• Title/Summary/Keyword: fluorescence index

Search Result 142, Processing Time 0.03 seconds

Study on the Factors Influencing the Fluorescence Index of Internal Fluorescent Whitening Agent (내첨 형광증백제의 형광현상에 영향하는 인자에 대한 연구)

  • Lim, Gi-Baek;Lee, Ji-Young;Kim, Chul-Hwan;Kim, Sun-Young;Park, Jong-Hea
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.1
    • /
    • pp.11-17
    • /
    • 2014
  • This study analyzed the effects of specific factors on the fluorescence index of the fluorescent whitening agent (FWA) that is used for internal addition. The specific factors were identified by the literature review, and a statistical survey was carried out to analyze the effects of those factors on the fluorescence index. Bulk, grammage, fillers and internal sizing agents were selected as the specific factors. The paper samples were prepared with internal FWA in a laboratory. The fluorescence indices of the model papers were measured, and p-values of the specific factors on the fluorescence index were calculated by the SPSS program. Most of p-values were greater than 0.05, so the specific factors do not have a significant impact on the internal FWA fluorescence index.

Fundamental Study on the Quantitative Analysis of Fluorescent Whitening Agent used for Papermaking (제지용 형광증백제의 정량분석에 대한 기초연구)

  • Lee, Ji-Young;Kim, Chul-Hwan;Lee, Hui-Jin;Gwak, Hye-Joeng
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.2
    • /
    • pp.9-15
    • /
    • 2011
  • Fluorescent whitening agent (FWA) is a widely used chemical in paper industry, but a systematic and scientific method on FWA analysis has not been established. We performed the basic researches on the fluorescence analysis of FWA. The fluorescence of FWA was investigated using a spectrofluorometer and a spectrophotometer. When FWA solution was analyzed using the spectrofluorometer, we found that the peak wavelength of the fluorescence emission was about 440 nm and that of the fluorescence excitation was about 370 nm irrespective of FWA types. Papers dyed with an internal FWA were prepared in a laboratory and the reflectance and the fluorescence index were measured using the spectrophotometer. It was confirmed that the optimum peak wavelength of the reflectance was 440 nm and the fluorescence index calculated from the CIE whiteness with and without UV light under a light source D65 was the best indicator to measure the fluorescence of FWAs exiting in papers.

Study on the Detachment of Fluorescent Whitening Agents from White Waster Papers (인쇄용지 재활용을 위한 형광증백제 탈착에 대한 기초연구)

  • Lee, Ji Young;Kim, Chul Hwan;Kim, Eun Hea;Park, Tae Ung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.2
    • /
    • pp.5-12
    • /
    • 2016
  • White waste papers are very important resources in the paper industry, but their use is limited because of the residual of fluorescent whitening agent (FWA). So the removal of FWAs from waste paper is an important task in the recycling process to improve the use of recycled resources. In this study, we focused on the FWAs used for surface treatments and carried out physical and chemical treatments to remove them from white waste papers. The white waste papers were disintegrated with a surfactant in different pH and temperature conditions, and then handsheets were made for the measurement of the fluorescence index, which is proportional to the amount of FWAs on papers. The effect of the flotation process on the removal of FWAs after disintegration was also investigated. The fluorescence index decreased as the disintegration time increased, but over a relatively long time, the fluorescence index increased again, which indicated the readsorption of the FWAs detached from the cellulosic fibers of the white waste papers. The lowest fluorescence index was shown when the waste papers were disintegrated with a 0.3% surfactant addition at pH 10 and at $45^{\circ}C$. However, the flotation treatment was not effective, because the flotation induced contact between the detached FWAs and the cellulosic fibers, and re-adsorption occurred.

Study on the Thermal Fastness of Fluorescent Whitening Agents (제지용 형광증백제의 열 견뢰도에 대한 연구)

  • Kim, Chul-Hwan;Lee, Ji-Young;Kim, Beong-Ho;Choi, Jae-Sung;Lim, Gi-Baek;Kim, Da-Mi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Fluorescent whitening agents (FWAs) are used extensively in the paper industry to improve the optical properties. FWAs are neither photochemically nor thermally stable, and thereby the papers containing FWAs can be damaged by external heat. We observed that the CIE whiteness, ISO brightness and fluorescence index of the commercial papers decreased with the thermal treatment and thought that the thermal fastness of FWAs was the main factor affecting the thermal stability of the papers. Thus, the model papers treated with three types of FWAs were manufactured respectively and the thermal stability of FWAs was identified by determining ${\Delta}$ CIE whiteness and ${\Delta}$ fluorescence index.

Design of Optical Biological Sensor for Phycocyanin Parameters Measurement using Fluorescence Technique

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Ann, Myungsuk;Yang, Seungyoun
    • International journal of advanced smart convergence
    • /
    • v.5 no.2
    • /
    • pp.73-79
    • /
    • 2016
  • Remote sensing and measurement are of paramount importance of providing information on the state of water quality in water bodies. The formation and growth of cyanobacteria is of serious concern to in land aquatic life forms and human life. The main cause of water quality deterioration stems from anthropogenic induced eutrophication. The goal of this research to quantify and determine the spatial distribution of cyanobacteria concentration in the water using remote sensing technique. The standard approach to measure water quality based on the direct measurement of the fluorescence of the chlorophyll a in the living algal cells and the same approach used to detect the phycobilin pigments found in blue-green algae (a.k.a. cyanobacteria), phycocyanin and phycoerythrin. This paper propose the emerging sensor design to measure the water quality based on the optical analysis by fluorescence of the phycocyanin pigment. In this research, we developed an method to sense and quantify to derive phycocyanin intensity index for estimating cyanobacteria concentrations. The development of the index was based on the reflectance difference between visible light band 620nm and 665nm. As a result of research this paper presents, an optical biological sensor design information to measure the Phycocyanin parameters in water content.

Predictation of the Concentrations and Distributions of Refractory Organic Matters in Wastewater using Spectroscopic Characteristics (분광특성을 이용한 하·폐수시료 내 난분해성 유기물 농도 및 분포 예측)

  • Lee, Bomi;Park, Min-Hye;Lee, Tae-Hwan;Hur, Jin;Yang, Heejung
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.560-567
    • /
    • 2009
  • Treated or untreated wastewater may be a major source of refractory organic matters (R-OM) in drinking water sources. For this study, spectroscopic characteristics of wastewater OM were investigated using the samples from 20 wastewater treatment plants, which are located at the upstream of the lake Paldang, to suggest a estimate index for R-OM in wastewater. R-OM was quantified by measuring total organic carbon (TOC) concentration of the wastewater samples remaining after 28-day dark incubation. Among the traditional OM indices such as chemical oxygen demand (COD) and initial TOC, CODMn showed the lowest correlation coefficients with R-TOC of the samples. The ratios of carbonaceous biochemical oxygen demand (CBOD) to $COD_{Cr}$ had a better correlation with the percent distribution of R-OM than $BOD/COD_{Cr}$ ratios. terrestrial humic-like fluorescence (THLF) exhibited the highest correlation coefficient with R-TOC among the indices obtained from the synchronous fluorescence spectra of the samples. Milori index, one of the humification indices, showed a good correlation with the percent distribution of wastewater. This study demonstrated that fluorescence properties might be a better indices to estimate the concentrations and the distributions of wastewater OM compared to the specific UV absorbance (SUVA) values. Some useful formulas based on OM spectroscopic characteristics were finally suggested to predict R-OM in wastewater.

Monitoring of Water Quality Parameters using Spectroscopic Characteristics of River Water - Ulsan Area (하천 분광특성을 이용한 수질항목 모니터링 연구 - 울산 지역)

  • Hur, Jin;Kim, Mi-Kyung;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.863-871
    • /
    • 2007
  • Spectroscopic characteristics of river water from four major watersheds in the Ulsan area were measured to examine their potential for estimating water quality parameters. The total 176 river samples were collected from 44 sites of small streams within the watersheds during the year 2006. Spectroscopic characteristics investigated included protein-like fluorescence (FLF) intensity, fulvic-like fluorescence (FLF) intensity, terrestrial humic-like fluorescence (TLF) intensity, UV absorbance at 254 nm, and UV absorbance difference at 220 nm and 254 nm. Protein-like fluorescence intensity showed linear relationships with biochemical oxygen demand (BOD), chemical oxygen demand (COD), total phosphorous (TP) concentrations of the samples with the correlation of 0.784, 0.779, and 0.733, respectively. Due to the UV absorption characteristics of nitrate at 220 nm, UV absorbance difference at 220 nm and 254 nm was selected to represent total nitrogen (TN) concentration. Exclusion of some samples with PLF intensity higher than 5.0 improved the correlation between the UV absorbance difference and TN as demonstrated by the increase of the correlation coefficient from 0.392 to 0.784. Instead, for the samples with PLF intensity lower than 5.0, the highest correlation of TN was achieved with UV absorbance at 254 nm. The results suggest that PLF intensity could be used as the estimation index for BOD, COD, and TP concentration of river water, and as the primary screening index for the prediction of TN using UV absorbance difference. Some BOD-based water quality levels among the river water were statistically discriminated by the PLF intensity. Low p-values were obtained from the t-tests on the samples with the first level and the second level (p=0.0003) and the samples with the second and the third levels (p=0.0413). Our combined results demonstrated that the selected spectroscopic characteristics of river water could be utilized as a tool for on-site real-time monitoring and/or the primary estimation of water quality.

