• 제목/요약/키워드: flow-feedback

검색결과 328건 처리시간 0.02초

피드백이 없는 유체진동기에서 분사되는 Sweeping jet의 유동 특성 (Flow Characteristics of Sweeping Jet Issued by a Feedback-free Fluidic Oscillator)

  • 남상현;김동욱;김경천
    • 한국가시화정보학회지
    • /
    • 제18권1호
    • /
    • pp.50-58
    • /
    • 2020
  • This paper presents flow characteristics of a sweeping jet issued by a feedback-free fluidic oscillator. Overall flow characteristics of feedback-free sweeping jet (FFSJ) were analyzed using flow visualization. The feedback-free sweeping jet has a sinusoidal external flow pattern. The oscillating frequency of the FFSJ is three times higher than that of a conventional sweeping jet at the same Reynolds number. Flow structure and turbulence characteristics were investigated using time-resolved particle image velocimetry (TR-PIV). In instantaneous velocity fields, the flow did not stay at ends but changed the direction continuously in contrast to the conventional sweeping jet. Velocity distributions at each plane which were extracted from mean velocity field has Gaussian distribution, which is similar with a circular jet. The sweep angles were constant as 45° at all Reynolds numbers in the high flow rate regime.

IMV 비례 유량제어밸브 정특성 선형해석 (Liner Analysis of IMV Proportional Flow Control Valve Static Characteristics)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권4호
    • /
    • pp.56-64
    • /
    • 2019
  • Recently, as the environmental regulation for earth moving equipment has been tightened, advanced systems using electronic control have been introduced for energy savings. An IMV(Independent Metering Valve), which consists of four 2-way valves, is one of the electro-hydraulic control systems that provides more flexible controllability and potential for energy savings in excavators, when compared to the conventional 4-way spool valve system. To fully realize an IMV, a two-stage bi-directional flow control valve which can regulate the large amount of flow in both directions, should be developed in advance. A simple design that allows proportional flow control to apply the pilot pressure from the current-controlled solenoid to the spring loaded flow control spool and thus valve displacement, is proportional to the solenoid current. However, this open-loop type valve is vulnerable to flow force which directly affects the valve displacement. Force feedback servo of which the position loop is closed by the feedback spring which interconnects the solenoid valve and flow control spool, could compensate for the flow force. In this study, linearity for the solenoid current input and robustness against load pressure disturbance is investigated by linear analysis of the static nonlinear equations for the IMV proportional flow control valve with feedback spring. Gains of the linear system confirm the performance improvement with the feedback spring design.

이러닝 환경에서 몰입학습 증진을 위한 대화 기반 피드백 시스템의 개발 (Development of Dialogue-based Feedback System to Improve Flow Learning in e-Learning Environment)

  • 정상목;송기상
    • 한국콘텐츠학회논문지
    • /
    • 제7권2호
    • /
    • pp.150-160
    • /
    • 2007
  • 교실수업에서는 지속적인 면대면 피드백을 통해 학습동기를 부여하고 학습 성취 욕구를 충족시켜주어 몰입학습을 유도 할 수 있으나 이러닝에서는 교실수업에 준하는 상호작용수준에 미치지 못하고 있어 많은 학습자들이 중도탈락이나 포기를 하고 있는 실정이다. 이러한 이러닝 환경에서의 문제점을 개선하고자 본 연구에서는 교실수업에서 사용하는 대화 피드백을 시스템에서 제공해 주어 학습자의 몰입학습을 증진시키는 대화 기반 피드백 시스템을 개발하였다. 개발된 시스템을 학교 현장에 적용해 보았으며, 그 결과 실험집단이 통제집단에 비해 학습자 개인에게 명확한 학습 목표의식과 도전감, 구체적인 피드백이 이루어져 몰입학습을 증진시킨 것으로 나타났다. 이는 본 시스템에서 제공해 주는 대화 기반 피드백이 학습자에게 적극적인 학습참여 자세를 배양하였고 학습의 흥미와 관심을 유지시켜 몰입학습을 유도하였음을 시사하고 있다. 끝으로 본 연구가 가지는 의의로 이러닝 환경에서 새로운 학습 시스템의 개발 방향을 제시하였다고 결론지을 수 있다.

Flow-Feedback for Pressure Fluctuation Mitigation and Pressure Recovery Improvement in a Conical Diffuser with Swirl

  • Tanasa, Constantin;Bosioc, Alin;Susan-Resiga, Romeo;Muntean, Sebastian
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.47-56
    • /
    • 2011
  • Our previous experimental and numerical investigations of decelerated swirling flows in conical diffusers have demonstrated that water jet injection along the symmetry axis mitigates the pressure fluctuations associated with the precessing vortex rope. However, for swirling flows similar to Francis turbines operated at partial discharge, the jet becomes effective when the jet discharge is larger than 10% from the turbine discharge, leading to large volumetric losses when the jet is supplied from upstream the runner. As a result, we introduce the flow-feedback approach for supplying the jet by using a fraction of the discharge collected downstream the conical diffuser. Experimental investigations on mitigating the pressure fluctuations generated by the precessing vortex rope and investigations of pressure recovery coefficient on the cone wall with and without flow-feedback method are presented.

