• Title/Summary/Keyword: flow effect

Search Result 10,898, Processing Time 0.043 seconds

Experimental Analysis of ER Effects about Flow-Mode (Flow Mode 유동에 대한 ER효과의 실험적 해석)

  • 임춘성;이은준;주동우;박명관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1135-1138
    • /
    • 2003
  • ERFs(Electrorheological Fluids) arc a complex system consisting of polarizable particles and insulation liquid. When an external electric field is applied to ERFs, its apparent viscosity increases dramatically. This phenomenon is called the ER effect. Generally, the behavior of ERFs has been modeled on those of Bingham fluids. But the behavior of ERFs differs from those of Bingham fluids in many respects. In the paper, ER effect concerning flow mode of ERFs is analyzed experimentally. According to several flow conditions, the change of ER effect is presented and visualized. A new modeling methodology of ER effect to reduce the modeling error is presented.

  • PDF

Effect of Flow on Purchase Intension (플로우(Flow) 경험이 구매의도에 미치는 영향)

  • Kim, Byung-Cheol;Choi, Soo-Ho
    • Survey Research
    • /
    • v.3 no.2
    • /
    • pp.17-45
    • /
    • 2002
  • The purpose of this study is to examine the effect of the Flow experience on purchase intention. The results of this study show that (1) the purchase intention through internet is increased in proportion to the degree of cognition of users' experience. (2) The "Flow" experiences during the time of navigating internet shopping-mall sites lead to different results due to the separate motive of searching internet shopping-mall sites. (3) It should analyze the market segmentation of internet users, using Flow experience in the future based on the relationship between Flow and on-line and off-line purchase intention. (4) Finally, it should study more profoundly on "experiential" Flow and "goal-directed Flow that it has to analyze the difference in Flow experiences between separate purposes of searching internet shopping-mall sites.

  • PDF

Issues Related to the Modeling of Solid Oxide Fuel Cell Stacks

  • Yang Shi;Ramakrishna P.A.;Sohn Chang-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.391-398
    • /
    • 2006
  • This work involves a method for modeling the flow distribution in the stack of a solid oxide fuel cell. Towards this end, a three dimensional modeling of the flow through a Solid Oxide Fuel Cell (SOFC) stack was carried out using the CFD analysis. This paper examines the efficacy of using cold flow analysis to describe the flow through a SOFC stack. It brings out the relative importance of temperature effect and the mass transfer effect on the SOFC manifold design. Another feature of this study is to utilize statistical tools to ascertain the extent of uniform flow through a stack. The results showed that the cold flow analysis of flow through SOFC might not lead to correct manifold designs. The results of the numerical calculations also indicated that the mass transfer across membrane was essential to correctly describe the cathode flow, while only temperature effects were sufficient to describe the anode flow in a SOFC.

The effect of the flow on the absorption performance of a perforated plate system (다공판 시스템의 흡음성능에 유동이 미치는 영향)

  • 허성욱;제현수;양수영;이동훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.879-884
    • /
    • 2003
  • This paper is to experimentally investigate the effect of the through-flow and grazing-flow on the absorption performance of a perforated plate system. The experiment is performed through the systematic change of the through-flow velocity, grazing-flow velocity, incident sound pressure level, and the geometrical parameters such as the porosity and hole diameter. From the experimental results, it is found that for the nonlinear relationship between the acoustic resistance and incident sound pressure level there is no influence of the through-flow on the absorption performance, but fur the linear relationship between them there is a strong dependence of the absorption performance on the through-flow velocity. It is also shown that the absorption performance is controllable by changing the porosity and hole-diameter in size.

  • PDF

Flow force compensation by stepped spool (계단형상에 의한 스풀밸브의 유동력 보상)

  • 신원규;최현영;신효필;문의준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.745-749
    • /
    • 2002
  • This paper is on the study of flow force compensating method of spool type valve. A simple flow force compensating method using stepped spool is presented in this paper. It is easy to manufacture stepped spool in the presented method because the shape of it is simple. The method has the merit that the size of valve need not be increased. Actuating force required for driving means of spool can be decreased by the compensation of flow force. The effect of presented method is predicted through CFD analysis. The prototypes of flow force compensating Direct Drive Servo-Valve where the result of CFD analysis is reflected are manufactured, and the measurement of flow force is carried out. It is known from the measurement that the effect of flow force compensation is very similar to from CFD analysis.

  • PDF

Flow Force Compensation by Stepped Spool Valve (계단형상에 의한 스풀밸브의 유동력 보상)

  • 신원규;최현영;신효필;문의준
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.145-150
    • /
    • 2003
  • This paper is on the study of flow force compensation for spool type valves. A simple method for flow force compensation using a stepped spool is presented in this paper. It is easy to manufacture the stepped spool of the presented method because the shape of it is simple. The method has another merit that the size of valve need not be increased. Actuating force required for driving the spool can be decreased through the compensation of flow force. The effect of presented method is predicted through CFD analysis. The results of the CFD analysis are also utilized for the optimization of step shape. The prototypes of flow force compensated Direct Drive Servo-Valve are manufactured, and the measurements of flow force are carried out. The measured effect of flow force compensation is very similar to that from the CFD analysis.

