• Title/Summary/Keyword: flow mode

Search Result 1,376, Processing Time 0.031 seconds

A Delay and Sensitivity of Delay Analysis for Varying Start of Green Time at Signalized Intersections: Focused on through traffic (신호교차로의 출발녹색시간 변화에 따른 직진교통류의 지체 및 지체민감도 분식)

  • Ahn, Woo-Young
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.21-32
    • /
    • 2007
  • The linear traffic model(Vertical queueing model) that is adopted widely in traffic flow estimation assumes that all vehicles have the identical motion before joining a queue at the stop-line. Thus, a queue is supposed to form vertically not horizontally. Due to the simplicity of this model, the departure time of the leading vehicle is assumed to coincide with the start of effective green time. Thus, the delay estimates given by the Vertical queueing model is not always realistic. This paper explores a microscopic traffic model(a Kinematic Car-following model at Signalised intersections: a KCS traffic model) based on the one dimensional Kinematic equations in physics. A comparative evaluation in delay and sensitivity of delay difference between the KCS traffic model and the previously known Vertical queueing model is presented. The results show that the delay estimate in the Vertical queueing model is always greater than or equal to the KCS traffic model; however, the sensitivity of delay in the KCS traffic model is greater than the Vertical queueing model.

  • PDF

MODAL TESTING AND MODEL UPDATING OF A REAL SCALE NUCLEAR FUEL ROD

  • Park, Nam-Gyu;Rhee, Hui-Nam;Moon, Hoy-Ik;Jang, Young-Ki;Jeon, Sang-Youn;Kim, Jae-Ik
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.821-830
    • /
    • 2009
  • In this paper, modal testing and finite element modeling results to identify the modal parameters of a nuclear fuel rod as well as its cladding tube are discussed. A vertically standing full-size cladding tube and a fuel rod with lead pellets were used in the modal testing. As excessive flow-induced vibration causes a failure in fuel rods, such as fretting wear, the vibration level of fuel rods should be low enough to prevent failure of these components. Because vibration amplitude can be estimated based on the modal parameters, the dynamic characteristics must be determined during the design process. Therefore, finite element models are developed based on the test results. The effect of a lumped mass attached to a cladding tube model was identified during the finite element model optimization process. Unlike a cladding tube model, the density of a fuel rod with pellets cannot be determined in a straightforward manner because pellets do not move in the same phase with the cladding tube motion. The density of a fuel rod with lead pellets was determined by comparing natural frequency ratio between the cladding tube and the rod. Thus, an improved fuel rod finite element model was developed based on the updated cladding tube model and an estimated fuel rod density considering the lead pellets. It is shown that the entire pellet mass does not contribute to the fuel rod dynamics; rather, they are only partially responsible for the fuel rod dynamic behavior.

