• Title/Summary/Keyword: flow control function

Search Result 612, Processing Time 0.028 seconds

A New Joint Packet Scheduling/Admission Control Framework for Multi-Service Wireless Networks

  • Long Fei;Feng Gang;Tang Junhua
    • Journal of Communications and Networks
    • /
    • v.7 no.4
    • /
    • pp.408-416
    • /
    • 2005
  • Quality of service (QoS) provision is an important and indispensable function for multi-service wireless networks. In this paper, we present a new scheduling/admission control frame­work, including an efficient rate-guaranteed opportunistic scheduling (ROS) scheme and a coordinated admission control (ROS­CAC) policy to support statistic QoS guarantee in multi-service wireless networks. Based on our proposed mathematical model, we derive the probability distribution function (PDF) of queue length under ROS and deduce the packet loss rate (PLR) for individual flows. The new admission control policy makes admission decision for a new incoming flow to ensure that the PLR requirements of all flows (including the new flow) are satisfied. The numerical results based on ns-2 simulations demonstrate the effectiveness of the new joint packet scheduling/admission control framework.

Development of Three Phase Optimal Power Flow for Distributed Generation Systems (분산전원계통을 위한 3상 최적조류계산 프로그램 개발)

  • Song, Hwa-Chang;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.882-889
    • /
    • 2010
  • This paper presents a method of finding the optimal operating point minimizing a given objective function with 3 phase power flow equations and operational constraints, called 3 phase optimal power flow (3POPF). 3 phase optimal power flow can provide operation and control strategies for the distribution systems with distributed generation assets, which might be frequently in unbalanced conditions assuming that high penetration rate of renewable energy sources in the systems. As the solution technique for 3POPF, this paper adopts a simulation-based method of particle swarm optimization (PSO). In the PSO based 3POPF, a utility function needs to be defined for evaluation of the degree in operational improvement of each particle's current position. To evaluate the utility function, in this paper, NR-based 3 phase power flow algorithm was developed which can deal with looped distributed generation systems. In this paper, illustrative examples with a 5-bus and a modified IEEE 37-bus test systems are given.

Relationship Between Trunk Control and Respiratory Function in Stroke Patients (뇌졸중 환자의 체간조절과 호흡기능의 관계)

  • Lee, Kyeong-Jin;Kim, Nan-Soo
    • Archives of Orthopedic and Sports Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.25-32
    • /
    • 2018
  • Purpose: This study aimed to investigate the relationship between trunk control and pulmonary function and respiratory muscle strength in stroke patients. Methods: This study included 30 patients who had been clinically diagnosed with strokes, and trunk control abilities were measured using the trunk impairment scale (TIS). The subjects were classified into a group with high trunk control ability (TIS score ${\geq}20$) and a group with low trunk control ability (TIS score < 20). The patients' forced vital capacity (FVC), forced expiratory volume in one second (FEV1), peak expiratory flow (PEF), maximal inspiratory pressure (MIP), and maximal expiratory pressure (MEP) were measured. To compare the pulmonary function and respiratory muscle strength between the two groups, the measurement data were analyzed using an independent T-test, and the relationship between TIS and respiratory function was analyzed using a Pearson correlation. Results: The high trunk control ability group had significantly higher pulmonary function and respiratory muscle strength than the low trunk control ability group. Significant positive correlations were found between trunk control and FVC, FEV1, PEF, MIP, and MEP. Conclusions: This study demonstrated that trunk control affects pulmonary function and respiratory muscle strength in stroke patients.

Software Attack Detection Method by Validation of Flow Control Instruction’s Target Address (실행 제어 명령어의 목적 주소 검증을 통한 소프트웨어 공격 탐지 기법)

  • Choi Myeong-Ryeol;Park Sang-Seo;Park Jong-Wook;Lee Kyoon-Ha
    • The KIPS Transactions:PartC
    • /
    • v.13C no.4 s.107
    • /
    • pp.397-404
    • /
    • 2006
  • Successful software attacks require both injecting malicious code into a program's address space and altering the program's flow control to the injected code. Code section can not be changed at program's runtime, so malicious code must be injected into data section. Detoured flow control into data section is a signal of software attack. We propose a new software attack detection method which verify the target address of CALL, JMP, RET instructions, which alter program's flow control, and detect a software attack when the address is not in code section. Proposed method can detect all change of flow control related data, not only program's return address but also function pointer, buffer of longjmp() function and old base pointer, so it can detect the more attacks.

A Numerical Study on the Flow Characteristics of Temperature Control Valve by Pressure Compensation (압력 평형식 온도조절 밸브 내부 유동 특성에 대한 수치적 연구)

  • Hwang, J.H.;Kim, T.A.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.448-453
    • /
    • 2005
  • Temperature Control Valve (TCV) is one of the useful temperature control devices, which is used to control constant temperature of working fluid in power and chemical plants and domestic water supply systems. TCV is composed of body, cylinder and piston, and the body shape has a symmetrical H-type. In general, it has several inlet and outlet holes, and its shape is like as tubular sleeve. The piston has three rings two rings of the end of piston have the function of controlling inlet flow rate with hot and cold working fluids, the center ring has the function of preventing hot and cold water from intermixing. Consequently, the shapes of piston and cylinder are the main design parameters in the performance of TCV. In this study, numerical analyses were carried out with two different piston and cylinder shapes to investigate the functions as a temperature control valve and the flow characteristics according to piston opening grade in TCV. Using a commercial code, FLUENT, velocity and pressure fields in TCV are obtained under steady, standard $k -{\epsilon}$ turbulence model and no-slip condition.