Evaluation of fingerprints enhanced fluorescent using contrast index (Contrast Index를 이용한 형광지문 증강 정도의 수치적 판단)

  • Jeon, Soyoung;Ki, Jinyoung;Kim, Kyuyeon;Kim, Jiyeon;Kim, Chaewon;Yu, Jeseol
    • Analytical Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.195-200
    • /
    • 2018
  • Researchers have used the visual criteria to compare the effectiveness of fingerprint enhancement techniques. However, since the visual criteria is subjective, bias can occur. Therefore, many researchers have tried to make the criteria objective using the contrast index (CI). However, there is a constraint that the CI was only validated on inked fingerprints or color-change fingerprints. In this study, we compared enhancement of fluorescence fingerprints on colored papers using the CI. The CI values differ according to the color of the background, reagent, and light source, even though the same standard fingerprints were used. Through the comparison of values, we could compare the enhancement of fluorescence fingerprints according to these factors. When visual evaluation criteria were used, the same peak score was obtained regardless of the reagent and light source. However, we could get a more detailed score comparison in this study using the CI. Therefore, it is confirmed that for comparison of enhancement of fluorescence fingerprints, the CI can be used as a basis for determining which light source and reagent are appropriate according to the background.

Comparison of Clinical Characteristics of Fluorescence in Quantitative Light-Induced Fluorescence Images according to the Maturation Level of Dental Plaque

  • Jung, Eun-Ha;Oh, Hye-Young
    • Journal of dental hygiene science
    • /
    • v.21 no.4
    • /
    • pp.219-226
    • /
    • 2021
  • Background: Proper detection and management of dental plaque are essential for individual oral health. We aimed to evaluate the maturation level of dental plaque using a two-tone disclosing agent and to compare it with the fluorescence of dental plaque on the quantitative light-induced fluorescence (QLF) image to obtain primary data for the development of a new dental plaque scoring system. Methods: Twenty-eight subjects who consented to participate after understanding the purpose of the study were screened. The images of the anterior teeth were obtained using the QLF device. Subsequently, dental plaque was stained with a two-tone disclosing solution and a photograph was obtained with a digital single-lens reflex (DSLR) camera. The staining scores were assigned as follows: 0 for no staining, 1 for pink staining, and 2 for blue staining. The marked points on the DSLR images were selected for RGB color analysis. The relationship between dental plaque maturation and the red/green (R/G) ratio was evaluated using Spearman's rank correlation. Additionally, different red fluorescence values according to dental plaque accumulation were assessed using one-way analysis of variance followed by Scheffe's post-hoc test to identify statistically significant differences between the groups. Results: A comparison of the intensity of red fluorescence according to the maturation of the two-tone stained dental plaque confirmed that R/G ratio was higher in the QLF images with dental plaque maturation (p<0.001). Correlation analysis between the stained dental plaque and the red fluorescence intensity in the QLF image confirmed an excellent positive correlation (p<0.001). Conclusion: A new plaque scoring system can be developed based on the results of the present study. In addition, these study results may also help in dental plaque management in the clinical setting.

Prediction of Trihalomethanes Formation Potential of Dissolved Organic Matter with Various Sources Using Differential Fluorescence 3D-Excitation-Emission Matrix (EEM) (차등 3차원 형광 여기-방출 매트릭스를 이용한 다양한 기원의 용존 유기물질 트리할로메탄 생성능 예측)

  • Bae, Kyung Rok;Hur, Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.2
    • /
    • pp.63-71
    • /
    • 2022
  • This study aimed to maximize the potential of fluorescence 3D excitation-emission matrix (EEM) for predicting the trihalomethane formation potential (THMFP) of DOM with various sources. Fluorescence spectroscopy is a useful tool for characterizing dissolved organic matter (DOM). In this study, differential spectroscopy was applied to EEM for the prediction of THMFP, in which the difference between the EEM before and after chlorination was taken into account to obtain the differential EEM (DEEM). For characterization of the original EEM or the DEEM, the maximum intensities of several different fluorescence regions in EEM, fluorescence EEM regional integration (FRI), and humification index (HIX) were calculated and used for the surrogates for THMFP prediction. After chlorination, the fluorescence intensity decreased by 77% to 93%. In leaf-derived and effluent DOM, there was a significant decrease in the protein-like peak, while a more pronounced decrease was observed in the humic-like peak of river DOM. In general, leaf-derived and effluent DOM exhibited a relatively lower THMFP than the river DOM. Our results were consistent with the high correlations between humic-like fluorescence and THMFP previously reported. In this study, HIX (r= 0.815, p<0.001), FRI region V (r=0.727, p<0.001), humic-like peak (r= 0.827, p<0.001) from DEEM presented very high correlations with THMF P. When the humic-like peak intensity was converted to a logarithmic scale, a higher correlation was obtained (r= 0.928, p<0.001). This finding suggests that the humic-like peak in DEEM can serve as a universal predictor for THM formation of DOM with various origins.