유도 결합 플라즈마를 이용한 스퍼터-승화 증착 시스템의 공정 분석

  • Yu, Yeong-Gun;Choe, Ji-Seong;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.186-186
    • /
    • 2013
  • 종래의 흑연 위주 연료전지 분리판 개발되어 최근 고분자 전해질 막 연료전지가 높은 전력, 낮은 배기 가스 배출, 낮은 작동 온도로 자동차 산업에서 상당한 주목을 받고 있다. 요구사항은 높은 전기 전도도, 높은 내식성, 낮은 가스 투과성, 낮은 무게, 쉬운 가공, 낮은 제조비용이다. Thin film Cr 장비로 저항가열 furnace, sputter 등이 사용된다. 연료전지 분리판의 고전도도, 내부식성 보호막의 고속 증착을 위한 새로운 증착원으로 스퍼터 - 승화형 소스의 가능성을 유도 결합 플라즈마에 금속 봉을 직류 바이어스 함으로써 시도하였다. 유도 결합 플라즈마를 이용하여 승화증착 시스템을 사용하여 OES (SQ-2000)와 QMS (CPM-300)를 사용하여 $N_2$ flow에 따른 유도 결합 플라즈마를 이용한 스퍼터-승화증착 시스템을 사용 하여도 균일한 공정을 하는 것을 확인 하였다. 5 mTorr의 Ar 유도 결합 플라즈마를 2.4 MHz, 500 W로 유지하면서 직류 바이어스 전력을 30 W (900 V, 0.02 A) 인가하고, $N_2$의 유량을 0.5, 1.0, 1.5 SCCM로 변화를 주어 특성을 분석하였다. MID (Multiple Ion Detection) mode에서 유도결합 플라즈마를 이용한 스퍼터-승화 증착 장비를 사용하여 CrN thin flim 성장시켰고, deposition rate은 44.8 nm/min으로 얻을 수 있었다. 또한 $N_2$의 유량이 증가할 수록 bias voltage가 증가하는 것을 확인 할 수 있었다. OES time acquisition을 이용한 공정 분석에서는 $N_2$ 유량을 off 하였을 때 Ar, Cr의 중성 intensity peak이 상승하였고, 시간 경과에 따라 sublimation에 의한 영향이 없는 것을 확인 할 수가 있었다. XRD data에서는 질소 유량이 증가함에 따라 $Cr_2N$이 감소하고, CrN이 증가하는 것을 확인할 수가 있었다. 결정배향성과 Morphology는 다결정 재료의 경도에 영향을 주는 인자이다. CrN 결정 구조의 경우는 (200)면이 경도가 제일 높은데 (200)면에서 성장한 것을 확인 할 수 있었다. 잔류가스 분석 결과로는 일정한 Ar의 유량을 흘렸을 때 $N_2$의 변화량이 비례적인 경향이 보이는 것을 확인 할수 있었다. 또한 $N_2$가 흐르면서도 유도 결합 플라즈마를 이용한 스퍼터-승화 증착 시스템을 사용하면 일정한 공정을 하는 것을 확인 할 수 있었다. 질소의 분압이 유량에 따라서 $3.0{\times}10^{-10}$ Torr에서 $1.65{\times}10^{-9} $Torr까지 일정한 비율로 증가한다. 즉, 이 시스템으로 양산장비 설계를 하여도 가능 하다는 것을 말해준다.

  • PDF

Decomposition of Ethylene by Using Dielectric Barrier Discharge Plasma (유전체 배리어 방전 플라즈마를 이용한 에틸렌의 분해)

  • Jang, Doo Il;Lim, Tae Hun;Lee, Sang Baek;Mok, Young Sun;Park, Hoeman
    • Applied Chemistry for Engineering
    • /
    • v.23 no.6
    • /
    • pp.608-613
    • /
    • 2012
  • Dielectric barrier discharge plasma reactor was applied to the removal of ethylene from a simulated storage facility ($1.0m^3$) of fruits and vegetables. The system operated in a closed-loop mode by feeding the contaminated gas to the plasma reactor and recirculating the treated gas back to the storage facility. The experiments were carried out with parameters such as discharge power, circulation flow rate, initial ethylene concentration and treatment time. The rate of ethylene decomposition was mainly controlled by the discharge power and the treatment time. With the other conditions kept constant, the ethylene decomposition rate in the presence of the manganese oxide ozone control catalyst installed downstream from the plasma reactor was lower than that in the absence of it. The suggests that unreacted ozone from the plasma reactor accumulated in the storage facility where it additionally decomposed ethylene. On the basis of an initial ethylene concentration of 50 ppm, the energy requirement for completing the decomposition was about 60 kJ.

