Load Flow Calculation and Short Circuit Faults Transients in Dispersed Generation Systems

  • Hosseini, Seyed Hossein;Shahnia, Farhad;Tizghadam, Saeed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.800-804
    • /
    • 2005
  • Load flow and short circuit fault transients of a power distribution system with wind turbines as dispersed generation units is presented. Usage of renewable energies such as wind is already a small part of total installed power system in medium and low voltage networks. In this paper, a radial power distribution system with wind turbines is simulated using DIgSILENT PowerFactory software for their influence on load flow and short circuit fault transients. Short fault occurring in dispersed generation systems causes some problems for the system and costumers such as fault level increase or the problems of sudden fluctuations in the current, voltage, power and torque of the double fed induction machine utilized in the wind turbines which have been studied and investigated.

  • PDF

Effects of Tumble Adaptor Configurations on the Intake Tumble Characterization (텀블-스월 변환장치 형상이 흡입텀블 특성화에 미치는 영향)

  • Kang, K.Y.;Lee, J.W.;Baek, J.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.5
    • /
    • pp.66-73
    • /
    • 1994
  • The configuration effects of a tumble adaptor which transforms tumble into swirl on the intake tumble characterization under steady flow condition have been investigated by LDV measurement The following parameters were involved to test their effects on tumble-swirl conversion characteristics ; the cylinder height and its bottom shape, measuring position in the swirl induction pipe, and the relative direction of the induction pipe. The short cylinder height and the flat bottom of the tumble adaptor were found effective for the generation of tumble in the cylinder, allowing higher tumble-swirl conversion efficiency.

  • PDF

Characteristics of Unsteady Flows in a Semi-Induction System by a Variable Volume Helmholtz Resonator (가변 체적 헬름홀츠 공진기에 의한 유사 흡기 시스템의 비정상 유동특성)

  • Kang, K.E.;Kim, K.H.;Kang, H.Y.;Koh, D.K.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.57-62
    • /
    • 2009
  • Unsteady flows in a semi-induction system was investigated to verify their characteristics. A semi-induction system was designed and made to verify the Sow characteristics in an intake system. To attain an intact wave of an intake pulse, a single semi-intake system was adopted as a test rig. The system consists of an intake pipe and a rotary valve as a pulse generator, and a variable volume Helmholtz resonator. The variable volume Helmholtz resonator was mounted in the intake pipe to enhance a breathing capacity and engine performance. The phase and amplitude of the pulsating flow in an unsteady flow system were found to affect the charging capacity significantly. The behavior of pressure wave, their phase and amplitude were investigated in various regions. Some of the results obtained from experiments were described.

  • PDF

Efficiency Analysis for Water Turbine Generator of Agricultural Reservoir (농업용 보의 수차 발전기 효율 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1223-1227
    • /
    • 2013
  • If the factory test efficiency and field operation efficiency of water turbine are different from each other, issues for efficiency warranty can be raised. So, This paper shows the result for comparative analysis of field operating efficiency vs plant testing efficiency of the water turbine generator installed in agricultural reservoir. The efficiency of the induction generator is analyzed by the change of rotational speed with the parameter obtained by test, the efficiency of water turbine is calculated by the change of head with the design flow. Efficiency deviation of induction generator is lower but the variation of developed power is pretty high near the rated speed and the efficiency variation of water turbine is high by the fluctuation of head for constant flow. It was found that factory test efficiency and total efficiency of water turbine generator calculated according to the rotational speed are very close.

Effect of Mold Temperature on Injection Molding of Micro-Features with High Aspect Ratio (고세장비 미세형상 사출성형시 금형온도의 영향 고찰)

  • Park, Jung-Min;Do, Bum-Suk;Eom, Hye-Ju;Park, Keun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1124-1128
    • /
    • 2008
  • Thin-wall injection molding is associated with many advantages, including increased portability, the conserving of materials, and the reduction of the molding cycle times. In the application of the thin-wall molding, a considerable reduction of the effective flow thickness results in filling difficulty. High-frequency induction is an efficient way to overcome this filling difficulty by means of heating the mold surface by electromagnetic induction. The present study applies the induction heating to the injection molding of thinwalled micro structures with high aspect ratio. The feasibility of the proposed heating method is investigated through a numerical analysis. The estimated filling characteristics of the micro-features are investigated with variations of mold temperature and part thickness, of which results are also compared with experimental measurements.

  • PDF

Numerical Study on the Cooling of Induction Motor In a Washing Machine (세탁기용 유도모터의 냉각에 관한 수치적 연구)

  • Hong, Sang-Wook;Jeon, Si-Moon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.266-271
    • /
    • 2003
  • The numerical study was carried out to effectively cool Induction motor applied to a washing machine. The outer rotor made of steel periodically spins up and down. The stator consists of the thin layered iron plates and copper coil. The effective cooling system is necessary to solve the reliability problem caused by the electric losses at the coil and the iron plate. Because the heat transfer rate of the natural convection in partially open space is generally low, thus it is necessary to enhance the heat transfer using rotating perforated plate. The flow phenomena around the motor are very complex due to the motor geometry and the outer rotor motion. The mixed convection takes place due to the slow rotation speed. The three dimensional flow simulation was performed using rotating reference frame technique and Boussinesq approximation but the radiation effect was neglected. It was found that the angle and direction of the cooling blades play an important role in the stator temperature.

  • PDF

A Study on the Induction Heating Analysis of Round bar for TR forging (TR단조를 위한 환봉의 유도가열 해석에 관한 연구)

  • Song, M.C.;Park, D.S.;Lee, M.G.;Lee, K.B.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.194-197
    • /
    • 2009
  • The TR forging is a kind of continuous grain flow forging. The preform of crank shaft for TR forging process was a round bar with a ring groove. In the first stage, the preform was partly heated by induction heating and then forged by vertical and horizontal force in sequence. In this study, the simulation process of induction heating was proposed to evaluate the temperature distribution of preform for TR forging. The equivalent circuit method was adopted to find coil current of the preform with a various dimensions and power levels. With these results, the coupled electromagnetic and transient thermal analysis for induction heating was performed to evaluate the temperature distribution at the preform of crank shaft during induction heating process. This FE analysis technique with equivalent circuit method was verified by comparing the analysis results with the experimental results.

  • PDF

Finite Element Analysis of Induction Heating Process for Development of Rapid Mold Heating System (급속 금형가열 시스템 개발을 위한 고주파 유도가열 과정의 유한요소해석)

  • Hwang, J.J.;Kwon, O.K.;Yun, J.H.;Park, K.
    • Transactions of Materials Processing
    • /
    • v.16 no.2 s.92
    • /
    • pp.113-119
    • /
    • 2007
  • Rapid mold heating has been recent issue to enable the injection molding of thin-walled parts or micro/nano structures. Induction heating is an efficient way to heat material by means of an electric current that is caused to flow through the material or its container by electromagnetic induction. It has various applications such as heat treatment, brazing, welding, melting, and mold heating. The present study covers a finite element analysis of the induction heating process which can rapidly raise mold temperature. To simulate the induction heating process, the electromagnetic field analysis and transient heat transfer analysis are required collectively. In this study, a coupled analysis connecting electromagnetic analysis with heat transfer simulation is carried out. The estimated temperature changes are compared with experimental measurements for various heating conditions.

Effects of alfaxalone on echocardiographic examination in healthy dogs

  • Kim, Ye-Won;Kim, Tae-Jun;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.4
    • /
    • pp.221-225
    • /
    • 2015
  • This study evaluated the effects of alfaxalone (3 mg/kg, intravenously) on echocardiographic examination in healthy dogs using echocardiography. Six adult Beagle dogs were used for this study. Left ventricular dimensions with systolic indexes, trans-blood flow at all cardiac valvular annulus and trans-mitral tissue Doppler values were measured from routine transthoracic echocardiography. Although the changes were not statistically significant, heart rate, left ventricular end-systolic diameter, left ventricular end-diastolic diameter, peak velocities of tricuspid A-wave and transpulmonic flow were increased after alfaxalone induction, while systolic blood pressure, fractional shortening, left ventricular ejection fraction, peak velocities of mitral E-wave, mitral A wave, tricuspid E-wave, transaortic flow and medial e'-, a'- and s'-peaks decreased after alfaxalone induction. No dogs showed hypoxemia during sedation, regardless of intubation and oxygen supply. Although alfaxalone showed mild cardiovascular depression, this protocol could be a good alternative sedative protocol for echocardiographic examination in healthy dogs because the cardiovascular depression was statistically and clinically insignificant. However, further studies in dogs with heart diseases should be conducted to confirm these findings after alfaxalone induction.

Flow Control Inside a Molten Zn Pot for Improving Surface Quality of Zinc Plated Strips (아연도금강판의 품질향상을 위한 도금욕 내부 유동제어 연구)

  • Choi, Jae-Ho;Koh, Min-Seok;Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1392-1399
    • /
    • 2001
  • The flow fields inside a molten Zn pot of continuous hot-chip galvanizing process were investigated experimentally. With varying several parameters including the strip speed Vs, flow rate Q of induction heater. scrapper location and baffle configuration, instantaneous velocity fields were measured using a PIV velocity field measurement technique. Inside the strip region, counter-clockwise rotating flow is dominant. The general flow pattern inside the strip region is nearly not influenced by the strip speed Vs, flow rate Q and the scrapper location. In the exit region, the flow separated from the moving strip due to the existence of a stabilizing roll ascends to the free surface, for the cases of no scrapper and scrapper detached form the roll. On the other hand, the ascending flow to the free surface is decreased, as the flow rate Q of induction heater increases. By installing a baffle around the uprising strip, the flow moving up to the stabilizing roll decreases. In addition, B-type baffle is better than A-type baffle in reducing speed of flow around the stabilizing rolls. However, the flow ascended to the free surface is largely influenced by changing the flow rate Q, and the scrapper location, irrespective of the baffle type.