• 제목/요약/키워드: fluid balance

검색결과 278건 처리시간 0.031초

카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계 (Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit)

  • 이성래
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Evaluation of Computational Fluid Dynamics for Analysis of Aerodynamics in Naturally Ventilated Multi-span Greenhouse

  • Lee, In Bok;Short, Ted H.;Sase, Sadanori;Lee, Seung Kee
    • Agricultural and Biosystems Engineering
    • /
    • 제1권2호
    • /
    • pp.73-80
    • /
    • 2000
  • Aerodynamics in a naturally ventilated multi-span greenhouse with plants was analyzed numerically by the computational fluid dynamics (CFD) simulation. To investigate the potential application of CFD techniques to greenhouse design and analysis, the numerical results of the CFD model were compared with the results of a steady-state mass and energy balance numerical model. Assuming the results of the mass and energy balance model as the standard, reasonably good agreement was obtained between the natural ventilation rates computed by the CFD numerical model and the mass and energy balance model. The steady-state CFD model during a sunny day showed negative errors as high as 15% in the morning and comparable positive errors in the afternoon. Such errors assumed to be due to heat storage in the floor, benches, and greenhouse structure. For a west wind of 2.5 m s$^{-1}$ , the internal nonporous shading screens that opened to the east were predicted to have a 15.6% better air exchange rate than opened to the west. It was generally predicted that the presence of nonporous internal shading screens significantly reduced natural ventilation if the horizontal opening of the screen for each span was smaller that the effective roof vent opening.

  • PDF

자성유체의 자유표면의 변형에 관한 수치해석 (Numerical Analysis on the Deformation of Free Surface of Magnetic Fluid)

  • 남성원;신산신일
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1995년도 추계 학술대회논문집
    • /
    • pp.132-137
    • /
    • 1995
  • Numerical analysis is conducted on the deformation of free surface of magnetic fluid. Steady magnetic fields are induced by a circular current loop. Governing equations of magnetic fields are solved by using the concept of vector potential. The free surface of magnetic fluid is formed by the balance of surface force, gravity, pressure difference, magnetic normal pressure and magnetic body force. The deformations of free surface of magnetic fluid are qualitatively clarified. And, the patterns of steady non-uniform magnetic fields induced by a circular current loop are quantitatively presented.

  • PDF

카운터 밸런스 밸브를 내장한 양방향 유압 브레이크 시스템 개발 (Development of double acting brake system integrated counter balance valve)

  • 김형의;이용범;윤소남;이일영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.962-967
    • /
    • 1991
  • A counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. In this study, for the purpose of easy estimation about dynamic characteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. Dynamic characteristics were analysed by numerical integration using Runge-Kutta method, because the equations in this circuit with counter balance valve contain various nonlinear terms. Propriety of this analysis method is verified by experiment. For the purpose of obtaining fundamental data for preventing instability, this study experimented the effects of the spool taper, spring constant, cylindrical choke. And we developed double acting brake system integrated counter balance valve.

  • PDF

유압 모터 브레이크 시스템의 동특성에 관한연구 (A study on Dynamic Characteristics of Hydraulic Motor Brake System Integrated Counter Balance Valve)

  • 윤소남;김형의
    • 한국기계연구소 소보
    • /
    • 통권20호
    • /
    • pp.27-32
    • /
    • 1990
  • A counter balance valve is used as one part of hydraulic motor brake system. The function of this valve is to protect over-run or free falling of inertia load. But occasionally the brake system with counter balance valve makes some undesirable problems such as pressure surges or vibrations. In this study, for the purpose of easy estimation about dynamic chrcteristics of hydraulic system including counter balance valve, precise formulation describing fluid dynamics and valve dynamics under various boundary conditions were made. dynamic caracteristics were analysed by numerical intergration using Runge-Kutta method, because the equations in this circuit with counter balance valve contain various nonlinear terms. So the analyzing method developed in this study enabled very easy estimating the relation between the performance of counter balance valve and various physical parameters related to the valve.

  • PDF

전자기력에 의한 자성유체의 2차원 자유표면 형상 제어에 관한 연구 (A Study on the Two-dimensional Formation Control of Free Surface of Magnetic Fluid by Electromagnetic Force)

  • 배형섭;양택주;이육형;주동우;박명관
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.29-37
    • /
    • 2005
  • In this study, the control of the free surface deformation of a magnetic fluid for the change in electromagnetic force is discussed. The free surface of magnetic fluid is formed by the balance of surface force, gravity, pressure difference, magnetic normal pressure and magnetic body force. Magnetic fluid in characteristics of fluid adjusted to the opposite direction of the gravity direction. Thus, the device of a magnetic fluid proposed the complete zero-leakage sealing, oscillator for surface control, boundary layer control, MHD, flow control, flow using magnetic levitation system and surface actuator. This study show the deformation of surface rise due to the intensity of the magnetic field and possibility of two-dimensional control of magnetic fluid through the feedback data of hall sensor.

THE EFFECT OF PHYSICAL CHARACTERISTICS OF HAY DIETS ON PHOSPHORUS METABOLISM IN SHEEP

  • Junluang, W.;Yano, F.;Yano, H.;Kawashima, R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권3호
    • /
    • pp.505-510
    • /
    • 1992
  • The experiments were carried out to study the effect of physical forms of hay diet on phosphorus metabolism by offering sheep roughage diets containing a low phosphorus content. The sheep were fed coarse hay, short hay or finely ground pelleted hay. The physical forms of hat diet had little effect on the pathway of phosphorus excretion. In all groups, the most of phosphorus was excreted in feces and urinary phosphorus excretion was negligible. Duodenal fluid flow, rumen fluid outflow and estimated salivary flow appeared to be relatively high in sheep fed the coarse hay diet as compared to those in sheep fed the finely ground diet. The amount of phosphorus flow to the duodenum tended to be high in the coarse diet group as compared to those in other two groups. On the other hand, phosphorus concentrations in the duodenal fluid and the rumen fluid were lower in sheep fed the coarse hay diet than those in sheep fed the ground hay. Net intestinal phosphorus absorption tended to be higher in sheep fed the coarse hay than that in sheep fed the ground hay or pelleted hay. However, a negative phosphorus balance was observed in the coarse hay diet group although a positive phosphorus balance was found in other two groups. It was considered that salivary phosphorus secretion was greater than the amount of salivary phosphorus reabsorbed from the intestine, resulting in the negative of phosphorus balance in sheep fed the coarse hay.

수액가온요법과 피부가온요법이 개복술 환자의 저체온 예방에 미치는 효과 비교 (A comparison of the Effects of Intravenous Fluid Warming and Skin Surface Warming on Peri-operative Body Temperature and Acid Base Balance of Elderly Patients with Abdominal Surgery)

  • 박효선;윤혜상
    • 대한간호학회지
    • /
    • 제37권7호
    • /
    • pp.1061-1072
    • /
    • 2007
  • Purpose: The purpose of this study was to compare the effects of intravenous fluid warming and skin surface warming on peri-operative body temperature and acid base balance of abdominal surgical patients under general anesthesia. Method: Data collection was performed from January 4th, to May 31, 2004. The intravenous fluid warming(IFW) group(30 elderly patients) was warmed through an IV line by an Animec set to $37^{\circ}C$. The skin surface warming(SSW) group(30 elderly patients) was warmed by a circulating-water blanket set to $38^{\circ}C$ under the back and a 60W heating lamp 40 cm above the chest. The warming continued from induction of general anesthesia to two hours after completion of surgery. Collected data was analyzed using Repeated Measures ANOVA, and Bonferroni methods. Results: SSW was more effective than IFW in preventing hypothermia(p= .043), preventing a decrease of $HCO_3{^-}$(p= .000) and preventing base excess(p= .000) respectively. However, there was no difference in pH between the SSW and IFW(p= .401) groups. Conclusion: We conclude that skin surface warming is more effective in preventing hypothermia, and $HCO_3{^-}$ and base excess during general anesthesia, and returning to normal body temperature after surgery than intravenous fluid warming; however, skin surface warming wasn't able to sustain a normal body temperature in elderly patients undergoing abdominal surgery under general anesthesia.

Association between Cumulative Fluid Balance and Outcomes in Acute Respiratory Distress Syndrome Patients Treated with Extracorporeal Membrane Oxygenation

  • Lee, Jun Hee;Won, Jong Yun;Kim, Ji Eon;Kim, Hee Jung;Jung, Jae Seung;Son, Ho Sung
    • Journal of Chest Surgery
    • /
    • 제54권1호
    • /
    • pp.36-44
    • /
    • 2021
  • Background: Extracorporeal membrane oxygenation (ECMO) has become increasingly accepted as a life-saving procedure for patients with severe acute respiratory distress syndrome (ARDS). This study investigated the relationship between cumulative fluid balance (CFB) and outcomes in adult ARDS patients treated with ECMO. Methods: We retrospectively analyzed the data of adult ARDS patients who received ECMO between December 2009 and December 2019 at Korea University Anam Hospital. CFB was calculated during the first 7 days after ECMO initiation. The primary endpoint was 28-day mortality. Results: The 74 patients were divided into survivor (n=33) and non-survivor (n=41) groups based on 28-day survival. Non-survivors showed a significantly higher CFB at 1-7 days (p<0.05). Cox multivariable proportional hazard regression revealed a relationship between CFB on day 3 and 28-day mortality (hazard ratio, 3.366; 95% confidence interval, 1.528-7.417; p=0.003). Conclusion: In adult ARDS patients treated with ECMO, a higher positive CFB on day 3 was associated with increased 28-day mortality. Based on our findings, we suggest a restrictive fluid strategy in ARDS patients treated with ECMO. CFB may be a useful predictor of survival in ARDS patients treated with ECMO.

내과 환자의 섭취량/배설량 측정법 비교 연구 (Comparison between Fluid Intake and Output Measurement Methods of the Patients Hospitalized in Medical Units)

  • 함경희;윤혜영;박소영;김은성;박근애;조세현;김민지;추성혜;김정연;이재길;이향규
    • 임상간호연구
    • /
    • 제22권1호
    • /
    • pp.20-27
    • /
    • 2016
  • Purpose: The purpose of this study was to compare the fluid intake and output (I&O) measurement methods in order to figure out more effective and easier method for medical patients Methods: 71 hospitalized patients participated in the study. In "liquid only (LO)" method, all amount of water was summed up including any liquid types of food and IV fluids. In "whole food(WF) intake," all liquid and solid food intake and IV fluids were added up. Results: The average amount of fluid intake was 2105.29 ml for LO method and 2523.54 ml for WF method. The average amount of fluid output was 2148.98 ml. The intra-class correlations (ICC) between the intake and output measures by the two different methods was 0.803 and 0.826, respectively. The correlation between the differences of intake/output and body weight change in two different methods was r=.347 (p=.003), and r=.376 (p=.001), respectively. Conclusion: The results of this study indicate that both LO and WF method may be useful in monitoring patients' fluid balance. Given the comparability of using LO over WF, it is suggested that measuring just liquid only intake as the indicator of patient's intake is applicable in clinical setting.