• 제목/요약/키워드: flow level

검색결과 4,356건 처리시간 0.033초

압축가스 방출 유압시스템 해석 및 제어 (The Analysis and Control of Compressed Gas Discharging System)

  • 장웅락;김정관;한명철;정찬희;박인기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.458-462
    • /
    • 2004
  • The hydraulic system for discharging compressed gas is composed of compressor tank, proportional flow control servo valve, expulsion spool valve and discharging tube. Purpose of this study is to control of expulsion spool valve. First, we analyzed the hydraulic system. The flow control servo valve is modeled as a 2nd order transfer function and friction force of the expulsion spool valve is modeled as nonlinear model with stribeck effect. However, it is difficult to include the flow reaction force in modeling. So, we exchanged from the simplified flow reaction force of the compressed gas affection into the flow analysis code written in FORTRAN code. Our simulation of the oil pressure system for discharging gas used MATLAB/Simulink. So, we realized 'Level -2 S-Function Fortran' to cooperate for MATLAB/Simulink and FORTRAN code. PD controller is selected to control in this system. Simulation results show that with given conditions the controllers give a good tracking performance.

  • PDF

A Fair Scalable Inter-Domain TCP Marker for Multiple Domain DiffServ Networks

  • Hur, Kyeong;Eom, Doo-Seop
    • Journal of Communications and Networks
    • /
    • 제10권3호
    • /
    • pp.338-350
    • /
    • 2008
  • The differentiated services (DiffServ) is proposed to provide packet level service differentiations in a scalable manner. To provide an end-to-end service differentiation to users having a connection over multiple domains, as well as a flow marker, an intermediate marker is necessary at the edge routers, and it should not be operated at a flow level due to a scalability problem. Due to this operation requirement, the intermediate marker has a fairness problem among the transmission control protocol (TCP) flows since TCP flows have intrinsically unfair throughputs due to the TCP's congestion control algorithm. Moreover, it is very difficult to resolve this problem without individual flow state information such as round trip time (RTT) and sending rate of each flow. In this paper, to resolve this TCP fairness problem of an intermediate marker, we propose a fair scalable marker (FSM) as an intermediate marker which works with a source flow three color marker (sf-TCM) operating as a host source marker. The proposed fair scalable marker improves the fairness among the TCP flows with different RTTs without per-flow management. Through the simulations, we show that the FSM can improve TCP fairness as well as link utilization in multiple domain DiffServ networks.

2차원과 3차원 아음속 공동 유동 특성에 대한 수치적 연구 (NUMERICAL ANALYSIS OF TWO- AND THREE-DIMENSIONAL SUBSONIC TURBULENT CAVITY FLOWS)

  • 최홍일;김재수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.187-193
    • /
    • 2007
  • The flight vehicles have cavities such as wheel wells and bomb bays. The flow around a cavity is characterized as unsteady flow because of the formation and dissipation of vortices due to the interaction between the freestream shear layer and cavity internal flow, the generation of shock and expansion waves. Resonance phenomena can damage the structures around the cavity and negatively affect aerodynamic performance and stability. In the present study, numerical analysis was performed for cavity flows by the unsteady compressible three dimensional Reynolds-Averaged Navier-Stokes (RANS) equations with Wilcox's ${\kappa}\;-\;{\omega}$ turbulence model. The cavity has the aspect ratios of 2.5, 3.5 and 4.5 for two-dimensional case, same aspect ratios with the W/D ratio of 2 for three-dimensional case. The Mach and Reynolds numbers are 0.53 and 1,600,000 respectively. The flow field is observed to oscillate in the "shear layer mode" with a feedback mechanism. Based on the SPL(Sound Pressure Level) analysis of the pressure variation at the cavity trailing edge, the dominant frequency was analyzed and compared with the results of Rossiter's formula. The MPI(Message Passing Interface) parallelized code was used for calculations by PC-cluster.

