼라렌즈의 탈색 관찰)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.295-303
    • /
    • 2014
  • Purpose: This study aims to observe bleaching resulted from multipurpose contact lens solutions used to manage lenses with the subjects of colored contact lenses being distributed in Korea. Methods: The lenses have been worn for six months, and their refraction is 0.00D. Three types of colored contact lenses of which margin has been colored with a different manufacturing method have been adopted (type 1: pigment application method, type 2: chemical bonding process, type 3: sandwich method), and multipurpose solutions used were two types containing different components. Each of the colored contact lenses was stored in the multipurpose solutions for 20 days and went through vortexing for 15 seconds per day. Their fluorescence absorbance, surface roughness, brightness index, and color coordinate index were measured before and after the vortexing to see the degree of bleaching. Results: In the two types of multipurpose solutions, every type of the color contact lenses showed no statistically significant difference in their fluorescence absorbance value before and after the vortexing. Regarding surface image, the front surface of the lenses was smooth in every type, and about the back surface, type 3 indicated less protrusion than type 1 and 2. About the difference of color on the lens surface before and after the vortexing, type 3 showed significantly less difference than type 1 and 2; however, all fell into the permissible error. Conclusions: About the bleaching of colored contact lenses resulted from multipurpose solutions for soft contact lenses, there was no difference observed in terms of fluorescence absorbance and color. According to the methods of manufacturing dyes, however, there was difference in the protrusion of the posterior surface image.

Characteristics of Microbial Distribution of Nitrifiers and Nitrogen Removal in Membrane Bioreactor by Fluorescence in situ Hybridization (막/생물반응기에서 Fluorescence in situ Hybridization 기법을 이용한 질산화 미생물 분포특성 및 질소제거 연구)

  • Lim Kyoung-Jo;Kim Sun-Hee;Kim Dong-Jin;Cha Gi-Cheol;Yoo Ik-Keun
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.3
    • /
    • pp.257-264
    • /
    • 2006
  • An aerobic submerged membrane bioreactor (MBR) treating ammonium wastewater was studied in respect of nitrification characteristics and distribution of nitrification bacteria over a period of 350 days. MBR was fed with ammonium concentration of 500-1000 mg $NH_4-N/L$ at a nitrogen load of $1-2kg\;N/m^3{\cdot}d$. Overall ammonium oxidation rate increased with dissolved oxygen (DO) concentration, temperature, and sludge retention time (SRT). Under a higher concentration of free ammonia ($NH_3-N$) due to the decrease of ammonium oxidation rate, the nitrite ratio ($NO_2-N/NO_x-N$) in the effluent increased. The sudden collapse of nitrification efficiency accompanied by sludge foaming and the increase of sludge volume index (SVI) was observed unexpectedly during the operation. At the later stage of operation, additional carbon source was fed to the MBR and resulted in twice higher value of SVI and the decrease of ammonium oxidation rate. In fluorescence in situ hybridization (FISH) analysis, genus Nitrosomonas which is specifically hybridized with probe NSM156 was initially the dominant ammonia oxidizing bacteria and the amount of Nitrosospira gradually increased. Nitrospira was the dominant nitrite oxidizing bacteria during whole operational period. Significant amount of Nitrobacter was also detected which might due to the high concentration of nitrite maintained in the reactor.

An Effects of a New PGE1: Lipo-AS013 on Blood Flow and Survival of Skin Flap (새로운 PGE1인 Lipo-AS013이 피판의 혈류와 생존에 미치는 영향)

  • Seul, Chul Hwan;Choi, Jong Woo;Chi, Yong Hoon;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.5-11
    • /
    • 2005
  • Prostaglandin $E_1$($PGE_1$) is known to have various physiological action such as vasodilatation, decrease of blood pressure, angiogenesis, inhibition of platelet aggregation and so forth. $PGE_1$ has been developed in many different formulations in order to overcome its chemical instability and deactivation in the lungs when administered parenterally. Lipo-AS013 is a potent drug with higher chemical stability and greater vascular wall targeting than others. The study was done on $3{\times}10cm$ model flap of dorsal skin of Sprague-Dawley rats and the flap perfusion survival were observed and documented. The flap treated with Lipo-AS013 beforehand was given intravenously Sodium fluorescein 10 minutes later, and then Percent Dye Fluorescence Index(% DFI) was calculated. The results were compared to a control group and the group administered locally epinephrine.. In the control group, the % DFI and flap survival rate increased from $54.1{\pm}6.7$ to $65.0{\pm}2.6$(p<0.01) while in Lipo-AS013 group from $55.3{\pm}2.2$ to $67.4{\pm}1.9$(p<0.01), respectively. In the epinephrine group, the % DFI(p<0.05) and flap survival rate(p<0.001) decreased. In the both epinephrine and Lipo-AS013 group Percent DFI and flap survival rate are comparable with the control group.The result indicates that the potent Lipo-AS013 enhances the blood flow and flap survival. This highly potent Lipo-AS013 may have targeting ability and accumulate $PGE_1$ onto the vascular walls. A quantitative analysis of fluorescence on the skin surface is a reliable tool to measure the blood perfusion into an ischemic flap and its viability. Further comparative study with conventional $PGE_1$ and Lipo-$PGE_1$ is needed in order to clarify the action and efficiency of Lipo-AS013.

A simple colorimetric method for the clinical evaluation of caries activity in adults (성인의 치면세균막 내 산생성능력과 치아우식경험과의 연관성)

  • Kim, Hyo-Jung;Ku, Hye-Min;Lee, Eun-Song;Kwon, Ho-Keun;Kim, Baek-Il
    • The Journal of the Korean dental association
    • /
    • v.55 no.6
    • /
    • pp.413-422
    • /
    • 2017
  • Purpose: The aim of this study was to confirm the validity of the $Cariview^{TM}$, test in adults by assessing correlations between $Cariview^{TM}$, scores and caries experience using a quantitative light-induced fluorescence (QLF) technique. Methods: This retrospective cross-sectional study included 111 patients aged 19-64 years who visited a dental clinic in Seoul from 2015 to 2016, and underwent the $Cariview^{TM}$, test and had their teeth photographed with the Qraycam. Plaque was scraped with sterilized cotton swabs, and then placed in a culture medium and incubated at $37^{\circ}C$ for 48 h. Finally, the degree of color change was evaluated, and scored on a 0-100 point scale. Caries experience index included not only cavitated lesions but also early caries that were detected on white and fluorescence images. Participants were divided into low, moderate and high caries risk groups according to the $Cariview^{TM}$, score, and caries experience was compared between risk groups using ANCOVA. Spearman correlation coefficients were calculated to analyze the associations between $Cariview^{TM}$, scores and caries indices. Result: The mean age of the participants was 40 years, and the mean $Cariview^{TM}$, score was $53.6{\pm}20.7$. The WDMFT and the DMFT indices significantly increased with caries risk, and this increase was significantly different between the low- and high-risk groups. The $Cariview^{TM}$, test scores were significantly correlated with the WDMFT (r = 0.28, P = 0.003) and DMFT (r = 0.29, P = 0.002) indices. Conclusion: The $Cariview^{TM}$, test could be a clinically useful and simple method for assessing caries risk in adults.

  • PDF