• Title/Summary/Keyword: flow separation

Search Result 1,780, Processing Time 0.028 seconds

Prediction of Turbulent Flows with Separation and Swirl Using the RNG K-$\varepsilon$ Turbulence Model (RNG k-$\varepsilon$ 난류모델을 이용한 유동박리 및 선회를 가지는 난류유동의 예측)

  • 김성구;오군섭;김용모;이창식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.5
    • /
    • pp.119-129
    • /
    • 1996
  • This study is concerned with the critical evaluation of predicative capability of a k-$\varepsilon$ turbulence model using the Renormalization Group(RNG) theory. The present numerical model for solution of the Navier-Stokes System is based on the modified PISO algorithms. Computations have been performed with the RNG-based K-$\varepsilon$ model for the two-dimensional flow over a backward-facing step, a confined coaxial jet, and a swirling flow in a swirl combustor. Numerical results are compared with experimental data in terms of mean flow velocities, turbulent kinetic energy, and turbulent stresses. Numerical results clearly indicate that the RNG-based K-$\varepsilon$ turbulence model shows a significant improvement over a standard K-$\varepsilon$ model in predicting the turbulent flows with flow separation and swirl.

  • PDF

Freezing Characteristics in a Horizontal Rectangular Channel with the Two-Dimensional Protuberances (2차원 직사각형 덕트 내부에 돌기부를 갖는 흐름의 동결특성에 관한 연구)

  • Oh, Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.721-727
    • /
    • 2003
  • Freezing of turbulent water flow between two horizontal cooled parallel plates with the separated region has been investigated experimentally. The flow separation was induced by vertical plates (two-dimensional plates) situated at the inlet of the rectangular channel. The degree of flow separation was varied by employing vertical thin plates with various heights. Three kinds of the vertical plates with 8.0, 9.8 and 12.5 mm in height were utilized. The Reynolds number and cooling temperature ratio were ranged from $3.45\times10^3 to 1.73\times10^4$ and 7.0 to 20.0 respectively, The measurements show that the flow separation influenced remarkably on the local ice formation characteristics. The location of the first ice layer and the average heat transfer at the ice surface were found be correlated as a function of the Reynolds number, the cooling temperature ratio, and the orifice height ratio.

FLOW SEPARATION PREDICTION ON TRANSONIC AIRCRAFT USING VARIOUS TURBULENCE MODELS (다양한 난류 모델을 이용한 천음속 항공기에서의 흐름 박리 예측)

  • Lee, Nam-Hun;Kwak, Ein-Keun;Lee, Seung-Soo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.420-427
    • /
    • 2011
  • In this study, numerical simulations of transonic aircraft configurations are performed with various turbulence models and the effect of turbulence models on flow separation are examined. A three-dimensional RANS code and three turbulence models are used for the study. The turbulence models incorporated to the code include Menter's ${\kappa}-{\omega}$ model, Coakley's $q-{\omega}$, and Huang and Coakley's ${\kappa}-{\omega}$, model. Using the code, numerical simulations of DLR-F6 configurations obtained from AIAA CFD Drag Prediction Workshop are conducted. Flow separations on the wing-body juncture and the wing lower surface near pylon are observed. and flow features of the regions are compared with experimental data and other numerical results.

  • PDF

Effect of Reynolds number on compressible convex-corner flows

  • Chung, Kung-Ming;Chang, Po-Hsiung;Chang, Keh-Chin
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.4
    • /
    • pp.443-454
    • /
    • 2014
  • An experimental study was conducted to investigate the effect of Reynolds number on compressible convex-corner flows, which correspond to an upper surface of a deflected flap of an aircraft wing. The flow is naturally developed along a flat plate with two different lengths, resulting in different incoming boundary layer thicknesses or Reynolds numbers. It is found that boundary layer Reynolds number, ranging from $8.04{\times}10^4$ to $1.63{\times}10^5$, has a minor influence on flow expansion and compression near the corner apex in the transonic flow regime, but not for the subsonic expansion flow. For shock-induced separated flow, higher peak pressure fluctuations are observed at smaller Reynolds number, corresponding to the excursion phenomena and the shorter region of shock-induced boundary layer separation. An explicit correlation of separation length with deflection angle is also presented.

