STABILITY ANALYSIS OF BURSTING MODELS

  • Lee, Eui-Woo
    • 대한수학회지
    • /
    • 제42권4호
    • /
    • pp.827-845
    • /
    • 2005
  • In this paper, we present a general method for the stability analysis of some bursting models. Our method is geometric in the sense that we consider a flow-defined return map defined on a section and determine when the map is a contraction. We find that there are three different stability types in the codimension-1 planar bursters.

모형 연소실에서 분사기 연소 안정성 평가에 관한 실험적 연구 (A Experimental Study on Combustion-Stability Rating in a Subscale Chamber)

  • 김철진;손채훈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.77-78
    • /
    • 2012
  • To predict combustion instability in actual full-scale combustion chamber of rocket engines, air-injection test is proposed with scaling techniques. From the data, damping factors have been obtained as a function of hydraulic parameter and the data give us instability map. Two instability regions are presented and it is found that they coincide reasonably with them from hot-fire test with full-scale flow rates. Accordingly, the proposed approach can be applied cost-effectively to stability rating of jet injectors when mixing of fuel and oxidizer jets is the dominant process in instability triggering.

  • PDF

회화적 애니메이션에서 브러시 스트로크의 시간적 일관성을 유지하기 위한 모션 맵 생성 (Motion Map Generation for Maintaining the Temporal Coherence of Brush Strokes in the Painterly Animation)

  • 박영섭;윤경현
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제33권8호
    • /
    • pp.536-546
    • /
    • 2006
  • 회화적 애니메이션은 비디오 동영상을 이용하여 손으로 그린 듯 한 회화적 느낌을 표현하는 방법이며 프레임 간 브러시 스트로크의 시간적 일관성을 유지하는 것이 가장 중요한 요소이다. 본 논문에서는 프레임 간 브러시 스트로크의 일관성을 유지하기 위한 모션 맵 생성을 제안한다. 모션 맵이란 모션이 발생한 에지 위치를 기준으로 해서 모션 정보를 더함으로써 프레임 간 에지가 움직이는 영역을 말한다. 본 논문에서 사용한 모션 추정 방법은 광류 (optical flow) 방법과 블록 기반 방법을 이용하였으며 여러 가지 모션 추정 방법을 통해서 얻은 모션 정보 ( 방향과 크기 ) 중 신호 대 잡음비 (PSNR)가 가장 큰 방법을 최종 모션 정보로 선택하여 모션 맵을 생성하였다. 생성된 모션 맵은 다음 프레임의 덧칠 부분을 결정해 준다. 손으로 그린 듯 한 회화적 느낌을 표현하면서도 프레임 간 브러시 스트로크의 시간적 일관성을 유지하기 위해서 브러시 스트로크의 방향을 결정해주는 강한 에지에 대해서만 모션 정보를 적용하였다. 또한 다중노출기법과 소스 영상과 캔버스간의 차이 맵을 이용하여 프레임 간 플릭커링 현상을 줄이고자 하였다. 구조적 일관성을 유지하기 위해 국부 기울기 보간법 (local gradient interpolation)을 이용하여 브러시 스트로크 간 방향의 일관성을 유지하였다.

회전식 화학증착 장치 내부의 유동해석을 통한 최적 유량 평가 (COMPUTATIONAL ASSESSEMENT OF OPTIMAL FLOW RATE FOR STABLE FLOW IN A VERTICAL ROTATING DISk CHEMICAL VAPOR DEPOSITION REACTOR)

  • 곽호상
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.86-93
    • /
    • 2012
  • A numerical investigation is conducted to search for the optimal flow rate for a rotating-disk chemical vapor decomposition reactor operating at a high temperature and a low pressure. The flow of a gas mixture supplied into the reactor is modeled by a laminar flow of an ideal gas obeying the kinetic theory. The axisymmetric two-dimensional flow in the reactor is simulated by employing a CFD package FLUENT. With operating pressure and temperature fixed, numerical computations are performed by varying rotation rate and flow rate. Examination of the structures of flow and thermal fields leads to a flow regime diagram illustrating that there are a stable plug-like flow regime and a few unfavorable flow regimes induced by mass unbalance or buoyancy. The criterion for sustaining a plug-like flow regime is discussed based on a theoretical scaling argument. Interpretation of the flow regime map suggests that a favorable flow is attainable with a minimum flow rate at the smallest rotation rate guaranteeing the dominance of rotation effects over buoyancy.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제3권4호
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

고분자 전해질 연료전지 가시화 장치를 이용한 이상유동 현상 관찰 (Visualization of two-phae flow by using transparent Proton Exchange Membrane Fuel Cell)

  • 이동율;배중면
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.374-377
    • /
    • 2009
  • The operating temperature of Proton Exchange Membrane Fuel Cell (PEMFC) usually has to be limited under $100^{\circ}C$ to maintain the proper ionic conductivity. Therefore, the only product from reaction, water, is in the liquid phase. Two-phase flow makes the flow phenomenon in the channel difficult to understand and predict. Water blocking in the PEMFC channel or the pore of Gas Diffusion Layer (GDL), called flooding, is known as the main effect of PEMFC degradation. To analyze two-phase flow, the PEMFC with transparent acrylic plate was used. Two-phase flow patterns were observed by varying the current density. When the PEMFC is mounted horizontally, water in the cathode is mainly transported on the interface between the channel and GDL.

  • PDF

통계적 접근법에 의한 불연속암반의 지하수 유동해석 (Groundwaterflow analysis of discontinuous rock mass with probabilistic approach)

  • 장현익;장근무;이정인
    • 터널과지하공간
    • /
    • 제6권1호
    • /
    • pp.30-38
    • /
    • 1996
  • A two dimensional analysis program for groundwater flow in fractured network was developed to analyze the influence of discontinuity characteristics on groundwater flow. This program involves the generation of discontinuities and also connectivity analysis. The discontinuities were generated by the probabilistic density function(P.D.F.) reflecting the characteristics of discontinuities. And the fracture network model was completed through the connectivity analysis. This program also involves the analysis of groundwater flow through the discontinuity network. The result of numerical experiment shows that the equivalent hydraulic conductivity increased and became closer to isotropic as the density and trace length increased. And hydraulic head decreased along the fracture zone because of much water-flow. The grouting increased the groundwater head around cavern. An analysis of groundwater flow through discontinuity network was performed around underground oil storage cavern which is now under construction. The probabilistic density functions(P.D.F) were obtained from the investigation of the discontinuity trace map. When the anisotropic hydraulic conductivity is used, the flow rate into the cavern was below the acceptable value to maintain the hydraulic containment. But when the isotropic hydraulic conductivity is used, the flow rate was above the acceptable value.

  • PDF

부력을 최소화한 대향류 확산화염 소화거동에서 연료농도구배의 영향 (Influence of Fuel concentration gradient on the Extinction Behavior in Buoyancy minimized Counterflow Diffusion Flame)

  • 박진욱;박정;윤진한;길상인
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.379-381
    • /
    • 2014
  • Influence of fuel concentration gradient was investigated near flame extinction limit in buoyancy-suppressed non-premixed counterflow flame with triple co-flow burner. The use of He curtain flow produced a microgravity level of $10^{-2}-10^{-3}g$ in He-diluted non-premixed counter triple co-flow flame experiments. Flame stability map was presented based on flame extinction and oscillation near extinction limit. The stability map via critical diluent mole fraction with global strain rate was represented by varying outer and inner He-diluted mole fractions. The flame extinction modes could be classified into five: an extinction through the shrinkage of the outmost edge flame forward the flame center with and without self-excitation, respectively ((I) and (II)), an extinction via the rapid expansion of a flame hole while the outmost edge flame is stationary (III), both the outermost and the center edge flames oscillate, and then a donut shaped flame is formed or the flame is entirely extinguished (IV), a shrinkage of the outermost edge flame without self-excitation followed by shrinking or sustain the inner flame (V).

  • PDF

낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석 (Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF