• 제목/요약/키워드: flow of charge

검색결과 438건 처리시간 0.028초

Increasing P/E Speed and Memory Window by Using Si-rich SiOx for Charge Storage Layer to Apply for Non-volatile Memory Devices

  • 김태용;;김지웅;이준신
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.254.2-254.2
    • /
    • 2014
  • The Transmission Fourier Transform Infrared spectroscopy (FTIR) of SiOx charge storage layer with the richest silicon content showed an assignment at peaks around 2000~2300 cm-1. It indicated that the existence of many silicon phases and defect sources in the matrix of the SiOx films. The total hysteresis width is the sum of the flat band voltage shift (${\Delta}VFB$) due to electron and hole charging. At the range voltage sweep of ${\pm}15V$, the ${\Delta}VFB$ values increase of 0.57 V, 1.71 V, and 13.56 V with 1/2, 2/1, and 6/1 samples, respectively. When we increase the gas ratio of SiH4/N2O, a lot of defects appeared in charge storage layer, more electrons and holes are charged and the memory window also increases. The best retention are obtained at sample with the ratio SiH4/N2O=6/1 with 82.31% (3.49V) after 103s and 70.75% after 10 years. The high charge storage in 6/1 device could arise from the large amount of silicon phases and defect sources in the storage material with SiOx material. Therefore, in the programming/erasing (P/E) process, the Si-rich SiOx charge-trapping layer with SiH4/N2O gas flow ratio=6/1 easily grasps electrons and holds them, and hence, increases the P/E speed and the memory window. This is very useful for a trapping layer, especially in the low-voltage operation of non-volatile memory devices.

  • PDF

탄소펠트의 열처리 온도에 따른 레독스흐름전지와 전극 특성에 미치는 영향 (Effect of the redox flow battery and electrode characteristics according to the heat treatment temperature of a carbon felt)

  • 유효성;유현진;유기현;강준영;박홍식;최웅휘;유동진
    • 에너지공학
    • /
    • 제24권3호
    • /
    • pp.89-95
    • /
    • 2015
  • 레독스흐름전지의 전극으로 사용하기 위해 (주)CNF에서 제조한 탄소펠트를 여러 가지 온도에서 열처리하여 실험하였다. 열처리 조건에 따른 탄소펠트의 물성특성을 파악하기 위하여 BET(비표면적)와 무게감소를 측정하였고 표면특성을 살펴보기 위하여 주사전자현미경(SEM)과 XPS 분석을 실시하였다. 또한 전기저항, CV(cyclic voltammetry), RFB 충방전 성능 통해 열처리 조건에 따른 전극특성에 미치는 영향을 살펴보았다. SEM, BET분석을 통하여 탄소펠트 표면의 물성 변화를 확인하였고, XPS 분석을 통해 $550^{\circ}C$에서 1시간 열처리한 탄소펠트의 표면에 산소 관능기가 가장 많이 부가된 것을 확인하였다. CV 실험을 수행한 결과 $550^{\circ}C$ 열처리 전극의 활성면적이 가장 컸다. $400^{\circ}C$, $500^{\circ}C$, $550^{\circ}C$에서 열처리한 탄소펠트를 이용하여 바나듐 레독스흐름전지를 구성하고 충-방전 실험을 실시한 결과 충-방전 에너지효율이 $400^{\circ}C$ 열처리 전극의 경우 72.9%, $500^{\circ}C$ 열처리 전극의 경우 79.8%, $550^{\circ}C$ 열처리 전극의 경우 79.8%로 $550^{\circ}C$ 열처리 전극이 가장 우수하였다.

축제 방문객의 참여동기가 참여몰입 및 참여만족에 미치는 영향 (Effects of Visitors' Motivation for Attending Festivals on Their Participation Flow and Satisfaction)

  • 안대희;이낙귀
    • 한국콘텐츠학회논문지
    • /
    • 제9권2호
    • /
    • pp.391-399
    • /
    • 2009
  • 본 연구의 목적은 축제 방문객의 참여동기가 참여몰입 및 참여만족에 어떠한 영향을 미치는지를 살펴보고자 하는 것이다. 이를 위해 실증조사를 실시한 결과는 다음과 같다. 첫째, 일상탈출, 신기성 요인이 높을수록 참여몰입도 높아지는 것으로 나타났다. 둘째, 이벤트매력성, 사교성, 가족친화성이 높을수록 참여몰입도는 높아지는 것으로 나타났다. 셋째, 참여만족에는 참여동기 중외적 동기보다 내적 동기가 더 큰 영향을 미치는 것으로 나타났다. 넷째, 참여몰입이 높아질수록 참여만족도가 높아지는 것으로 나타났다. 이러한 결과는 축제 관계자에게 중요한 전략적 시사점을 제공해 줄 수 있을 것이다.

컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법 (A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera)

  • 박종원
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권1호
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

단일 프레임 입자 추적법을 이용한 흡입 2밸브 가솔린 기관의 실린더 내 정상 유동 해석 (Analysis of in-cylinder steady flow for dual-intake-valve gasoline engine using single-frame particle tracking velocimetry)

  • 이창식;이기형;임경수;전문수
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.650-658
    • /
    • 1997
  • Analysis and control of intake charge motion such as swirl and tumble are very important factors in improving the gasoline engine performance. In this paper, single-frame PTV (particle tracking velocimetry) is used to investigate intake tumble patterns in a steady flow test rig of gasoline engine with dual-intake-valve and pent-roof combustion chamber. Intake tumble pattern is quantified in accordance with blockage ratio of TIV (tumble intensifying valve) with single- frame PTv.The view of the instantaneous 2-D velocity field gives a realistic understanding of in-cylinder flow field. Thus it is confirmed that PTV is a effective tool in engine design. In conventional port, two tumble structures appear clearly, and the larger one is observed under the exhaust valve side and the smaller is right below the intake valve side. The larger vorticity is observed in TIV port, thus it is concluded that TIV have an effect on intensified tumble motion in cylinder flow.

최적조류계산을 이용한 한계손실계수의 전력시장 적용 (Marginal Loss Factor using Optimal Power flow in Power Market)

  • 신동준;고용준;이효상;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.379-384
    • /
    • 2002
  • In the competitive electricity market, various pricing methods are developed and practiced in many countries. Among these pricing methods, marginal loss factor(MLF) can be applied to reflect the marginal cost of network losses. For the calculation of MLF, power flow method has been used to calculate system loss deviation. However, this power flow method shows some shortcomings such as necessity of regional reference node, and absence of an ability to consider network constraints like line congestion, voltage limit, and generation output limit. The former defect might affects adversely to the equity of market participants and the latter might generate an inappropriate price signals to customers and generators. To overcome these defects, the utilization of optimal power flow(OPF) is suggested to get the system loss deviation in this paper. 30-bus system is used for the case study to compare the MLF results by the power flow and the OPF method for 24-hour dispatching and pricing, Generator payment and customer charge are compared with these two methods also. The results show that MLF by OPF reflects the power system condition more faithfully than that of by the conventional power flow method

고다공성 카본 에어로젤(C-Aerogel) 표면 특성 (Surface Properties of the High Porous Carbon Aerogels)

  • 김지혜;이창래;정용수;김양도;김인배
    • 한국표면공학회지
    • /
    • 제41권3호
    • /
    • pp.114-120
    • /
    • 2008
  • The pyrolysized carbon xerogel and aerogels were prepared from the sol-gel polymerization of resorcinol-formaldehyde(RF) followed by the dry process under ambient pressure and supercritical carbon dioxide condition respectively. The thermal behaviour of RF polymer xerogel was investigated with TGA analyzer to correspond with the pyrolysis process. The surface properties such as particle size, morphology and the point of zero charge of the pyrolysized porous carbon aerogels were studied for the precious metal catalyst supported media. It was found that the volume of the polymer aerogel decreased because of the significant linear shrinkage and weight loss of polymer gel during the carbonization. The point of zero charge of the carbon aerogel pyrolysized at $1050^{\circ}C$ under inert gas flow was about 10.

활성탄으로 코팅된 전극에서 분진의 제거 (Removal of Dust in Positive and Negative Plates of Electrode Coated with Activated Carbon)

  • 김광수;박현철;전태환;이주행;남상철
    • 한국대기환경학회지
    • /
    • 제29권6호
    • /
    • pp.830-837
    • /
    • 2013
  • The purposes of this research are to know the dust removal efficiency according to the changes of gab between positive and negative plates in dust removal chamber. The experiments for dust removal efficiencies were conducted with changing the electrode-plate gab from 2 cm to 1 cm while the electric pressure, influent flow, and linear velocity were kept 5 kV, 80 L/min, and 6 cm/sec, respectively. From the experimental results of the electrode-plate gab of 2 cm, dust removal efficiencies were decreased to as low as about 50%. Attached dust on the surface of electrodes was released due to a reverse electric charge of dust. From the experimental results of the electrode-plate gab of 1 cm, dust removal efficiencies were increased to as high as about 80% due to the dust attachment velocity to the electrodes to be far more fast than influent linear velocity. Finally, to protect a attached dust from occurring a reverse electric charge it is needed to install the non-conductor between positive and negative electrodes and also to remove air humidity.

DYNAMIC SIMULATION MODEL OF A HYBRID POWERTRAIN AND CONTROLLER USING CO-SIMULATION-PART II: CONTROL STRATEGY

  • Cho, B.;Vaughan, N.D.
    • International Journal of Automotive Technology
    • /
    • 제7권7호
    • /
    • pp.785-793
    • /
    • 2006
  • The topic of this study is the control strategy of a mild hybrid electric vehicle (HEV) equipped with a continuously variable transmission (CVT). A brief powertrain and vehicle configuration is introduced followed by the control strategy of the HEV with emphasis on two key parts. One of them is an ideal operating surface (IOS) that operates the CVT powertrain optimally from the viewpoint of the tank-to-wheel efficiency. The other is a charge sustaining energy management to maintain the battery state of charge (SOC) within an appropriate level. The fuel economy simulation results of the HEV over standard driving cycles were compared with those of the baseline vehicle. Depending on the driving cycle, 1.3-20% fuel saving potential is predicted by the mild hybridisation using an integrated starter alternator (ISA). The detailed energy flow analysis shows that the majority of the improvement comes from the idle stop function and the benefits for electrical accessories. Additionally, the differences between the initial and the final SOC are in the range $-1.0{\sim}+3.8%$ in the examined cycle.

CCD Image Sensor with Variable Reset Operation

  • Park, Sang-Sik;Uh, Hyung-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권2호
    • /
    • pp.83-88
    • /
    • 2003
  • The reset operation of a CCD image sensor was improved using charge trapping of a MOS structure to realize a loe voltage driving. A DC bias generating circuit was added to the reset structure which sets reference voltage and holds the signal charge to be detected. The generated DC bias is added to the reset pulse to give an optimized voltage margin to the reset operation, and is controlled by adjustment of the threshold voltage of a MOS transistor in the circuit. By the pulse-type stress voltage applied to the gate, the electrons and holes were injected to the gate dielectrics, and the threshold voltage could be adjusted ranging from 0.2V to 5.5V, which is suitable for controlling the incomplete reset operation due to the process variation. The charges trapped in the silicon nitride lead to the positive and negative shift of the threshold voltage, and this phenomenon is explained by Poole-Frenkel conduction and Fowler-Nordheim conduction. A CCD image sensor with $492(H){\;}{\times}{\;}510(V)$ pixels adopting this structure showed complete reset operation with the driving voltage of 3.0V. The resolution chart taken with the image sensor shows no image flow to the illumination of 30 lux, even in the driving voltage of 3.0V.