• Title/Summary/Keyword: flow resistance

Search Result 1,801, Processing Time 0.036 seconds

Performance Characteristics of a Loop Thermosyphon for Heat Source Cooling (열원 냉각용 루프 써모사이폰의 작동 특성)

  • Choi, Du-Sung;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1475-1483
    • /
    • 2004
  • Loop thermosyphon(LTS) has many good characteristics such as low thermal resistance, no power consumption, noiseless operation and small size. To investigate the overall performance of LTS, we have performed various experiments varying three parameters: input power of the heater, working fluid(water, ethanol, FC3283) and filling ratio of the working fluid. At a combination of these parameters, temperature measurements are made at many locations of the LTS. The temperature difference between the evaporator and the condenser is used to obtain the thermal resistance. In addition, flow visualization using a high speed camera is carried out. The thermal resistance is not constant. It is lower at higher input power, which is one of the distinct merits of LTS. Flow instabilities are frequently observed when changing the working fluid, the input power and the filling ratio. The results show that the LTS can be readily put into practical use. Future practical application in electronic cooling is recommended.

Heat Flow Analysis in the Newly Developed Wave Heat Sink by Computational Simulation (전산모사에 의한 웨이브 히트싱크의 열유동 특성 해석)

  • Lee In-Gyu;Lee Sang-Woong;Kang Kae-Myung;Chang Si-Young
    • Korean Journal of Materials Research
    • /
    • v.14 no.12
    • /
    • pp.870-875
    • /
    • 2004
  • Heat flow characteristics in the newly developed Wave Heat Sink were analyzed under natural and forced convections by Icepak program using the finite volume method. Temperature distribution and thermal resistance of Wave Heat Sink with/without air vent hole on the top of fin were compared with those of a commercial Al extruded heat sink(Intel Heat Sink). Under the natural convection, the maximum temperature was $45.1^{\circ}C$ in the air vent hole typed Wave Heat Sink, which was superior to that of Intel Heat Sink. The thermal resistance was $2.51^{\circ}C/W$ in the air vent hole typed Wave Heat Sink, and it changed to $2.65^{\circ}C/W\;and\;2.16^{\circ}C/W$ with changes of gravity direction and fin height, respectively. Under the forced convection, the maximum temperature became lower than that under the natural convection. In addition, the thermal resistance lowered in the air vent hole typed Wave Heat Sink with higher fin height and it decreased with increasing the air flux.

A Study on the Reduction the Thermal Contact Resistances at the Interface Between a Porous Metal Wick and Solid Heating Plate for a Circular Plate LHP (원판형 LHP 증발부의 소결 금속 윅에서의 접촉 저항에 관한 연구)

  • Jo, Jung-Rae;Choi, Jee-Hoon;Sung, Byung-Ho;Ki, Jae-Hyung;Ryoo, Seong-Ryoul;Kim, Chul-Ju
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2357-2362
    • /
    • 2008
  • LHP is different from a conventional heat pipes in design and heat and fluid flow passages. The situations of the former is much complex than the latter. In LHPs, evaporation occurs at the contact interface between the heating plate and the porous wick, so some micro channels machined at the contact interface serve to let the vapor flow out of the evaporator. This complexity of contact geometry was known to cause a high resistance to heat flow. The present work was to study the problem of heat passage across the contact surface for LHPs and determine those values contact resistance. For two cases of contact structures, the thermal contact resistances were examined experimentally, one being obtained through mechanical contact under pressure and the other through sintered bonding. Nickel powder wick and copper plate were used for specimens. The result showed that a substantial reduction of contact resistance of an order of degree could be obtainable by sintered bonding.

  • PDF

Optimizing the Configurations of Cooling Channels with Low Flow Resistance and Thermal Resistance (냉각유로 형상변화에 따른 유동 및 열저항 최적화 연구)

  • Cho, Kee-Hyeon;Ahn, Ho-Seon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this study, we investigated the hydrodynamic and thermal performance of constructal architectures on the basis of the mass flow rates for a given pressure drop, and we determined the thermal resistance and flow uniformity. The five flow configuration used in this study were the first construct with optimized hydraulic diameter, the second construct with optimized hydraulic diameter, the first construct with non-optimized hydraulic diameter, second construct with non-optimized hydraulic diameter, and a serpentine configuration. The results of our study suggest that the best fluid-flow structure is the second constructal structure with optimized constructal configurations. We also found that in the case of the optimized structure of cooling plates, the heat transfer was remarkably higher and the pumping power was significantly lower than those of traditional channels.

A Study on the Spacing between the Sand Drain Wells (모래기둥의 설치 간격에 관한 연구)

  • 김홍택
    • Geotechnical Engineering
    • /
    • v.8 no.1
    • /
    • pp.67-80
    • /
    • 1992
  • An analytical solution method is presented to determine the radius of influence circle of a sand 4rain well(i.e., spacing between the sand drain wells) required in the design under various types of construction loading. The proposed method deals with a sand drain well having a smeared zone at the periphery of the drain well as well as flow resistance in the drain well. The method proposed in the present study is made based on the modification of 01son's solution which deals with a single ramp loading without considering smeard zone effect as well as flow resistance in the drain well. Further, the effects of various design paramenters on the drain spacing are analyzed using the proposed method.