A study on Perpendicularity multipoint mode GPS electron floater system of measuring flow velocity (연직 다 지점 GPS 전자플로터 시스템 유속 측정 장치 개발 및 연구)

  • Lee, Jeong Min;Ku, Tae Geom;Kim, Young Do;Seo, Il Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.61-61
    • /
    • 2018
  • 본 연구에서는 전자 플로터 시스템의 관한 것으로, 특히 수표면 위에서 작용하는 바람, 파도 등의 영향을 거의 받지 않으면서 물의 흐름방향에 순응하여 이동할 수 있도록 함으로써 정확한 유속 측정이 가능하도록 한 연직 다 지점 GPS 전자 플로터 시스템 및 이를 이용한 유속 측정방법을 제시하였다. 일반적으로 대기나 해양, 하천 등에서 유동 유체의 유동상태를 파악하기 위하여 다양한 연구가 진행되고 있다. 이 같은 연구에서 유체의 유동 특성을 파악하기 위해 시뮬레이션을 통한 모델링을 하는 것이 한 방법이나, 이는 실제 유체가 유동하는 환경에서 발생되는 요인들을 나타내기 위해서는 한계가 있기 때문에 실제 측정을 통한 검증만큼 실제적이진 못하였다. 본 연구의 유속 측정 장치는 GPS 수신기를 탑재한 GPS 전자플로터가 수표면에 부유하고 라인으로 연결된 수중 추진부인 가이드볼, 중량보강부재로 구성되어져 있다. 기존 연구의 GPS 전자플로터는 1구형으로 표면유속만 측정 할 수 있었고 바람, 파도와 같은 외부영향에 대한 단점이 있었다. 이를 보완하기 위해 연직 다 지점 GPS 전자 플로터를 개발하였으며 이는 수표면 위에서 가해지는 바람, 파도 등의 영향을 거의 받지 않고, 하측에서 지지해주는 가이드볼이 물의 흐름에 의해 자연스럽게 자전할 수 있도록 구성되어져 보다 원활하게 물의 흐름에 순응하여 이동하고 수심에 따라 가이드볼 개수를 조절할 수 있기 때문에 대하천에서 운용이 가능하다. 이러한 유속 측정 장치 개발은 접근의 위험성과 안정성이라는 장점을 가지고 있으며 대하천 및 중소하천에서도 다양하게 운용이 가능하다. 또한 화학유출사고와 같은 문제가 많이 발생하는 요즘 화학사고와 관련된 연구들에 많은 도움이 될 것으로 사료된다.

  • PDF

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance (제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가)

  • Lee, Yeon-Gun;Heo, Jaehyeok;Lee, Dong-Won;Hyun, Myung-Taek
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.70-79
    • /
    • 2018
  • A heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO was constructed with the capacity of 300 RT to supply cool or hot water to greenhouse facilities located 3 km from the power station. The way of transporting heat from the thermal effluent to greenhouses at a long distance was optimized, and a monitoring system to measure the water temperature and detect a leakage in a pipe conduit was also installed. This paper presents the system configuration of the constructed heat pump system for air conditioning and heating of greenhouse facilities in Jeju, and the characteristics of major components deployed in the system. The preoperational tests of the heat pump system were conducted during the summer season in 2018 for evaluation of its cooling performance. The operational stability and cooling performance of the heat pump system were confirmed by investigating the measured fluid temperature and flow rate, and COP of the heat pump in a cooling mode.

Simultaneous Quantitative Determination of Nine Hallucinogenic NBOMe Derivatives in Human Plasma Using Liquid Chromatography Tandem Mass Spectrometry