Preparation of Microporous Silica Membrane from TEOS-$H_2O$ System and Separation Of $H_2$-$N_2$ Gas Mixture (TEOS-$H_2O$계로부터 다공성 실리카 막의 제조 및 수소-질소 혼합기체의 분리)

  • 강태범;이현경;이용택
    • Membrane Journal
    • /
    • v.10 no.2
    • /
    • pp.55-65
    • /
    • 2000
  • The porous silica membrane was prepared from Si(${OC}_2H_5)_4-H_2O$ system by sol-gel method. To investigate the characteristics of gels and porous silica membrane, we examined gels and porous silica membrane using TG-DTA, X-ray diffractometer, IR spectrophotometer, BET, SEM and TEM. The optimum mole ratio of Si(OC$_2$H$_{5}$)$_4$ : $H_2O$ $C_2$H$_{5}$OH for porous silica membrane was 1 : 4.5 : 4. The porous silica membrane was obtained by heat treatment of the gel above 700 $^{\circ}C$. The specific surface area of sintered gel was 3.8 $m^2$/g to 902.3 $m^2$/g at 100 $^{\circ}C$ to 1100 $^{\circ}C$ The pore size of sintered gel was in the range 20 $\AA$~ 50$\AA$. The particle size of sintered gel was 15 nm to 30 nm at 30$0^{\circ}C$ to 700$^{\circ}C$. The performance of the porous silica membrane was investigated for the separation of $H_2$/$N_2$ gas mixture. Gas separation through porous silica membrane depends upon Knudsen flow and surface flow. The veal separation factor($\alpha$) of $H_2$/$N_2$ was 5.17 at 155.15 cmHg and $25^{\circ}C$. The real separation factor($\alpha$), head separation factor($\beta$), and tail separation factor( $\bar{B}$) increased as the pressure of permeation cell Increased.sed.

  • PDF

A Numerical Study on the Characteristics of Flow Field, Temperature and Concentration Distribution According to Changing the Shape of Separation Plate of Kitchen Hood System (주방용 후드시스템의 분리판 형상 변화에 따른 유동장, 온도 및 농도특성에 관한 수치적 연구)

  • Lee, Kwang-Sub;Lee, Chang-Hee;Lim, Kyoung-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.177-185
    • /
    • 2006
  • This study aims deriving analysis the flow characteristic of kitchen hood system with using 3-D numerical analysis method and improving the system to expel pollutes more efficiently. To understand the flow characteristics of four models, this study only focuses on velocity field, temperature field, and concentration field varying with followings whether separation plate is set or not and the shapes of separation plates. The quantity of air, speed of exhaust fan and temperature and concentration of heating source are concerned as constant values. The three models having different shapes have one exhaust port and the model which has the vent at the closest position to where pollutes are generated is discovered to be the most efficient model. Compare to the initial model (having no separation plate), it was $1.4-1.9\%$ more efficient at temperature distribution and $9.4-11.9\%$ more at $CO_2$ concentration distribution.

Triboelectrostatic Separation System for Separation of PVC and PS Materials Using Fluidized Bed Tribocharger

  • Lee, Jae-Keun;Shin, Jin-Hyouk;Hwang, Yoo-Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1336-1345
    • /
    • 2002
  • A triboelectrostatic separation system using a fluidized bed tribocharger for the removal of PVC material in the mixture of PVC/PS plastics is designed and evaluated as a function of electric field strength, air flow rate, and the mixing ratio of two-component mixed plastics. It consists of a fluidized-bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PS particles can be imparted negative and positive surface charges, respectively, due to the difference in the work function values of plastics suspended in the fluidized-bed tribocharger, and can be separated by passing them through an external electric field. Experimental results show that separation efficiency is strongly dependent on the electric Deld strength and particle mixing ratio. In the optimum conditions of 150 Ipm air flow rate and 2.6 kV/cm electric field strength a highly concentrated PVC (99.1%) can be recovered with a yield of more than 99.2% from the mixture of PVC and PS materials for a single stage of processing.

