• 제목/요약/키워드: flow field design

검색결과 945건 처리시간 0.026초

FDM을 이용한 층유유동장내에서 오염물질확산에 관한 연구 (Numerical Prediction of Contaminant Dispersion within the Laminar Flow Field using FDM)

  • 김양술
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.56-63
    • /
    • 1995
  • A simulation of contaminant dispersion in a water reservoir has been done using 2-D finite difference method(FDM). The steady state velocity field of the reservoir was computed using stream function-vorticity formulation of Wavier-Stokes equation and continuity equation. Based on the computed steady state velocity field, the transient convective diffusion equation of the contaminant dispersion was computed. For the 1m$\times$1m reservoir model with inlet and outlet attached, it was shown that the center of circulation located toward right. For the numerical values of v =0.01($\textrm{cm}^2$/s) and D=0.6($\textrm{cm}^2$/s) and the flow of 50($\textrm{cm}^3$/s ), it was determined that the outflow had to be shut down in 18 seconds to prevent from severe pollution. Also the required time was computed to be 6 seconds for the inflow of 100 ($\textrm{cm}^3$/s). The result of this study is considered, hopefully, to be useful for the design of the water reservoir systems that are the subjects to various contamination.

  • PDF

물수지분석 기법에 의한 양수장 몽리구역내 농업용수 회귀율 연구 (A Study on Return Flow Ratio of Irrigation for a Paddy Field in Pumping Station by Water Balance Method)

  • 추태호
    • 한국수자원학회논문집
    • /
    • 제37권3호
    • /
    • pp.249-255
    • /
    • 2004
  • 농업용수 회귀율을 조사하기 위하여 2003년 관개기 동안 많은 실측을 수행하였다. 본 연구지역은 경상남도 창녕군에 위치한 대암양수장 유역일원이다. 관개용수를 공급하기위하여 건설된 대암 양수장 유역 내 논에 대하여 물수지분석을 실시하였다. 본 연구지역에서의 일 강우량 자료를 수집하였으며, 또한 관개율, 배수율, 침투 및 증발산을 실측하였다. 관개량과 배수량은 기록형수위계(GTDL-L10)를 설치하여 관계기 동안 지속적으로 관측하였다 침투 및 증발산은 직경 3mm PVC 감수심계 및 직경 200mm PVC 침투계를 이용하여 측정하였다. 총관개량 및 총 지표배수량은 654.7mm와281.2mm로 나타났으며, 총 침투량과 총증발산량은 각각 36.0mm 및 160.0mm였고, 일평균 증발산량은 4.3mm/d 였다. 신속회귀율과 지연회귀율은 각각 43.0% 및 5.5%로 전체회귀율은 48.5 %로 나타났다. 따라서, 본 시험지구에서 공급된 관개용수량이 설계기준보다 훨씬 많은 양의 관개용수를 공급하고 있음을 알 수 있었다. 이는 적정한 용수관리원칙 보다는 지역주민들의 요구에 의한 과다공급으로 인한 부적적한 용수관리에 기인하는 것으로, 추후에 농업용수설계기준을 현실에 맞게 변경해야함을 의미한다.

금속분말 사출성형 제품의 공정능력분석에 관한 연구 (A Study on the Process Capability Analysis of MIM Product)

  • 최병기;이동길;최병희
    • 한국생산제조학회지
    • /
    • 제19권1호
    • /
    • pp.57-64
    • /
    • 2010
  • Metal Injection Molding (MIM) is attractive because it produces consistent, complex-geometry components for high-volume, high-strength, and high-performance applications. Also MIM using in optical communication field, display field, and semi-conductor field is a cost-effective alternative to metal machining or investment casting parts. It offers tremendous single-step parts consolidation potential and design flexibility. The objective of this paper is to study the suitability of design, flow analysis, debinding and sinterin processes, and capability analysis. The suitable injection conditions were 0.5~1.5 second filling time, 11.0~12.5 MPa injection pressure derived from flow analysis. The gravity of the product is measured after debinding an sintering. The maximum and minimum gravity levels are 7.5939 and 7.5097. the average and standard deviation are 7.5579 and 0.0122; when converted into density, the figure stands at 98.154%. According to an analysis of overall capacity, PPM total, which refers to defect per million opportunities(DPMO), stands at 166,066.3 Z.Bench-the sum of defect rates exceeding the actual lowest and highest limits-is 0.97, which translates into the good quality rate of around 88.4% and the sigma level of 2.47.