  • PDF

Active Controls of Flow Over a Sphere for Drag Reduction (능동제어를 이용한 구의 저항 감소)

  • Jeon, Seung;Choi, Hae-Cheon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.199-202
    • /
    • 2006
  • The objective of this study is to propose methods of controlling the wake behind a sphere for drag reduction using the suboptimal control theory and surrogate management framework, respectively. The Reynolds numbers considered is 300 at which the base flow is unsteady planar symmetric. Given the cost function defined as the square of the difference between the target pressure (potential-flow pressure) and real flow pressure on the sphere surface, the suboptimal control makes the flow steady axisymmetric and produces drag reduction. Based on the actuation profile from the suboptimal control, the optimal wavy actuation profile is obtained using the surrogate management framework and produces drag reduction.

  • PDF

The Effects on Respiratory Strength Training on Respiratory Function and Trunk Control in Patient with Stroke (호흡 강화 훈련이 뇌졸중 환자의 호흡기능 및 체간조절 능력에 미치는 효과)

  • Kim, Min-Hwan;Lee, Wan-Hee;Yun, Mi-Jung
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.5
    • /
    • pp.340-347
    • /
    • 2012
  • Purpose: This study was conducted in order to investigate the effect on respiratory function, trunk control, and functional activities of daily living (ADL) through respiratory muscle strength training in patients with chronic stroke. Methods: Eighteen subjects who were six months post stroke participated in this study. The subjects were randomly allocated to two groups: experimental (n=10) and control (n=8). Both groups received physical therapy for five sessions, 30 minutes per week, during a period of six weeks. Subjects in the experimental group participated in an additional respiratory muscle strength training program, in which the threshold PEP device was used for 30 minutes per day, three days per week, during a period of six weeks. Results from pretest-posttest control were evaluated by pulmonary function forced vital capacity (FVC), forced expiratory volume at one second (FEV1), FEV1/FVC, peak expiratory flow (PEF), capacity of cough, trunk control, and functional ADL. Results: Significant improvement in the FEV1, PEF of pulmonary function (p<0.05), cough function (p<0.05), and trunk control (p<0.05) was observed among the groups. Conclusion: Respiratory muscle strength training improves pulmonary function, capacity of cough, and trunk control. These results suggest that respiratory muscle strength training is feasible and suitable for individuals with chronic stroke.

The Effects of Respiratory Muscle Training on Respiratory Function, Respiratory Muscle Strength, and Cough Capacity in Stroke Patients (호흡근 강화 훈련이 뇌졸중 환자의 호흡기능, 호흡근력과 기침능력에 미치는 영향)

  • Jo, Myeong-Rae;Kim, Nan-Soo;Jung, Ju-Hyeon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.399-406
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the effects of respiratory muscle training on respiratory function, respiratory muscle strength, and cough capacity in stroke patients. METHODS: This study used a nonequivalent control group pre-post test design. We recruited thirty-four stroke patients(16male, 18female), who were assigned to intervention (n=17), or control (n=17) groups. Both groups participated in a conventional stroke rehabilitation program, with the intervention groups also receiving respiratory muscle training 20 minutes a day, three times a week, for 4 weeks. Respiratory function (forced vital capacity) and respiratory muscle strength (maximal inspiratory pressure, maximal expiratory pressure) were assessed by spirometry. Cough capacity (peak expiratory flow) was assessed using a peak flow meter. The collected data were analyzed by independent and paired t-tests. RESULTS: The intervention group showed a significant increase in the forced vital capacity (FVC), maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP) and peak expiratory flow (PEF) at the end of the program, while the control group showed no significant changes. CONCLUSION: This study showed that respiratory muscle training increased respiratory function, respiratory muscle strength, and cough capacity in stroke patients and prevented a decrease in cough capacity. These findings suggest that respiratory muscle training effect on respiratory function, respiratory muscle strength and cough capacity for rehabilitation in patients with stroke.

A Study on a Novel Flow Control Valve for Wind Power Heat Generation Hydraulic Systems (풍력 열발생 유압 시스템을 위한 새로운 유량제어밸브에 관한 연구)

  • Choi, Sae Ryung;Lee, Ill Yeong;Han, Bong Jun
    • Journal of Drive and Control
    • /
    • v.14 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • A wind power heat generation system that converts wind power directly to heat instead of electric power is considered in this study. The system consists of a wind turbine part and a heat generation part. The heat generation part is materialized by a hydraulic system including a hydraulic pump, a flow control valve, a hydraulic oil tank, etc. The flow control valve primarily converts hydraulic energy generated in the pump to heat energy. It should have a function of overspeed protection under excessive wind speeds. In this study, a novel flow control valve design is proposed for excellent flow control characteristics under excessive pump driving torque (excessive wind speed). The performance of the suggested valve is analyzed using numerical simulation.

Study of Optimal Location and Compensation Rate of Thyristor-Controlled Series Capacitor Considering Multi-objective Function

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jin-Su;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.428-435
    • /
    • 2013
  • Flexible AC Transmission System (FACTS) application study on enhancing the flexibility of AC power system has continued to make progress. A thyristor-controlled series capacitor (TCSC) is a useful FACTS device that can control the power flow by adjusting line impedances and minimize the loss of power flow and voltage drop in a transmission system by adjusting line impedances. Reduced power flow loss leads to increased loadability, low system loss, and improved stability of the power system. This study proposes the optimal location and compensation rate method for TCSCs, by considering both the power system loss and voltage drop of transmission systems. The proposed method applies a multi-objective function consisting of a minimizing function for power flow loss and voltage drop. The effectiveness of the proposed method is demonstrated using IEEE 14- and a 30-bus system.