• 제목/요약/키워드: flow limitation

검색결과 373건 처리시간 0.041초

SDN 플로우 테이블 제한에 따른 리소스 어택 (Resource Attack Based On Flow Table Limitation in SDN)

  • 뉴엔 트리 투안 힙;김경백
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2014년도 추계학술발표대회
    • /
    • pp.215-217
    • /
    • 2014
  • In Software Defined Network (SDN), data plane and control plane are decoupled. Dummy switches on the data plane simply forward packet based on the flow entries that are stored in its flow table. The flow entries are generated by a centralized controller that acts as a brain of the network. However, the size of flow table is limited and it can conduct a security issue related to Distributed Denial of Service (DDoS). Especially, it related to resource attack that consumes all flow table resource and consumes controller resources. In this paper, we will analyze the impact of flow table limitation to the controller. Then we propose an approach that is called Flow Table Management to handle flow table limitation.

Flow limitation이 일어나는 기도내 위치의 실험적 측정 (Experimental Localization of flow Limiting Segment)

  • 차은종;이태수
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권3호
    • /
    • pp.209-216
    • /
    • 1992
  • A new experimental technique is proposed to localize the flow limiting segment(FLS) during forced expiration. The present technique is based on the pressure drip across FLS and a consequent change in airway resistance, which can provide an accurate and objective location of FLS. During forced expiratory maneuver artificially induced by a strong negative pressure (-100mmHg) applied at the trachea in an anesthetized open chest dog, airway resistance( R) was calculated from air flow and airway pres- sure signals at various airway locations and lung volumes, At the lung volumes above 10 % VC, FLS located in the trachea 6cm lower from the larynx. With the lung volume decreased below 8% VC, FLS jumped upstream to End-3rd generation of the airway. These results were similar with the previous reports from excised dog lungs, which demonstrated the validity of the present technique. Since the present technique provides a more objective measure of FLS location, it would be useful in future studies of expiratory flow limitation.

  • PDF

유연 혈관에서 유체-고체 상호작용에 대한 유한요소 해석 (Finite element analysis of the fluid-structure interaction in a compliant vessel)

  • 심은보;고형종
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.591-596
    • /
    • 2000
  • Flow through compliant tubes with linear taper in wall thickness is numerically simulated by finite element analysis. Two models are examined: a planar two-dimensional channel, and an axisymmetric tube. For verification of the numerical method, flow through a compliant stenotic vessel is simulated and compared to existing experimental data. Computational results for an axisymmetric tube show that as cross-sectional area falls with a reduction in downstream pressure, flow rate increases and reaches a maximum when the speed index (mean velocity divided by wave speed) is near unity at the point of minimum cross-section area, indicative of wave speed flow limitation or "choking" (flow speed equals wave speed) in previous one-dimensional studies. For further reductions in downstream pressure, flow rate decreases. Cross-sectional narrowing is significant but localized. When the ratio of downstream-to-upstream wall thickness is ${\le}$ 2 the area throat is located near the downstream end; as wall taper is increased to ${\ge}$ 3 the constriction moves to the upstream end of the tube. In the planar two-dimensional channel, area reduction and flow limitation are also observed when outlet pressure is decreased. In contrast to the axisymmetric case, however, the elastic wall in the two-dimensional channel forms a smooth concave surface with the area throat located near the mid-point of the elastic wall. Though flow rate reaches a maximum and then falls, the flow does not appear to be choked.

  • PDF

협소 사각유로에서 공기-물 대향류 유동한계 (Air-water Countercurrent Flow Limitation in Narrow Rectangular Channels)

  • 김병주
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.441-446
    • /
    • 2007
  • An experimental study on the countercurrent two-phase flow in narrow rectangular channels has been peformed. Countercurrent flow limitation (CCFL) was investigated using air and water in 760mm long, 100mm wide, vertical test sections with 1 and 3mm channel gaps. Tests were systematically performed with downward liquid superficial velocities and upward gas velocities covering 0 to 0.125 and 0 to 3.5m/s ranges, respectively. As the gap width of rectangular channel increased the CCFL water superficial velocity decreased for the given air superficial velocity. Slight increase of the air superficial velocity resulted in the abrupt decrease of water velocity when $j_g=2{\sim}4m/s$. The critical superficial velocity of air, at which the downward flow of water was no longer allowed, also decreased with the increase of gap width. The experimental results were compared with the previous correlations, which were mainly for round tubes, and the qualitative trends were found to be partially acceptable. However the quantitative discrepancies were hardly neglected. New correlation of CCFL was developed and showed good agreement with the experimental data.

폐수특성 및 처리기술에 근거한 산업폐수 배출허용기준 설정체계 연구 (Establishment of Effluent Limitation based on Wastewater Characteristics and Treatment Technology)

  • 권오상;정진영;허태영;전항배;이연희;박상민
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.804-812
    • /
    • 2012
  • This study contemplated domestic and other country's effluent limitation standards and suggested a methodology to establish technology-base limitation value. Current effluent limitation regulates industrial point sources discriminated by discharge flow rate and by regional distinction in Korea. Discharged $BOD_5$ load from large-scale plants(flow rate above $2,000\;m^3/day)$ exceeds 50% of overall industrial wastewater, which present rationale for discrimination based on plant size. However, regional distinction and pollutant- specific regulation might be insufficient to meet practical effectiveness of wastewater management policy, due to the nearly same limitation. Water quality data and treatment methods were investigated in hospital industry. And their distribution of effluent $BOD_5$ concentrations was statistically analyzed to suggest limitation value. Effluent $BOD_5$ concentrations showed lognormal distribution and $95^{th}$ percentile was corresponded to 87.9 mg/L, which could be suggested as tentative effluent limitation in hospital industry. The $95^{th}$ percentile of log-transformed distribution showed similar value of 86.5 mg/L. This study demonstrated reasonable methodology for establishing effluent limitation reflecting wastewater characteristic and treatment technology in separately categorized industry.

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

벽-유체의 상호작용을 고려한 유연관 내부 유동의 수치적 연구 (Numerical Analysis of the Flow in a Compliant Tube Considering Fluid-wall Interaction)

  • 심은보
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.391-401
    • /
    • 2000
  • 본 연구에서는 정맥 등과 같은 혈관의 상황을 모사하기 위하여 선형적으로 벽 두께가 변하는 축 대칭 관의 벽면과 유동의 상호작용을 유한요소 방법으로 해석하였다. 사용한 유한요소 상용 소프트웨어(ADINA)의 타당성을 검증하기 위해서 막힘이 있는 혈관에서의 벽과 혈류의 상호작용을 해석하고 이를 기존의 실험결과와 비교하였다. 또한 2차원 신축 벽을 가지는 평판 사이의 유체 유동에 대한 결과를 기존 연구결과와 비교하였다. 축대칭 문제의 경우, 입구의 압력은 일정하게 유지하면서 출구 압력을 감소시켜 나간다. 출구 압력의 감소에 따라, 유량은 증가하며, 관내 유로의 단면적은 감소한다. speed index(평균속도를 파의 속도로 나눈 값)가 1 근방에서 유량은 최대가 되며, 유로 단면적이 최소가 된다. 그리고 출구압력이 좀 더 감소하면 유량은 오히려 줄어든다. 이와 같은 현상을 유동제한(flow limitation) 혹은 초킹(choking)이라 하는데, 폐의 기도(airway) 및 모세혈관, 그리고 이외의 여러 정맥들에서 자주 발생하는 폭포효과의 원인이 된다. 상류벽 두께와 하류 벽두께의 비가 2 일 경우에는 하류쪽에서 목(area throat)이 형성되며 이 비가 3일 경우에는 상류 쪽으로 이동하는데 하류 벽면의 강성(stiffness)이 상류 쪽에 비해 강하게 되어서 상류 쪽에서 먼저 붕괴가 일어나기 때문이다.

  • PDF

그루브형 태양열 집열용 히트파이프의 열성능 해석 (Analysis for Thermal Performance of Axially Grooved Heat Pipe for Solar Collector)

  • 홍정규;서정세;변길성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2123-2128
    • /
    • 2004
  • In this study, analysis is made for the effects of groove shape on the thermal performance of a axial groove heat pipe. The mathematical models of two-phase flow in grooved heat pipe are presented for the capillary limitation in steady state. Generally, the heat pipe performance depends on the capillary pressure and liquid flow. The friction force of liquid flow through the groove increases with the groove width decreased, and then the capillary pressure is improved in the gas-liquid interface of groove. Therefore, the optimal groove width shaper exists for the maximum thermal performance of heat pipe. In this paper, the optimal groove shape and scale are presented by considering both capillary pressure and liquid flow.

  • PDF

Theoretical Analysis of Heat Transport Limitation in a Screen Mesh Wick Heat Pipe

  • Lee, Ki-Woo;Park, Ki-Ho;Lee, Wook-Hyun;Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2004
  • The purpose of the present study is to examine the heat transport limitations in a screen mesh heat pipe for electronic cooling by theoretical analysis. Diameter of pipe was 6mm, and mesh numbers were 50, 100, 150, 200 and 250, and water was investigated as working fluid. According to the change of mesh number, wick layer, inclination and saturation temperature, the maximum heat transport limitations by capillary, entraintment, sonic and boiling were analyzed by a theoretical design method of heat pipe, including capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, etc. Based on the results, the capillary limitation in a small diameter of heat pipe is largely affected by mesh number and wick layer. Mesh number of 250 is desirable not to be used in pipe diameter of 6 mm, because capillary heat transport limitation decreases by the abrupt increase of liquid friction pressure due to the small liquid flow area. For the heat transport of 15 watt in 6mm diameter pipe, mesh number of 100 and one layer is an optimum wick condition, which thermal resistance is the smallest.

AN EXPERIMENTAL STUDY ON AIR-WATER COUNTERCURRENT FLOW LIMITATION IN THE UPPER PLENUM WITH A MULTI-HOLE PLATE

  • NO HEE CHEON;LEE KYUNG-WON;SONG CHUL-HWA
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.557-564
    • /
    • 2005
  • Air-water countercurrent flow limitation at perforated plates with four holes was investigated in a vertical tank to see the effects of the plate thickness, the number of hole, and the diameter of the hole on the onset of CCFL. The thickness of plates was 1 cm and 4 cm, with a relatively large hole diameter of 5 cm. The collapsed water level formed on the perforated plate and its distribution in the upper plenum were measured. The gas flow rate in the multi-hole plate is relatively higher than one in the single tube because some of holes in the multi-hole plate provide a flow path fur liquid with less air-liquid resistance than in the single tube. The onset of CCFL occurred at nearly the same air flow rate regardless of the plate thickness. The negligible effect of the plate thickness on CCFL means that the flooding is initiated at the top of the plate rather than at its bottom. It turns out that $j_k$ and $K_k$ better fit the data than $H_k$ when hole diameter is greater than 2.86 cm. In our experimental ranges, the collapsed water levels at the onset of CCFL ranged from 7.5 cm to 10.5 cm. There was no three dimensional distribution of water level before and after the onset of CCFL.