• Title/Summary/Keyword: flow mode

Search Result 1,376, Processing Time 0.032 seconds

Evaluation of Dynamic Lane Allocation Method at Climbing Lane Section (통행속도에 기반한 오르막차로 동적 운영방안 평가)

  • Ko, Han-Geom;Choi, Yoon-Hyuk;Oh, Young-Tae;Kang, Jeong-Gyu
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.1
    • /
    • pp.59-72
    • /
    • 2012
  • In aspects of traffic operation, a climbing lane may cause traffic congestion if the volume of traffic (v/c) grows and the ratio of heavy vehicle increases. Conversely, it would be effective, if the climbing lane is dynamically operated according to changes in traffic flow. However, there are no guideline to effectively control this climbing lane in aspects of traffic operation. In this study, we examine the necessity of flexible traffic operation criteria and its process for dynamic traffic management and also establish and analyze the effect of flexible traffic operation criteria in accordance with traffic properties using an example of climbing lane. We selected the operation criteria (critical travel speed), which decides whether to operate or close the climbing lane when the average travel speed of climbing lane is 50km/h based on VISSM (microscopic traffic simulation) analysis of Nakdong junction towards Masan with the volume of traffic (v/c), ratio of heavy vehicle as the traffic operation parameters. Based on the simulation result in accordance with the volume of traffic by the operation mode of climbing lane, the analysis on the effect of dynamic traffic management of climbing lane showed that the dynamic traffic management provides more convenience compare to the operation and close of climbing lane. Thereby, we proved that the dynamic traffic management of climbing lane is more effective.

Solid Phase Extraction(SPE) of Curcuminoids from Turmeric by Optimization Analytical Condition (최적 분석조건에 의한 강황으로부터 Curcuminoids의 고체상추출(SPE))

  • Lee, Kwang Jin;Ma, Jin Yeul;Kim, Young Jun;Kim, Young Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4927-4935
    • /
    • 2012
  • Turmeric is a medicinal herb with various pharmacological activities. Curcumin, demethoxycurcumin(DMC) and bisdemethoxycurcumin(BDMC) were extracted from turmeric by dipping and ultrasonic wave method. And extraction efficiency was identified using solid phase extraction(SPE). The extracted sample were simultaneously separated and analyzed from three kinds of commercial $C_{18}$ reversed-phase high performance liquid chromatography using water and acetonitrile as mobile phase with isocratic elution mode. Flow rate 1.0mL/min, injection volume $10{\mu}L$ and column oven temperature $40^{\circ}C$ at 425nm wavelength has been conducted. From the experimental results, the optimum mobile phase composition of water/acetonitrile 50/50vol% using RS tech column. It is evident that the amount of curcuminoids extracted(extraction time 4h) by 100% MeOH was higher than any aqueous MeOH composition. Finally, in 100% water extraction, the amount(mAU${\times}$mim) of curcuminoids extracted by SPE was 14.3 and 24.5 times respectively higher than ultrasonic wave and dipping method. The shown results can be applied as sources for pharmaceuticals and functional material.

Liquid Chromatography Quadrupole Time-Of-Flight Tandem Mass Spectrometry for Selective Determination of Usnic Acid and Application in Pharmacokinetic Study

  • Fang, Minfeng;Wang, Hui;Wu, Yang;Wang, Qilin;Zhao, Xinfeng;Zheng, Xiaohui;Wang, Shixiang;Zhao, Guifang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1684-1688
    • /
    • 2013
  • A rapid and sensitive method for determining usnic acid of Lethariella cladonioides in rat was established using high performance liquid chromatography (HPLC) quadrupole time-of-flight (QTOF) tandem mass (MS/MS). Rat plasma was pretreated by mixture of acetonitrile and chloroform to precipitate plasma proteins. Chromatographic separation was achieved on a column ($50{\times}2.1$ mm, $5{\mu}m$) with a mobile phase consisting of water (containing $5{\times}10^{-3}$ M ammonium formate, pH was adjusted to 3.0 with formic acid) and acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. A tandem mass spectrometric detection with an electrospray ionization (ESI) interface was conducted via collision induced dissociation (CID) under negative ionization mode. The MS/MS transitions monitored were m/z 343.0448 ${\rightarrow}$ m/z 313.2017 for usnic acid and m/z 153.1024 ${\rightarrow}$ m/z 136.2136 for protocatechuic acid (internal standard). The linear range was calculated to be 2.0-160.0 ng/mL with a detection limit of 3.0 pg/mL. The inter- and intra-day accuracy and precision were within ${\pm}7.0%$. Pharmacokinetic study showed that the apartment of usnic acid in vivo confirmed to be a two compartment open model. The method was fully valid and will probably be an alternative for pharmacokinetic study of usnic acid.

Frame-Layer H.264 Rate Control for Scene-Change Video at Low Bit Rate (저 비트율 장면 전환 영상에 대한 향상된 H.264 프레임 단위 데이터율 제어 알고리즘)

  • Lee, Chang-Hyun;Jung, Yun-Ho;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.127-136
    • /
    • 2007
  • An abrupt scene-change frame is one that is hardly correlated with the previous frames. In that case, because an intra-coded frame has less distortion than an inter-coded one, almost all macroblocks are encoded in intra mode. This breaks up the rate control flow and increases the number of bits used. Since the reference software for H.264 takes no special action for a scene-change frame, several studies have been conducted to solve the problem using the quadratic R-D model. However, since this model is more suitable for inter frames, the existing schemes are unsuitable for computing the QP of the scene-change intra frame. In this paper, an improved rate control scheme accounting for the characteristics of intra coding is proposed for scene-change frames. The proposed scheme was validated using 16 test sequences. The results showed that the proposed scheme performed better than the existing H.264 rate control schemes. The PSNR was improved by an average of 0.4-0.6 dB and a maximum of 1.1-1.6 dB. The PSNR fluctuation was also in proved by an average of 18.6 %.

Strength and failure characteristics of the rock-coal combined body with single joint in coal

  • Yin, Da W.;Chen, Shao J.;Chen, Bing;Liu, Xing Q.;Ma, Hong F.
    • Geomechanics and Engineering
    • /
    • v.15 no.5
    • /
    • pp.1113-1124
    • /
    • 2018
  • Geological dynamic hazards during deep coal mining are caused by the failure of a composite system consisting of the rock and coal layers, whereas the joint in coal affects the stability of the composite system. In this paper, the compression test simulations for the rock-coal combined body with single joint in coal were conducted using $PFC^{2D}$ software and especially the effects of joint length and joint angle on strength and failure characteristics in a rock-coal combined body were analyzed. The joint length and joint angle exhibit a deterioration effect on the strength and affect the failure modes. The deterioration effect of joint length of L on the strength can be neglected with a tiny variation at ${\alpha}$ of $0^{\circ}$ or $90^{\circ}$ between the loading direction and joint direction. While, the deterioration effect of L on strength are relatively large at ${\alpha}$ between $30^{\circ}$ and $60^{\circ}$. And the peak stress and peak strain decrease with the increase of L. Additionally, the deterioration effect of ${\alpha}$ on the strength becomes larger with the increase of L. With the increase of ${\alpha}$, the peak stress and peak strain first decrease and then increase, presenting "V-shaped" curves. And the peak stress and peak strain at ${\alpha}$ of $45^{\circ}$ are the smallest. Moreover, the failure mainly occurs within the coal and no apparent failure is observed for rock. At ${\alpha}$ between $30^{\circ}$ and $60^{\circ}$, the secondary shear cracks generated in or close to the joint tips, cause the structural instability failure of the combined body. Therefore, their failure models present as a shear failure along partial joint plane direction and partially cutting across the coal body or a shear failure along the joint plane direction. However, at ${\alpha}$ of $60^{\circ}$ and L of 10 mm, the "V-shaped" shear cracks cutting across the coal body cause its final failure. While crack nucleations at ${\alpha}$ of $0^{\circ}$ or $90^{\circ}$ are randomly distributed in the coal, the failure mode shows a V-shaped shear failure cutting across the coal body.

Characteristics of amorphous IZTO-based transparent thin film transistors (비정질 IZTO기반의 투명 박막 트렌지스터 특성)

  • Shin, Han-Jae;Lee, Keun-Young;Han, Dong-Cheul;Lee, Do-Kyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.151-151
    • /
    • 2009
  • Recently, there has been increasing interest in amorphous oxide semiconductors to find alternative materials for an amorphous silicon or organic semiconductor layer as a channel in thin film transistors(TFTs) for transparent electronic devices owing to their high mobility and low photo-sensitivity. The fabriction of amorphous oxide-based TFTs at room temperature on plastic substrates is a key technology to realize transparent flexible electronics. Amorphous oxides allows for controllable conductivity, which permits it to be used both as a transparent semiconductor or conductor, and so to be used both as active and source/drain layers in TFTs. One of the materials that is being responsible for this revolution in the electronics is indium-zinc-tin oxide(IZTO). Since this is relatively new material, it is important to study the properties of room-temperature deposited IZTO thin films and exploration in a possible integration of the material in flexible TFT devices. In this research, we deposited IZTO thin films on polyethylene naphthalate substrate at room temperature by using magnetron sputtering system and investigated their properties. Furthermore, we revealed the fabrication and characteristics of top-gate-type transparent TFTs with IZTO layers, seen in Fig. 1. The experimental results show that by varying the oxygen flow rate during deposition, it can be prepared the IZTO thin films of two-types; One a conductive film that exhibits a resistivity of $2\times10^{-4}$ ohm${\cdot}$cm; the other, semiconductor film with a resistivity of 9 ohm${\cdot}$cm. The TFT devices with IZTO layers are optically transparent in visible region and operate in enhancement mode. The threshold voltage, field effect mobility, on-off current ratio, and sub-threshold slope of the TFT are -0.5 V, $7.2\;cm^2/Vs$, $\sim10^7$ and 0.2 V/decade, respectively. These results will contribute to applications of select TFT to transparent flexible electronics.

  • PDF

Clinical Application of Acute Ischemic Stroke in Perfusion Computed Tomography (초급성 허혈성 뇌졸중에서 관류 전산화단층촬영의 임상적 적용에 대한 연구)

  • Lee, Jong-Seok;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.149-160
    • /
    • 2007
  • Recent advent of 64-multidetctor (MD) CT enables more coverage of Z-axis in the perfusion imaging. The purpose of this study was to evaluate the clinical usefulness of perfusion CT by using 64-MD CT in detecting the lesion in patients with acute stroke. The perfusion CT was performed by using 64-MD CT in 62 consecutive patients who were initially suspected to have subacute ischemic stroke symptoms during the period of recent 9 months. These patients had subacute stroke (n=62). CT scanning was conducted with Jog Mode which provided 16 imaging slices with 5 mm of slice thickness, and 8 cm of coverage in Z-axis. Scan interval was 1 seconds for each imaging slice and total 15 scans were repeated. After CT scanning, perfusion maps (CBV, CBF, MTT and TTP) were created at Extended Brilliance Workstation. The CBV and CBF maps showed that lesions were smaller images. While on the MTT and TTP map lesions were seen to be larger fifty-one were large than they appeared on these images. Two slices of perfusion maps obtained at the level of the basal ganglia were chosen to simulate conventional older perfusion CT with 8 cm of coverage in Z-axis. TTP and MTT maps may be clinically useful for evaluation of the penumbral zone in cases of aubacute cerebral ischemic stroke. The perfusion CT is useful in the assessment of acute stroke as an initial imaging modality.

  • PDF

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Determination of Fructooligosaccharides and Raffinose in Infant Formula by High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSC를 이용한 조제분유 중 fructooligosaccharides 및 raffinose 분석)

  • Shin, Man-Sub;Park, Jae-Woo;Cho, Mi-Ran;Song, Sung-Ok;Kim, Chun-Sun;Choi, Chun-Bae;Lee, Seoung-Won;Lee, Ki-Woong;Chang, Chi-Hoon;Kwak, Byung-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.725-729
    • /
    • 2006
  • A method was developed for the determination of fructooligosaccharides and raffinose contents in infant formula. The samples were extracted and analyzed by liquid chromatography equipped with carbohydrate column and evaporative light scattering detector. The mobile phase used for the gradient mode was water-acetonitrile, at a flow rate of 1.0mL/min. The method showed a mean recovery of 95-99%, the relative standard deviation obtained in the precision study was 0.774-8.982%, the quantification and detection limits were 25-50mg/L.

Effects of Corrugated GFRP Shear Connector Width and Pitch on In-plane Shear Behavior of Insulated Concrete Sandwich Wall Panels (CSWP) (파형 GFRP 전단연결재의 폭 및 너비에 따른 중단열 벽체의 면내전단거동)

  • Jang, Seok-Joon;Oh, Tae-Sik;You, Young-Chan;Kim, Ho-Royng;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.421-428
    • /
    • 2014
  • This paper describes the experimental results of insulated concrete sandwich wall panels (CSWP) with corrugated glass fiber-reinforced polymer (GFRP) shear connectors under in-plane shear loading. Corrugated GFRP shear connectors were used to improve the thermal property of insulated CSWP and to achieve composite action between the interior and exterior concrete wall panels. Test specimens were consist of three concrete panels with two insulation layers between concrete panels and middle concrete panels was loaded in the direction of gravity. To evaluate the effects of insulation types (extruded polystyrene, XPSS and expanded polystyrene, EPS), shear connector pitch (300 and 400 mm) and width (10 and 15 mm) on in-plane shear behavior of insulted CSWP, failure mode and shear flow-average relative slip relationship of specimens were investigated. Test results indicate that the bond stress between concrete panel and insulation is considerable initially. Especially in case of insulated CSWP without shear connector, initial stiffness of CSWP with XPSS is superior to that of CSWP with EPS. The shear connector's contribution to in-plane shear performance of insulated CSWP depends on the type of insulation.