A Study on the Optimal Conditions of the Biogas Sorting by Using the Polysulfone Membrane (다공성 분리막을 이용한 최적의 Bio-gas 분리인자 도출)

  • Lee, Seung-Won;Jeong, Chang-Hoon;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1011-1019
    • /
    • 2011
  • The objective of this research is to evaluate optimal conditions of permeability and selectivity on the polysulfone membrane for efficiency of separation of $CH_4$ by checking four factors which are temperature, pressure, gas compositions and gas flow rates. When higher pressure was applied at the input, lower efficiency of recovery of $CH_4$ and higher efficiency of separation of $CH_4$ were shown. It has the tendency to show lower efficiency of recovery of $CH_4$ and higher efficiency of separation of $CH_4$ at the output as higher temperature at input. The lower flow rates make higher efficiency of recovery of $CH_4$ and lower efficiency of separation of $CH_4$. Finally, over 90% efficiency for $CH_4$ separation and recovery conditions are temperature ($-5^{\circ}C$), pressure (8 bar), gas composition rate (6:4) ($CH_4:CO_2$) and gas flow rate ($5\ell$/min). These conditions make higher separation and recovery efficiency such as 90.1% and 92.1%, respectively.

Discrete Vortex Simulation of Turbulent Separated and Reattaching Flow With Local Perturbation (국소교란이 있는 난류박리 재부착유동의 이산와류 수치해석)

  • 정용만;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.479-491
    • /
    • 1994
  • Discrete vortex method was applied for simulating an active control of turbulent leading- edge separation bubble. The leading-edge separation zone was perturbed by a time-dependent sinusoidal perturbation of different frequencies and levels. In order to describe the local sinusoidal perturbation at the separation point, a source pulsation vortex technique was proposed. The present two-dimensional vortex simulations were qualitatively compared with the experimental results for a blunt circular cylinder, where perturbation was introduced along the square-cut leading edge of the cylinder $(Kiya et al.^{(6,7)}).$ It was found that the reattachment length attained a minimum point at low levels of perturbation and two minima at a moderate higher perturbation frequency. The effects of local perturbation on the evolution of leading-edge separation bubble were scrutinized by comparing the perturbed flow with the natural flow. These comparisons were made for the distributions of mean velocity and its velocity fluctuations, intermittency and wall velocity. The motions of instantaneous reattachment in the space-time domain were demonstrated, which were also compared with the experimental findings. In order to investigate the reduction mehanism of reattachment length in the separation bubble, various cross-correlations for velocity and pressure and the relevant convection velocities were evaluated. It was observed that the convection velocity was closely associated with its corresponding pulsationg frequency.

Study on Dividing Two-phase Annular flow in a Horizontal Micro T-junction (수평 마이크로 T 자관에서의 2상 환상류 유동분배에 관한 연구)

  • Lee, Jun-Kyoung;Jo, Seong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.16-22
    • /
    • 2011
  • The objective of the present study is to investigate the dividing two-phase flow in a horizontal micro T-junction with the same rectangular cross section, $800\;{\mu}m{\times}800\;{\mu}m$, experimentally. Air and water were used as the test fluids. The superficial velocity ranges of air and water were 15~20 m/s and 0.11~0.2 m/s, respectively. Dividing flow characteristics at the micro T-junction are different from those at the larger T-junctions (5~10 mm in hydraulic diameter). Compared with the results of previous works related with the T-junction with mini cross sections (about 5 mm), for lower range of gas separation, the fraction of the liquid separated through the branch decreases for the fixed fraction of the gas separation. But for higher range of gas separation, higher liquid separation could be found.