• 제목/요약/키워드: fluidized bed combustion

검색결과 207건 처리시간 0.027초

Pilot 순환유동층 연소장치에서의 목재펠릿과 아역청탄 혼소 특성 (Characteristics of Co-Combustion of Wood Pellet with Sub-Bituminus Coal in A Pilot CFB Combustor)

  • 김동원;박경일;이종민;배용채
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.436-447
    • /
    • 2019
  • The circulating fluidized bed boiler has an advantage that can burn a variety of fuels from low-grade fuel to coal. In this study, for the design of a circulating fluidized bed boiler using wood pellets, a circulating fluidized bed combustion test device using no external heater was manufactured and used. According to the increase of co-combustion rate with wood pellet, combustion fraction and heat flux by combustor height were measured and pollutant emission characteristics were analyzed. In terms of combustibility, the effect on primary and secondary air ratio were also studied. In addition, as a result of analysis of the effect of corrosive nanoparticles on the combustion of coal with wood pellets, it was confirmed that coal is mostly composed of Ca and S, whereas wood pellets are mostly composed of K, Cl, and Na.

바이오매스 연료의 연소 특성 실험 (A Experiment of Combustion Behavior of Biomass Fuels)

  • 김학덕;김영대;송주헌
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.503-511
    • /
    • 2018
  • There have been many studies of combustion in the circulating fluidized bed. However, little study is available for combustion of wood pellet together fed with wood chip. The mixed ratio of two fuels is an useful information when thermal power company would receive the Renewable Energy Portfolio Standard (RPS) from government. In this study, the combustion behavior and kinetics of such biomass fuels are evaluated using fluidized bed reactor and thermogravimetric analyzers. The mixing ratio of wood chip relative to wood pellet was varied at different temperatures. The results show that a combustion reactivity changed significantly at the wood chip mixing ratio of 40%, particularly at low temperature condition.

유동층연소로에서 유연탄과 무연탄의 연소특성 해석 (Analysis of Combustion Characteristics of Bituminous and Anthracite Coal in a Fluidized Bed Combustor)

  • 장현태;박태성;홍성창
    • 공업화학
    • /
    • 제10권4호
    • /
    • pp.586-591
    • /
    • 1999
  • 유연탄과 무연탄 및 유, 무연탄의 연소특성을 해석하기 위하여 내경 0.109 m의 유동층반응기에서 회분석 석탄주입에 따른 유동화특성과 연소특성 실험을 수행하였다. 온도변화곡선, 압력요동특성치를 이용하여 회분식유동층에서 유연탄과 무연탄 및 혼합석탄의 연소특성을 측정하였다. 유연탄과 무연탄의 입자크기, 두 석탄의 혼합비, 유동화매질의 입자크기에 따른 영향을 고찰하였다. 유연탄과 무연탄의 혼합연소시 무연탄의 혼합비가 30 %인 경우가 유연탄의 연소속도 및 연소거동이 최적으로 나타났다. 저품위 고회분 무연탄의 경우 유동화특성보다 연소특성에 의한 영향이 더욱 크게 나타났다. 또한 유동층의 유동화 특성에 의하여 연소거동이 변화됨을 알 수있었다.

  • PDF

유동상 반응로 조건에서 목재와 RDF 부분 산화의 영향 (Effect of Partial Oxidation of Wood and RDF in a Fluidized Bed)

  • 김태현;최상민
    • 한국연소학회지
    • /
    • 제13권2호
    • /
    • pp.23-32
    • /
    • 2008
  • Gasification characteristics in the fluidized bed reactor are essential for the design of a gasification furnace to optimize the operation condition. Moisture content of the solid fuel is one of the important factors to influence directly the gasification characteristics. So it is necessary to investigate the effect of moisture content of solid fuel in partial oxidation condition. Gasification characteristics are investigated with results from thermogravimetric analyzer and lab-scale fluidized bed reactor for wood and RDF samples along with changing moisture contents. Additionally lab-scale fluidized bed reactor was run continuously and gas concentrations at the exit were measured. It is observed that the rate of reaction in partial oxidation condition is between the results from the combustion environment and from the inert condition. Moisture content in a particle slows down the heating rate of a particle. So, reaction is delayed by the moisture content. However, RDF samples those are easy to break-up don't show the effect of moisture content. The result of continuous operation condition shows that proper moisture content promotes gasification because steam from the particles helps gasification of the solid fuel. A simulation to predict the syn-gas composition was conducted by the Aspen Plus process simulator. The cold gas efficiency of the experiment was compared with results from the simulation.

  • PDF

Self-Cementitious Hydration of Circulating Fluidized Bed Combustion Fly Ash

  • Lee, Seung-Heun;Kim, Guen-Su
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.128-136
    • /
    • 2017
  • Fly ash from a circulating fluidized bed combustion boiler (CFBC fly ash) is very different in mineralogical composition, chemical composition, and morphology from coal ash from traditional pulverized fuel firing because of many differences in their combustion processes. The main minerals of CFBC fly ash are lime and anhydrous gypsum; however, due to the fuel type, the strength development of CFBC fly ash is affected by minor components of active $SiO_2$ and $Al_2O_3$. The initial hydration product of the circulating fluidized bed combustion fly ash (B CFBC ash) using petro coke as a fuel is Portlandite which becomes gypsum after 7 days. Due to the structural features of the portlandite and gypsum, the self-cementitious strength of B CFBC ash was low. While the hydration products of the circulating fluidized bed combustion fly ash (A CFBC ash) using bituminous coal as a fuel were initially portlandite and ettringite, after 7 days the hydration products were gypsum and C-S-H. Due to the structural features of ettringite and C-S-H, A CFBC ash showed a certain degree of self-cementitious strength.

배치형 내부 사이클론식 순환유동층 연소로내 2차 공기 주입에 의한 슬러지 소각 유해 배가스 저감효과 (Effect of Secondary Air Injection on Emission from Sludge Incineration in a Batch-type Internally Cycloned Circulating Fluidized Bed Combustor)

  • 장석돈;신동훈;황정호
    • 한국연소학회지
    • /
    • 제7권3호
    • /
    • pp.16-22
    • /
    • 2002
  • Combustion performance of an internally cycloned circulating fluidized bed for paper sludge was discussed through a series of batch type experiments. Operation parameters such as water content, feeding mass of sludge and secondary air injection rate were varied to find out the effect on the combustion performance, which was examined with carbon conversion rate and pollutant emission such as CO and NOx. A conventional solid fuel reaction was observed in the experiments of varying water content and feeding mass of the sludge, which is characterized with kinetic limited reaction zone, diffusion limited reaction zone and transition zone. Secondary air injection with swirl enhances the mixing of the gas phase as well as the solid phase, and improves combustion efficiency accompanied with higher carbon conversion rate and lower pollutant emission rate.

  • PDF

소각로의 연소 공기 유동 해석 (Analysis of Combustion Air Flow in Incinerator)

  • 이동혁
    • Design & Manufacturing
    • /
    • 제16권2호
    • /
    • pp.26-32
    • /
    • 2022
  • It is known that the fluidized bed incinerator, which is the subject of analysis, shows excellent performance in heat and mass transfer due to excellent mixing and contact performance between fluidized sand and fuel, and also shows relatively good combustion characteristics thanks to good mixing and long residence time for low-grade fuels. have. In this study, air flow analysis is performed to understand the characteristics of co-firing of sludge, waste oil and solid waste in the fluidized bed incinerator, flow characteristics of flue gas, and discharge characteristics of pollutants.The fluidized bed incinerator subject to analysis is a facility that incinerates factory waste and general household waste together with sludge, with a processing capacity of 32 tons/day. to be. In addition, the operation method was designed for continuous operation for 24 hours. As a result, it can be seen that the lower combustion air and the introduced secondary air are changed to a strong turbulence and swirl flow form and exit through the outlet while rotating inside the freeboard layer. The homogeneous one-way flow form before reaching the secondary air nozzle has very high diffusivity with the high-speed jet flow of the nozzle.

공탑속도 및 과잉공기비에 따른 석탄유동층연소로의 조업특성 (Effect of Excess Air and Superficial Air Velocity on Operation Characteristics in a Fluidized Bed Coal Combustor)

  • 장현태;차왕석;태범석
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.84-92
    • /
    • 1999
  • The effects of air velocity and excess air on combustion characteristics were studied in a fluidized bed combustor. The domestic low-grade anthracite coal with heating value of 2010 kcal/kg and the imported bituminous coal from Australia with heating value of 6520 kcal/kg were used as coal samples. The combustion characteristics of mixed fuels in a fluidized bed combustor could be interpreted by pressure fluctuation properties, ash distribution and gas emission. The properties of the pressure fluctuations, such as the standard deviation, cross-correlation function, dominant frequency and the power spectral density function, were obtained from the statistical analysis. From this study, the combustion region increased with increasing air velocity but decreased with excess air due to combustion characteristics of anthracite and bituminous coal.

  • PDF

RDF 유동층 연소시 Cl의 거동 (Chlorine behavior during fluidized bed combustion of RDF)

  • 이혜문;곽연호;김우현
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.137-141
    • /
    • 2001
  • The behavior of Cl is important to prevent HCl exhausted by incineration of RDF. Because RDF is composed of municipal wastes, its calorific value is very various. Thus components of RDF are to be analyzed and elemental analyze and calorific value are to be done. And in order to find the behavior of Cl during RDF combustion, Cl included in exhaust gas and ash is captured and analyzed. RDF which made by municipal and $Ca(OH)_2$ with regular ratio(Ca/0.5Cl) is incinerated in fluidized bed combustor. Cl included in exhaust gas and fly ash is captured and analyzed. Finally the change of Cl concentration included in exhaust gas and ash is analyzed and the behavior of Cl is investigated.

  • PDF

실험실규모 순환유동층에서 RDF와 RPF의 연소 특성에 관한 연구 (Combustion of RDF and RPF in a Lab-Scale Circulating Fluidized Bed)

  • 이재성;이응록;안민하;박상욱;신동훈;황정호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.173-179
    • /
    • 2004
  • Combustion of refuse derived fuel(RDF) and refuse plastic fuel (RPF) was carried out in a lab-scale circulating fluidized bed. Experiment was investigated cold flow visualization. RDF was made by C & tech and RPF was made by KRS. The results include distribution of temperature in the combustion chamber, and concentrations of flue gas such as $O_2$, $CO_2$, CO, $NO_x$ and HCs Micro G.C(gas chromatograph) was employed to find out concentration of He Temperature distribution was different when RDF and RPF were burnt respectably. As air ratio became increased, $CO_2$, CO, and total of HCs emissions were decreased. According to the number of carbon atom of HCs, HC were classified as five kinds of HC.

  • PDF