평판에 충돌하는 초음속 이중 동축제트에 관한 실험적 연구 (An Experimental Study of the Supersonic, Dual, Coaxial Jets Impinging on a Flat Plate)

  • 김중배;이준희;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.739-742
    • /
    • 2002
  • The supersonic, dual, coaxial jet impinging upon a vertical flat plate has recently been applied to a variety of industrial manufacturing processes, since it has several advantages over a conventional supersonic impinging jet. In the present study, experimentation is carried out to investigate the effects of the impinging angle of the annular flow and the design Mach number on the flow field formed over the vertical flat plate. A convergent-divergent nozzle is used to obtain the inner jet flow, its design Mach number being changed between $1.0\;and\;2.0$. The outer annular nozzle has a constant area of the Mach number of 1.0, and its impinging angle of $0^{\circ}\;and\;20^{\circ}$. The primary jet pressure ratio is changed in the range from 6.0 to 10.0 and for the annular flow, the assistant jet pressure ratio is changed from 1.0 to 4.0. The distance between the dual, coaxial nozzle and flat plate is also changed. Detailed pressure measurements are conducted along the axis of the jet and on the flat plate as well. The impinging coaxial Jet flows are visualized using the Schlieren and Shadow optical methods. The results show that the flow field on the plate is not strongly dependent only on the primary and assistant pressure ratios but also the impinging angle of the annular nozzle.

  • PDF

종자계형 진공 인터럽터에서 접점전극 슬릿의 영향에 관한 연구 (A Study on the Effect of the Contact Electrode Slits in the Vacuum Interrupter with Axial Magnetic Field Type)

  • 하덕용;강형부;최승길;최경호
    • 한국전기전자재료학회논문지
    • /
    • 제15권9호
    • /
    • pp.822-829
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density for each slits made on the contact electrode in the vacuum interrupter with axial magnetic field type using 3-dimension finite element analysis. It has been known that the presence of an axial magnetic field parallel to the current flow in the arc plasma can increase the high current breaking capacity of vacuum interrupter by carrying out the arc plasma from constricted mode to diffusion mode. The axial magnetic field is created of itself by current flow in the segments of coil electrode behind the contact electrode. The analyzed results show that if the slits are made in the contact electrode, they can increase the current density and axial magnetic flux density in the contact electrode surface and at the gap distance, which is due to decrease the effect of eddy currents flowing in the contact electrode. The phase shift due to eddy currents, defined 3s time difference between the maximum value of current and axial magnetic field, is decreased still more by increasing the number of slits made in the contact electrode at the center point of gap distance. These results demonstrate that 3-dimension finite element analysis has a great deal of merits in the development and evaluation of new electrode at the design of vacuum interrupter.

분류층 석탄 가스화기 반응 유동장 변수 전산해석 연구 (PARAMETRIC NUMERICAL STUDY OF THE REACTING FLOW FIELD OF A COAL SLURRY ENTRAINED GASIFIER)

  • 송우영;김혜숙;신미수;장동순;이재구
    • 한국전산유체공학회지
    • /
    • 제19권3호
    • /
    • pp.44-51
    • /
    • 2014
  • Considering the importance of the detailed resolution of the reacting flow field inside a gasifier, the objective of this study lies on to investigate the effect of important variables to influence on the reacting flow and thereby to clarify the physical feature occurring inside the gasifier using a comprehensive gasifier computer program. Thus, in this study the gasification process of a 1.0 ton/day gasifier are numerically modeled using the Fluent code. And parametric investigation has been made in terms of swirl intensity and aspect ratio of the gasifier. Doing this, special attention is given on the detailed change of the reacting flow field inside a gasifier especially with the change of this kind of design and operation parameters. Based on this study, a number of useful conclusions can be drawn in the view of flow pattern inside gasifier together with the consequence of the gasification process caused by the change of the flow pattern. Especially, swirl effect gives rise to a feature of a central delayed recirculation zone, which is different from the typical strong central recirculation appeared near the inlet nozzle. The delayed feature of central recirculation appearance could be explained by the increased axial momentum due to the substantial amount of the presence of the coal slurry occupying over the entire gasifier in gasification process. Further, the changes of flow pattern are explained in detail with the gasifier aspect ratio. In general, the results obtained are physically acceptable in parametric study.