  • Seo, Hyewon;Yoo, Hye Hyun;Kim, Young-Hoon;Hong, Jin;Sheen, Yhun Yhong
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.18-26
    • /
    • 2019
  • We developed a bioanalytical method for simultaneous determination of nine NBOMe derivatives (25H-NBOMe, 25B-NBOMe, 25E-NBOMe, 25N-NBOMe, 25C-NBOH, 25I-NBOH, 25B-NBF, 25C-NBF, and 25I-NBF) in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS). Human plasma samples were pre-treated using solid-phase extraction. Separation was achieved on a C18 column under gradient elution using a mobile phase containing 0.1% formic acid in acetonitrile and 0.1% formic acid in water at a flow rate of 0.3 mL/min. Mass detection was performed in the positive ion mode using multiple reaction monitoring. The calibration range was 1-100 ng/mL for all quantitative analytes, with a correlation coefficient greater than 0.99. The intra- and inter-day precision and accuracy varied from 0.85 to 6.92% and from 90.19 to 108.69%, respectively. The recovery ranged from 86.36 to 118.52%, and the matrix effects ranged from 27.09 to 99.72%. The stability was acceptable in various conditions. The LC-MS/MS method was validated for linearity, accuracy, precision, matrix effects, recovery and stability in accordance with the FDA guidance. The proposed method is suitable for reliable and robust routine screening and analysis of nine NBOMe derivatives in forensic field.

Failure characteristics and mechanical mechanism of study on red sandstone with combined defects

  • Chen, Bing;Xia, Zhiguo;Xu, Yadong;Liu, Shuai;Liu, Xingzong
    • Geomechanics and Engineering
    • /
    • v.24 no.2
    • /
    • pp.179-191
    • /
    • 2021
  • In this study, the strength and failure mechanism of red sandstones with combined defects were investigated by uniaxial compression tests on red sandstones with different crack angles using two-dimensional particle flow code numerical software, and their mechanical parameters and failure process were studied and analyzed. The results showed that the mechanical characteristics such as peak strength, peak strain, and elastic modulus of the samples with prefabricated combined defects were significantly inferior than those of the intact samples. With increasing crack angle from 15° to 60°, the weakening area of cracks increased, elastic modulus, peak strength, and peak strain gradually reduced, the total number of cracks increased, and more strain energy was released. In addition, the samples underwent initial brittle failure to plastic failure stage, and the failure form was more significant, leading to peeling phenomenon. However, with increasing crack angle from 75° to 90°, the crack-hole combination shared the stress concentration at the tip of the crack-crack combination, resulted in a gradual increase in elastic modulus, peak strain and peak strength, but a decrease in the number of total cracks, the release of strain energy reduced, the plastic failure state weakened, and the spalling phenomenon slowed down. On this basis, the samples with 30° and 45° crack-crack combination were selected for further experimental investigation. Through comparative analysis between the experimental and simulation results, the failure strength and final failure mode with cracks propagation of samples were found to be relatively similar.

Study on Prediction of Net Thrust of Multi-Pod-Driven Ice-Breaking Vessel Under Bollard Pull and Overload Conditions According to the Change of Water Depth Using Computational Fluid Dynamics-Based Simulations (수심 변화에 따른 볼라드 당김 및 과부하 조건에서의 다중 포드 추진 쇄빙선박의 여유추력 추정에 대한 수치해석적 연구)

  • Kim, JinKyu;Kim, Hyoung-Tae;Kim, Hee-Taek;Lee, Hee-Dong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.3
    • /
    • pp.158-166
    • /
    • 2021
  • In this paper, a numerical analysis technique using a body force model is investigated to estimate the available net thrust of multi-pod-driven ice-breaking vessels under bollard pull and overload conditions. To employ the body force model in present flow simulations, drag and thrust components acting on the pod unit are calculated by using Propeller Open Water (POW) test data. The available net thrusts according to the direction of operation are evaluated in both bollard pull and overload conditions under deep water. The simulation results are compared with the model test data. The available net thrusts, calculated by the present analysis for ahead operating modes at 3~6 knots which are typical speeds of the target vessel in arctic field, are agreed well with the model test results. It is also found that the present result for astern operating mode appears approximately 6 % larger than the model test result. In addition, the available net thrusts are calculated under the both operating conditions accompanied by shallow water effects, and the main cause of the difference is studied. Based on the result of the present study, it is confirmed that the body force model can be applied to the performance evaluation of multi-pod propulsion system and the main engine selection in early design stage of the vessel.