Effect of Land Slope on Propagation due to Debris Flow Behavior (전파면의 경사에 따른 토석류 흐름양상에 대한 연구)

  • Lee, Jun Seon;Song, Chang Geun;Kim, Hong Teak;Lee, Seung Oh
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.52-58
    • /
    • 2015
  • As sudden rainfall has happened, the debris flow has occurred in the mountain area. Recently sudden rainfall occurred so frequently caused by abnormal climate. Thus debris flow hazard had consecutively increased damage because of debris flow. Recently, Enormous damage due to debris flow have occurred in Korea. Various studies have been conducted to prevent search debris flow hazard. This study was carried out for debris flow behavior according to the land slope on propagation. It is the important one among factors that are related to the propagation over the city with respect to debris flow discharge and depth. For the numerical simulations in this study, the land slope was varied of 5, 0, $-5^{\circ}$ to investigate the debris flow behavior with the FLO-2D, often recommended by FEMA to simulate debris flow. To verify the performance of FLO-2D, comparison with the USGS experiments (Iverson et al, 2010) was conducted. From numerical results the propagation length of the debris flow was found the most sensitive one. Maximum of debris flow thickness and velocity and structural vulnerabilities were investigated to the effect of land slope. They was became smaller according to land slope of 5, -5, $0^{\circ}$ in the order. As a result, debris flow behavior analysis about the effect of the land slope could contribute to understand the vulnerability of city for debris flow hazards.

Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger (알루미늄 다채널 평판관 증발기 내 냉매분배)

  • Kim Nae-Hyun;Park Tae-Gyun;Han Sung-Pil;Lee Eung-Ryul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.800-810
    • /
    • 2006
  • The R-134a flow distribution is experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous air-water results. The flow at the header inlet is stratified. For the downward flow configuration, the liquid distribution improves as the protrusion depth or the mass flux increases, or the quality decreases. For the upward configuration, the liquid distribution improves as the mass flux or quality decreases. The protrusion depth has minimal effect. For the downward configuration. the effect of quality on liquid distribution is significantly affected by the flow regime at the header inlet. For the stratified inlet flow, the liquid is forced to rear part of the header as the quality decreases. However, for the annular inlet flow, the liquid was forced to the frontal part of the header as the quality decreased. For the upward flow, the effect of the mass flux or quality on liquid distribution of the stratified inlet flow is opposite to that of the annular inlet flow. The high gas velocity of the annular flow may be responsible for the trend. Generally, the liquid distribution of the stratified inlet flow is better than that of the annular inlet flow. Possible explanation is provided from the flow visualization results.

The Role of Internet Self-efficacy in Internet Shopping (인터넷 쇼핑에서 인터넷 자기효능감의 역할)

  • Lee, Hobae;Kwon, Nam Kyeong
    • Asia Marketing Journal
    • /
    • v.8 no.2
    • /
    • pp.27-62
    • /
    • 2006
  • This study suggested the internet self-efficacy construct for explaining consumer's searching information capability. It proposed that consumers who have a high internet self-efficacy feel confident they can search much information which they want to find. And it suggested if consumers have a high internet self-efficacy, they will perceive risk less and will experience flow when they use internet shopping mall also. To examine that effect of internet self-efficacy on flow, perceived risk, attitude, and purchase intention, It suggested hypotheses from the basis of prior studies. All of hypotheses were supported and the findings can be summarized as follows. First, internet self-efficacy had a positive effect on flow and a negative effect on perceived risk. Second, flow had a positive effect on attitude and perceived risk had a negative effect on attitude. Attitude had a positive effect on purchase intention also. In view of the result of analysis, between flow and purchase intention are mediated by and between perceived risk and purchase intention are mediated by attitude also. Finally, perceived risk didn't have an effect on flow.

  • PDF

The effect of position of propeller fan relative to duct inlet on flow characteristics (프로펠러 팬과 덕트와의 상대위치가 유동특성에 미치는 영향)

  • Sim, W.C.;Cho, K.R.;Joo, W.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.14-22
    • /
    • 1997
  • The position of propeller fan from duct inlet is one of basic parameters for the design of propeller fan. To investigate the effect of its position on fan characteristics, the inlet flow fields and relative flow angles were measured by a 5-hole pitot tube. The experimental results indicate that the ratio of radial flow introduced from propeller circumference to total inlet flow increases with the increase of propeller distance from duct inlet. When fan operates without duct, the total flow rate and the radial flow ratio are higher than those of any other positions of propeller relative to duct inlet. The radial flow ratio decreases as a flow coefficient and the propeller distance decrease. Therefore the front flow fields can be adjusted in some extent by varying the propeller distance according to a fan loading. The inlet flow angles are decreasing a little as a rotational speed and the propeller distance decrease. In the present case it was judged that the deviation angle of outlet flow became negative owing to a flow separation near a trailing edge.

  • PDF