Preliminary numerical study of single bubble dynamics in swirl flow using volume of fluid method

  • Li, Zhongchun;Qiu, Zhifang;Du, Sijia;Ding, Shuhua;Bao, Hui;Song, Xiaoming;Deng, Jian
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1119-1126
    • /
    • 2021
  • Spacer grid with mixing vane had been widely used in nuclear reactor core. One of the main feather of spacer grid with mixing vane was that strong swirl flow was formed after the spacer grid. The swirl flow not only changed the bubble generation in the near wall field, but also affected the bubble behaviors in the center region of the subchannel. The interaction between bubble and the swirl flow was one of the basic phenomena for the two phase flow modeling in fuel assembly. To obatin better understanding on the bubble behaviors in swirl flow, full three dimension numerical simulations were conducted in the present paper. The swirl flow was assumed in the cylindral calculation domain. The bubble interface was captured by Volume Of Fluid (VOF) method. The properties of saturated water and steam at different pressure were applied in the simulation. The bubble trajectory, motion, shape and force were obtained based on the bubble parameters captured by VOF. The simulation cases in the present study included single bubble with different size, at different angular velocity conditions and at different pressure conditions. The results indicated that bubble migrated to the center in swirl flow with spiral motion type. The lateral migration was mainly related to shear stress magnitude and bubble size. The bubble moved toward the center with high velocity when the swirl magnitude was high. The largest bubble had the highest lateral migration velocity in the present study range. The effect of pressure was small when bubble size was the same. The prelimenery simulation result would be beneficial for better understanding complex two phase flow phenomena in fuel assembly with spacer grid.

중형 차량 엔진룸에서의 유동해석에 관한 연구 (Study of Flow Analysis of a Mid-size Vehicle in an Engine Room)

  • 이동렬
    • 한국전산유체공학회지
    • /
    • 제9권4호
    • /
    • pp.13-19
    • /
    • 2004
  • Flow distribution of a mid-size vehicle in engine room was investigated numerically to analyze the flow performance of given design cases in a front body of the mid-size vehicle. The data analyzed are the mass flow rate at the upper and lower openings, in the radiator, and the degree of non-uniformity of the velocity field at the inlet of the radiator. It is presented that the shape of the front end and the presence of the undercover greatly affect the flow fields, therefore, the flow performance.

Flow Behavior in a Rectangular Tunnel Opened and Closed at Both Sides Using CFD

  • Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권3호
    • /
    • pp.368-377
    • /
    • 2012
  • Most tunnel simulations have been focused on the thermal field and the critical velocity for suppression of hot back-layering flow in case of fire and on the characteristics of a tunnel fire in terms of the flame propagation and the toxic gas generation. In this paper, a comparative study of the flow characteristics of polluted air with no heat source in a tunnel model opened and closed at both end sides is implemented into a recognized CFD simulation code. The model is used to investigate the flow characteristics depending on the three different Reynolds numbers of 640, 1270 and 2120, which have been chosen by the flow velocities of 0.3, 0.6 and 1.0 m/s through the inlet. The results of this study have shown that the CFD predictive and experimental approaches are available in qualitatively studying the correlation of flow behaviors for a better tunnel design.

압전체로 구동되는 질량흐름 제어기에서 레이놀즈 방정식을 이용한 유량 특성 연구 (A Study of Flow Characteristics using Reynold's Equation on Mass Flow Controller Actuated by Piezoelectric Material)

  • 이상경;김영수
    • 동력기계공학회지
    • /
    • 제7권3호
    • /
    • pp.69-73
    • /
    • 2003
  • In this paper, the relation between displacement of piezoelectric disk and electric field was proposed. From Navier-Stokes equation and Reynold's equation, the relation between flow and gap of plate was determined. This models were further verified by experiments. Based on theoretical study and experimental verification, the proposed model between flow rate and voltage can be used in the design of mass flow controller in gas supplying system.

  • PDF