굴삭기 IMV용 비례 유량제어밸브 정특성 해석 (Static Analysis of Dedicated Proportional Flow Control Valve for IMV)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.39-47
    • /
    • 2018
  • Recently, as environmental regulations for earth-moving equipment have been tightening, advanced systems such as electronic control, have been introduced for energy savings. An IMV (Independent Metering Valve) consisting of four 2-way valves, is an electro-hydraulic control systems that provides more flexible controllability, and potential for energy savings in excavators, when compared to the conventional 4-way spool valve system. To fully maximize use of an IMV, the bi-directional flow control valve that can regulate a large amount of flow in both directions, should be adopted. The hydraulic circuit of an IMV applied to an excavator from an overseas construction equipment company, reveals the flow control valve with the compound of proportional solenoid valve for first stage, and 2-way spool valve for the second stage. Moreover, the two spools are interconnected by a feedback spring, presumed to compensate for flow force acting on the second stage spool. This paper addresses the static analysis of flow control valve in an IMV to investigate the improvement of robustness, against flow force by the feedback spring. From the steady-state analysis of flow control valve model, it can be concluded that the feedback spring facilitates maintaining linearity of spool displacement for control input, and relatively constant flow for load disturbance.

시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구 (A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations)

  • 김용이;윤혜림;여명석
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

임의로 움직이는 물체 주위의 유동 해석을 위한 피드백 강제 외력을 이용한 가상경계방법 (AN IMMERSED BOUNDARY METHOD WITH FEEDBACK FORCING FOR SIMULATION OF FLOW AROUND AN ARBITRARILY MOVING BODY)

  • 신수재;황위희;성형진
    • 한국전산유체공학회지
    • /
    • 제12권2호
    • /
    • pp.14-20
    • /
    • 2007
  • We present an improved immersed boundary method for computing incompressible viscous flow around an arbitrarily moving body on a fixed computational grid. The main idea is to incorporate feedback forcing scheme of virtual boundary method with Peskin's regularized delta function approach in order to use large CFL number and transfer quantities between Eulerian and Lagrangian domain effectively. From the analysis of stability limits and effects of feedback forcing gains, optimum regions of the feedback forcing are suggested.

임의로 움직이는 물체 주위의 유동 해석을 위한 피드백 강제 외력을 이용한 가상경계방법 (AN IMMERSED BOUNDARY METHOD WITH FEEDBACK FORCING FOR SIMULATION OF FLOW AROUND AN ARBITRARILY MOVING BODY)

  • 신수재;황위희;성형진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 춘계 학술대회논문집
    • /
    • pp.23-29
    • /
    • 2007
  • We present an improved immersed boundary method for computing incompressible viscous flow around an arbitrarily moving body on a fixed computational grid The main idea is to incorporate feedback forcing scheme of virtual boundary method with Peskin's regularized delta function approach in order to use large CFL number and transfer quantities between Eulerian and Lagrangian domain effectively. From the analysis of stability limits and effects of feedback forcing gains, optimum regions of the feedback forcing are suggested.

  • PDF

NACA0015 익형의 압력항력 감소를 위한 인공신경망 기반의 피드백 유동 제어 (Feedback Flow Control Using Artificial Neural Network for Pressure Drag Reduction on the NACA0015 Airfoil)

  • 백지혜;박수형
    • 한국항공우주학회지
    • /
    • 제49권9호
    • /
    • pp.729-738
    • /
    • 2021
  • 본 연구에서는 실속 받음각 근처에 발생하는 익형 위의 유동박리를 억제하기 위하여 인공신경망 기반의 피드백 유동제어를 NACA0015 익형에 수치적으로 적용하였다. 익형 위 박리영역 크기의 축소화라는 제어 목표를 달성하기 위해 익형의 박리 지점 근처에 인위적 외란(Blowing & Suction) 제어 신호를 적용하였다. 유동의 운동을 나타내는 시스템 모델링 단계에서 압력데이터에 적합직교분해(Proper Orthogonal Decomposition)를 적용하여 유동제어에 필요한 운동 모드를 추출하고 유동의 특성을 분석하였다. 분해된 모드를 기반으로 NARX(Nonlinear AutoRegressive Exogenous) 구조의 인공 신경망을 학습하여 유동의 운동을 나타내도록 하였으며, 최종적으로 피드백 제어루프에 작동시켰다. 예측된 제어신호를 CFD 해석에 적용하였으며 제어 유/무에 따른 공력특성을 분석하고 익형 주변의 고유 공간모드의 변화를 비교하여 제어 효과를 분석하였다. 본 연구에서 진행된 피드백 제어는 약 29%의 압력항력 감소효과를 보여주었으며, 이는 익형 뒷전의 큰 압력회복으로 인해 나타나는 것을 확인하였다.

온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구 (An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol)

  • 김용이;임재한;한여명;김광우
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF