The Effect of Jeongcheonhwadam-tang on Peak Expiratory Flow in Chronic Pulmonary Disease Patient with Dyspnea (호흡곤란을 동반한 만성호흡기질환 환자에서 정천화담탕이 최고호기유속에 미치는 영향(影響))

  • Heo, Tae-Yool;Im, Jae-Hyung;Park, Dong-Il
    • The Journal of Internal Korean Medicine
    • /
    • 제26권4호
    • /
    • pp.875-880
    • /
    • 2005
  • Object : Dyspnea is a one of the common symptom in pulmonary disease. Jungchunghwadam-tang was used to treat chronic pulmonary disease patients with dyspnea. Thus in this study we evaluate the effect of Jungchunghwadam-tang on dyspnea. Methods : In this study, ten chronic pulmonary disease patients were treated with Jungchunghwadam-tang. Peak expiratory flow were obtained by peak flow meter. Result : After the treatment, peak expiratory flow was increased significantly compared with before treatment. Percentage of predict peak expiratory flow was also increased significantly compared with before treatment. Conclusion : The result of this study demonstrate that Jungchunghwadam-tang taken for dyspnea on chronic pulmonary disease are effective. Further investigation in well designed follow up study is needed.

  • PDF

A study on the development of CW(Continuous-Wave) Doppler system for measuring bi-directional blood flow information. (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • Kang, Chung-Sin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1239-1242
    • /
    • 1987
  • With the convention CW Doppler velocity meter, bi-directional velocities cannot be separated. The new CW Doppler system usee quadrature detection and phase rotation to Produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, can easily differentiate typical artery flow from vein flow. and measure both velocity characteristics qualitatively.

  • PDF

Optimal Gas-Flow Conditions for Stabilization of Lean-Burn Combustion (희박연소 안정화를 위한 가스유동장 조건에 관한 연구)

  • 이기형;이창식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제19권3호
    • /
    • pp.763-770
    • /
    • 1995
  • Gas flow characteristics within the cylinder is important factors in impoving lean combustion stability. This paper shows the effects of various flow fields generated by a swirl control valve(SCV) on combustion process in a 4-valve spark ignition engine. An impulse swirl/tumble meter was used to elucidation the steady-state flow characteristics, and a rotating grating type LDV was developed to measure the mean velocity and tunbulence intensity in relation to the crank angle. These methodologies were applied to clarify the correlation between gas flow characteristics and combustion stability at a lean air fuel ratio. An analysis of the correlation revealed the gas flow conditions required to optimize a lean-burn system.

Evaluation of Flow Measurement Uncertainty of Sonic Nozzle (소닉노즐의 유량측정 불확도 평가)

  • Choe, Hae-Man;Park, Gyeong-Am;Choe, Yong-Mun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제25권12호
    • /
    • pp.1898-1904
    • /
    • 2001
  • Measurement uncertainty should be evaluated according to ISO/IEC 17025. In Flow measurement area, uncertainty evaluation scheme was applied to the reference flow meter, sonic nozzle. Uncertainty was calculated by evaluating various uncertainty factors affected in flow measurement. The expanded uncertainty(U) of the sonic nozzle was 2.1$\times$ 10$^{-3}$ (confidence level of 95 %). This evaluation example will be useful in flow measurement uncertainty determination of other flow meters.

A Study on the Flow Characteristics of the Intake Port and Cylinder Generated by a Tumble Intensifying Valve (텀블강화형 밸브에 의한 흡기포트 및 실린더내의 유동 특성에 관한 연구)

  • 이기형;이창식;정재우;전문수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제5권2호
    • /
    • pp.183-196
    • /
    • 1997
  • Gas flow field within the cylinder which is called a tumble flow is important factor in improving lean combustion stability. In this study, steady state flow tests were performed to quantify tumble ratio of flowfields generated by a tumble intensifying valve(TIV). In addition, velocity and fluctuation profiles in an intake port and flowfields in th cylinder were inspected using a hotwire anemometer and a laser light sheet method with various TIV configurations. These experimental results show that installated TIV has a great effect on flow field distribution in an intake port and test effects enhance a tumble flow in the cylinder.

  • PDF

Development of automatic flow control system based on LabView (LabView를 이용한 자동유량제어 시스템의 개발)

  • Kang, Tae-Won;Kim, Du-Seob;Ann, Sung-Gyu
    • Journal of Engineering Education Research
    • /
    • 제19권2호
    • /
    • pp.3-7
    • /
    • 2016
  • A flow control system was designed and fabricated to control the flow rate of liquid through the pipe. This control system was composed of hardwares and software, hardwares as controller, gate valve, orifice meter and data aquisition board and software as National instruments Labview program. Control of flow rate was executed by adjusting the pneumatic valve located at the center of pipe line based on the control signal generated by LabView PID control algorithm, which converts analog signal measured by pressure difference of orifice to digital signal to adjust pneumatic valve. For the controller setup Ziegler-Nichols tuning technique was applied and control performances were investigated for not only the disturbance but also the set point changes. Developed system showed good control performances in flow control enough to use as teaching tool of feedback control theory and practice in university, and also as industrial application.

Flow Visualization Using Thin Oil-Film in the Flow Control of Shock Wave/Turbulent Boundary-Layer Interactions (충격파와 경계층 간섭유동 제어에서 오일막을 이용한 유동가시화)

  • Lee Yeol
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.117-120
    • /
    • 2002
  • An experimental research has been carried out for flow control of the shock wave/turbulent boundary-layer interaction utilizing aeroelastic mesoflaps. Various shapes and thicknesses of the mesoflap are tested to achieve different deflections of the flap, and ail the results are compared to the solid-wall reference case without flow-control mechanism. Quantitative variation of skin friction has been measured downstream of the interactions using the laser interferometer skin friction meter, and qualitative skin friction distribution has been obtained by observing the interference fringe pattern on the oil-film surface. A strong spanwise variation in the fringe patterns with a narrow region of separation near the centerline is noticed to form behind the shock structure, which phenomenon is presumed partially related to three-dimensional flow structures associated with both the sidewalls and the bottom test surface. The effect of the shape of the cavity is also observed and it is noticed that the shape of the cavity is not negligible.

  • PDF

Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid (압축성유체 유량계측장치 설계 및 제작)

  • Ji, S.W.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • 제10권4호
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.

Design and Fabrication of a Surge Impedance Meter (서지임피던스 측정기의 설계 및 제작)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Kim, Il-Kwon;Moon, Byung-Doo;Kim, Hwang-Kuk;Park, Chan-Yong
    • Journal of the Korean Society for Railway
    • /
    • 제10권6호
    • /
    • pp.645-649
    • /
    • 2007
  • Ground systems flow fault currents into the ground, and suppress Ground Potential Rise (GPR) by the current. In this paper, we designed and fabricated a surge impedance meter to analyze the ground impedance in wide frequency ranges. The meter consists of a surge generator, a high speed sample/hold (S/H) circuit and an associated electronics. The surge generator produces surge voltage up to 5kV in ranges of $50\sim500ns$. Field tests were carried out to evaluate the surge impedance meter at a driven-rod ground system. The results showed that surge impedance of ground systems should be measured by various fast surge waveforms, since the impedance increases as the rise time of applied voltage increases.

Groundwater Flow Modeling and Suggestion for Pumping Rate Restriction around K-1 Oil Stockpiling Base with Geological Consideration (지질조건을 고려한 K-1 비축기지 주변의 지하수 모델링과 양수량 제한구역 제안)

  • Moon, Sang-Ho;Kim, Kue-Young;Ha, Kyoo-Chul;Kim, Young-Seog;Won, Chong-Ho;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • 제20권2호
    • /
    • pp.169-181
    • /
    • 2010
  • This study aimed at simulating several responses to stresses caused by the ground water level variations around the K-1 oil stockpile. For this simulation, we considered the characteristic hydrogeological condition including the special occurrence of long and thick acidic dyke, which is regarded as the main geological structure dominating the ground water flow system at this study area. We activated twenty-four imaginary wells which are located in northern and southern area around central K-1 site. Each neighboring distance is altogether 300 m and whole distance between K-1 site and remote wells is 1,200 m. Through the modeling, we operated the long-term and continuous pumping tests and finally categorized five zones based on maximum pumping rates for the imaginary wells; zone I within 300 meter distance from K-1 site with a pumping rate of 50 $m^3/day$; zone II between 300 to 600 meter distance from K-1 site with a pumping rate of 75 $m^3/day$; zone III between 600 to 900 meter distance from K-1 site with 150 $m^3/day$; zone IV between 900 to 1,200 meter distance from K-1 site with 300 $m^3/day$; and zone V of acidic dyke area. At zone V, especially because of their possibility of high transmissivity for groundwater flow, it is necessary to control and restrict groundwater discharge.