  • PDF

수평흐름에 의한 제방모형내의 비정상침투에 관한 실험적 연구 (An Experimental Study of Non-Steady State Seepage in the Levee Model by Parallel Water Flow)

  • 신방웅;이봉직
    • 대한토목학회논문집
    • /
    • 제14권5호
    • /
    • pp.1253-1263
    • /
    • 1994
  • 수평흐름에 의한 제체내의 비정상침투류를 실험을 통하여 구명한 것으로 흐름의 속도와 수위의 변동에 따른 제체내에서의 침투류영향을 고려하므로써 하천제방의 안정성증대에 목적을 두었다. 실험은 투수계수가 서로 다른 3가지 모델($K_1=3.52{\times}10^{-1}cm/sec$, $K_2=1.94{\times}10^{-1}cm/sec$, $K_3=4.19{\times}10^{-2}cm/sec$)에 대하여, 각기 흐름의 속도를 60, 70, 80, 90 cm/sec로 변화시키고 동시에 수위를 상승 또는 하강시키는 방법으로 제체내에 발생하는 수위변화를 실험을 통하여 분석하였다. 분석결과 제체내의 침투현상은 제체의 투수계수가 크고, 흐름의 속도가 작을수록 유속의 변화에 따른 영향을 많이 받음을 알 수 있으며, 제외지 수위의 상승과 강하에 따른 배면부 및 표면부에서의 수위가 유속의 영향에 따라 변화함을 알 수 있다.

  • PDF

일정 열유속의 하부 가열면을 갖는 채널캐비티 내부유동의 PIV 계측 (PlV Measurement of Channel Cavity Flow with Bottom Heat surface of Constant Heat Flux)

  • 조대환;김진구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.437-442
    • /
    • 1997
  • An experimental study was carried out in a channel cavity with square heat surface by visual¬ization equipment with Mach - Zehnder interferometer and laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two¬frame grey-level cross correlation algorithm. Heat source was uniform heat flux(o.4W/cm$^2$, , O.8W/cm$^2$, 1.2W/cm$^2$). Obtained result showed various flow patterns such as kinetic energy distribution. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach ~ Zehnder are also compared in terms of constant heat flux.

  • PDF

배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험(Ⅱ)- 문비 안에서 밖으로의 흐름 - (Model Tests Study on Flow-induced Vibrationof Tainter Gate in Estuary Sulices(Ⅱ)- Flow from the Gate Inside to the Gate Outside -)

  • 이성행;우상익
    • 한국농공학회논문집
    • /
    • 제46권2호
    • /
    • pp.41-47
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66 m in width, 0.5 m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. In the flow from the gate inside to the gate outside, the amplitudes of the vibration are measured under the different gate opening and downstream water level conditions. Also revised gate models with 20 mm bottom width are tested under the different gate openings and water levels. The results are analyzed to study the characteristics of the Tainter gate vibration in the sea ward flow. These test results are assessed in comparison with the results in the lake ward flow, as a result, presents the dynamic characteristics of the Tainter gate and a basic data for the guide manuals of gate management.

제주도 성산유역의 저투수층 구조에 따른 지하수 흐름 분석 (Analysis on Groundwater Flow According to Low Permeable Layer Structure over Seongsan Watershed of Jeju Island)

  • 김민철;양성기;오승태
    • 한국환경과학회지
    • /
    • 제24권4호
    • /
    • pp.449-459
    • /
    • 2015
  • The depth of low permeable layer in Jeju Island was analyzed using the geologic columnar section data. The highest low permeable layer was found in center of Mt. Halla and the deepest area was in eastern part of Jeju Island. The study area, Seongsan watershed, is located in the eastern part of Jeju where the low permeable layer showing deep in a northward direction. Based on this analysis, the MODFLOW modeling was performed for groundwater flow of Seongsan watershed. The boundary of Seongsan watershed was set up as a no-flow and the modeling result showed the difference -0.26~0.62 m compared to the observed groundwater level. Meanwhile, MODFLOW model results considering low permeable layer showed -0.26~0.36 m differences compared to groundwater level and indicated more accurate than no-flow method result. Therefore, to interpret the groundwater flow over Seongsan watershed, comprehensive consideration including the low permeable layer distribution below the basalt layer is needed.

소득계층별 적자가계의 소비 지출 분석: 2000, 2005, 2010년의 가계를 대상으로 (Analysis of Household Income and Expenditure of Households with a Negative Cash Flow Across Income Groups in 2000, 2005, and 2010)

  • 이종희;양세정
    • 가정과삶의질연구
    • /
    • 제32권5호
    • /
    • pp.125-143
    • /
    • 2014
  • The purpose of this study was to gain a better understanding of households with a negative cash flow. The Household Budget Survey conducted in 2000, 2005, and 2010 by the Bureau of Statistics in South Korea were used for this study. The households used in this study were divided into four groups according to their income levels; they were categorized the lowest, low, middle, and high income groups. This study made several findings regarding households with a negative/positive cash flow. Firstly, the demographic and economic characteristics were different between those who have a negative cash flow and those with a positive cash flow. A female household head, a household head age 65 and older, a household head with a lower educational attainment, an unemployed household head, and the presence of a child/children in schools were related with the household deficit. Secondly, the households with a positive cash flow had a higher income level compared to the households with a negative cash flow, while the households with a negative cash flow had a much higher consumption level compared to the households with a positive cash flow. Thirdly, the household deficit to total income ratio of the lowest income group was higher when compared to any other income group. Lastly, the multivariate statistics showed that households including a child/children in schools are more likely to be a household with a negative cash flow. Especially, the expenditures on education and transportation were related with the likelihood of a household deficit.

횡월류 위어 유입각 변화에 따른 유량계수 추정 기초 연구 (A Study on the Estimation of Discharge Coefficients with Variations of Side Weir Angle)

  • 피완섭;장형준;전계원
    • 한국방재안전학회논문집
    • /
    • 제16권1호
    • /
    • pp.81-89
    • /
    • 2023
  • 최근 이상기후의 영향으로 전 지구적 온난화 및 도시화로 인해 세계적으로 기상이변이 늘어나고 있다. 도시화 및 난개발로 인한 불투수 면적의 증가 같은 문제로 홍수량이 증가함에 따라 홍수피해를 줄이기 위한 다양한 방안이 제시되고 있다. 본 연구에서는 사행하천 구간에 설치되는 횡월류 위어 유입각의 변화에 따라 3차원 CFD 모형인 FLOW-3D를 이용하여 흐름 특성과 월류량을 분석하여 횡월류 위어 유입각에 대한 수공구조물의 월류능력 평가 및 유량계수 산정을 위한 기초 연구를 수행하였다. 분석 결과, 횡월류 위어 유입각이 작을수록 횡월류부 통과 후 주수로 흐름의 수위가 감소하고 유속이 증가하였으며, 유입각이 증가할수록 수위가 상승하였고, 유속이 감소하는 경향을 보였다. 또한, 횡월류 위어 유입각이 40° 이상인 경우 직하류 유속이 상류 유속과 비교하여 감소하는 것을 확인할 수 있었다.

계단식 어도의 난류흐름 수치해석 및 어류 소상 가능성 분석 (Numerical simulations of turbulent flow on the pool and weir type fishway and analysis of ascending possibility of fishes)

  • 권용준;류용욱;김형석
    • 한국수자원학회논문집
    • /
    • 제56권spc1호
    • /
    • pp.1037-1048
    • /
    • 2023
  • 하천에 설치된 댐, 보 등과 같은 횡단구조물은 수생태계에 영향을 미치며 종적 연결성을 단절하기 때문에 어류의 이동을 확보하기 위하여 어도가 설치된다. 그러나 어도 내부의 흐름 특성 및 어종에 따라 어류의 통과효율의 차이가 발생한다. 본 연구에서는 3차원 RANS 모형과 자유수면 해석을 위한 VOF (volume of fluid)기법을 적용한 수치모형을 활용하여 계단식 어도에서 발생하는 난류흐름을 수치모의 하였다. 계단식 어도의 pool의 길이 변화 및 상류 수위 변동을 고려하였으며 이들의 변화에 따라 평균유속 및 난류운동에너지 분포를 분석하였다. 표면류 및 잠입류 특성을 잘 재현하였으며 pool의 길이가 증가하면서 표면류에서 잠입류로 변화하였고 상류 수위가 증가함에 따라 표면류 특성이 명확하게 나타났다. 어도 내 어류의 이동과 관련된 수리학적 인자는 유속 및 난류운동에너지 등이 있으며 이를 바탕으로 어류의 소상 가능성을 검토하였다.