  • PDF

RESISTANCE OF COFFEE BEANS AND COFFEE CHERRIES TO AIR FLOW

  • Nordin Irbrahim, M.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.886-895
    • /
    • 1993
  • Experimental were conducted to obtain information on the effect of airflow rates and bed depths on the resistance of coffee cherries and coffee beans available locally (Coffea Liberica). The airflow used were in the range of 0.06 to 0.6 cu. m/s-sq.m. The moisture content of the coffee cherries ranged from 10 % to 50% (wet basis) and that of coffee beans ranged from 12% to 30% )wet basis). Two methods of filling were used i.e. loose fill and packed fill. Pressure drops across the material bed in a vertical column were measured at several depths using inclined manometer. The pressure drop increased directly with air flow rate as well as bed depths. The effects of air flowrates and moisture contents on the resistance in terms of pressure drip per unit bed depth were analysed. The pressure drop per unit depth across the material bed varied slightly due to different depth. The resistance to airflow decreased with the increase in moisture content for loose fill. However, the effect of moisture content is not apparent for packed fill.

  • PDF

Investigation of Abnormal Wear of Jig in Electric Resistance Welding (전기저항 용접 시 발생하는 지그의 비정상 마모현상 원인 분석)

  • Kim, Sun-Ho;Cho, Hang-Deuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • This paper presents an investigation of abnormal wear of a contact jig between a nail and a nail fixture in electric resistance welding. To perform an analysis on the abnormal wear phenomenon, several methods are provided. Based on the theory of electric resistance welding, are analyzed. Using microscopic analysis, surface craters are observed. In the measurement of the electric current flow in the nail fixture, the current flow distribution is measured. From several analyses, the cause of abnormal wear in the contact jig is measured using the electric discharge of high current density at the inflow point of the electric supply to the nail fixture. An alternative shape for normal wear is proposed.

Air Resistance Due to the Deflector Configuration of Commonly Used Largetrucks (상용 대형 트럭의 디플렉터 형상에 따른 공기저항력)

  • Han, Moonsik;Cho, Jaeung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.138-144
    • /
    • 2014
  • This study investigates the air resistance due to deflector configurations of commonly used largetrucksat a driving speedof 80 km/h. Of the 6 models that are considered, the drag causedby the pressure on the front part of the trailer is largest for model 1. For model 1, the lift caused by the difference between the velocities of the upper and lower streams isgreatest amongall the models. Model 6 has the least resistance against the flow stream consideringthedrags and lifts of theflow models. Anoptimal design can be obtainedby investigating thesimulation analysis ofvarious deflector configurationsfor the upper part of largetrucks; this optimum deflector configuration will help reduce the air resistanceon large trucks.

Numerical Analysis on the Wave Resistance for Development of Ship`s From of Tuna Purse Seiner (참치 선망어선의 선형개발을 위한 조파저항의 수치해석)

  • 김인철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.2
    • /
    • pp.228-239
    • /
    • 1992
  • The purpose of the present research is to develop an efficient numerical method for the calculation of potential flow and predict the wave-making resistance for the application to ship design of tuna purse seiner. The paper deals with the numerical calculation of potential flow around the series 60 with forward velocity by the new slender ship theory. This new slender ship theory is based on the asymptotic expression of the Kelvin-source, distributed over the small matrix at each transverse section so as to satisfy the approximate hull boundary condition due to the assumption of slender body. Some numerical results for series 60, C sub(b) =0.6, hull are presented in this paper. The wave pattern and wave resistance are computed at two Froude numbers, 0.267 and 0.304. These results are better than those of Michell's thin ship theory in comparison with measured results. However, it costs much time to compute not only wave resistance but also wave pattern over some range of Froude numbers. More improvements are strongly desired in the numerical procedure.

  • PDF

Effect of Contact Statistics on Electrical Contact Resistance (전기접촉저항에 관한 접촉통계치의 영향)

  • Jang, Yong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1080-1085
    • /
    • 2003
  • The flow of electrical current through a microscopic actual contact spot between two conductors is influenced by the flow through adjacent contact spots. A smoothed version of this interaction effect is developed and used to predict the contact resistance when the statistical size and spatial distribution of contact spots is known. To illustrate the use of the method, an idealized fractal rough surface is defined using the random midpoint displacement algorithm and the size distribution of contact spots is assumed to be given by the intersection of this surface with a constant height plane. With these assumptions, it is shown that including finer scale detail in the fractal surface, equivalent to reducing the sampling length in the measurement of the surface, causes the predicted resistance to approach the perfect contact limit.

  • PDF