• 제목/요약/키워드: flow control device

검색결과 408건 처리시간 0.032초

Synthetic Jet을 이용한 유동제어 특성연구 (A STUDY ABOUT FLOW CONTROL CHARACTERISTICS USING A SYNTHETIC JET)

  • 홍우람;김상훈;김우레;김유신;김종암
    • 한국전산유체공학회지
    • /
    • 제12권2호
    • /
    • pp.1-7
    • /
    • 2007
  • To develop an aerodynamic performance, two groups of studies have been achieved widely. One is about the geometric design of vehicles and the other is about aerodynamic devices. Geometric design is a credible and stable method. However, it is not flexible and each part is related interactively. Therefore, if one part of geometry is modified, the other part will be required to redesign. On the other hand, the flow control by aerodynamic devices is flexible and modulized method. Even though it needs some energy, a relatively small amount of input makes more advanced aerodynamic performance. Synthetic jet is one of the method in the second group. The device repeats suctions and blowing motions in constant frequency. According to the performance, the adjacent flow to flight surface are served momentum. This mechanism can reduce the aerodynamic loss of boundary layer and separated flow. A synthetic jet actuator has several parameters, which influences the flow control. This study focuses on the parameter effects of synthetic jet - orifice geometry, frequency, jet speed and etc.

임베디드 웹서버를 이용한 Synthetic Jet Actuator의 풍동실험장치 개발 (A Development of Wind Tunnel Test System for Synthetic Jet Actuator with Embedded Web Server)

  • 정규홍
    • 대한기계학회논문집A
    • /
    • 제29권5호
    • /
    • pp.639-646
    • /
    • 2005
  • As the internet communication is prevalent in recent years, it becomes quite possible to monitor and control some mechanical plants from the remote place through the TCP/IP communication. Such a concept is expected to be applied to many industrial systems fur easy maintenance and trouble shooting as well as various kinds of expensive test equipments fo. sharing. Synthetic jet actuate.(SJA) is a kind of high-lifting device to prevent flow separation at high angle of attack and its use for flow control has received a great amount of attention. In this research, remote control and data monitoring system for SJA wind tunnel test is implemented by TCP/IP communication with DSP as a embedded web server. From the tests performed with embedded server, it showed the possibility of reliable remote control system design utilizing the internet communication.

펠티어 소자를 이용한 사출 금형의 온도제어 (Active Control of Injection Mold Temperature using the Peltier Device)

  • 조창연;신홍규;박동영;홍남표;김병희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.183-186
    • /
    • 2007
  • The injection molding process has high accuracy and good reproducibility that are essential for mass production at low cost. Conventional molding processes typically use the water-based mold heating and air cooling methods. However, in the nano injection molding processes, this semi-active mold temperature control results in the several defects such as air-flow mark, non-fill, sticking and tearing, etc. Therefore, in order to control temperature of the molds actively and improve the quality of the molded products, the novel nano injection molding system, which uses active heating and cooling method, has been introduced. By using the Peltier devices, the temperature of locally adiabatic molds can be controlled dramatically and the quality of the molded patterns can be improved.

  • PDF

Application of Coanda Effects to a Ship Hydrofoil

  • Oh, Jung-Keun;Ahn, Hae-Seong;Kim, Hyo-Chul;Lee, Seung-Hee;Lew, Jae-Moon
    • Journal of Ship and Ocean Technology
    • /
    • 제7권2호
    • /
    • pp.29-39
    • /
    • 2003
  • A Coanda foil is a high-lift generating device exploiting the phenomena that flow separation is delayed if a high-speed jet is applied tangential to the surface as well known to the aerodynamic fields. In the present study, a Coanda foil with a flap is investigated to seek the possibility of marine application. Model experiments are carried out both in a towing tank and cavitation tunnel and surface pressure distributions, forces and moments acting on the foil are measured at the various angle of attacks and flap angles. The results are also compared to the numerical ones to show good agreements. The results of the present study demonstrate the practical applicability of the Coanda foil in the design of ship control surfaces.

Temperature Controllable HPLC Column for Preparative Fractionation of Polymers

  • Im, Kyu-Hyun;Park, Hae-Woong;Kim, Young-Tak;Chang, Tai-Hyun
    • Macromolecular Research
    • /
    • 제16권6호
    • /
    • pp.544-548
    • /
    • 2008
  • An HPLC column with a self-contained temperature control device was constructed for preparative temperature programmed interaction chromatography. Two Peltier plates were attached to a large bore column ($120{\times}22\;mm$ i.d.) and the column temperature was controlled by PID mode feed back control. At a flow rate of 1.5 mL/min, the column temperature could be increased and decreased at a rate as high as $50^{\circ}C/min$ and $10^{\circ}C/min$, respectively, which is much faster than using a column jacket and bath/circulator. The rapid heating and cooling rates allows a high repetition rate of chromatographic fractionation. The performance of the temperature controllable column was demonstrated successfully by the fractionation of homo-polymer precursors from diblock copolymers.

스트레인 게이지 변위 추정기를 사용한 유동공진 가진기 개발 (The Development of Vibration Exciter Using Strain Displacement Estimator for Flow Resonance)

  • 최재혁;남윤수
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.125-132
    • /
    • 2001
  • Heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate air turbulence which has the natural shedding frequency of heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its' validity is verified by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, the vibration exciter using strain displacement estimator is developed. And in the experiment, the feedback control is used. During the experimental verification phase, it turns out the high modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..

유동공진을 위한 가진기 설계 및 평가 (Design and Evaluation of a Vibration Exciter for the Flow Resonance)

  • 남윤수;최재혁
    • 한국정밀공학회지
    • /
    • 제18권6호
    • /
    • pp.141-147
    • /
    • 2001
  • A heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate an air turbulence which has the natural shedding frequency of a heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is verified by the comparison with experimental data. Values of some unko주 system parameters in the analytic model are estimated through the system identification approach. based on this mathematical model, a high bandwidth vibration exciter is designed using feedback control. During the experimental verification phased, it turns out the high frequency modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

가스흐름 제어에 의한 균일한 다결정 3C-SiC 박막 성장 (The uniform polycrystalline 3C-SiC thin film growth by the gas flow control)

  • 윤규형;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.92-92
    • /
    • 2008
  • The surface flatness of heteroepitaxially grown 3C-SiC thin films is a key factor affecting electronic and mechanical device applications. This paper describes the surface flatness of polycrystalline 3C-SiC thin films by the gas flow control according to the location change of geometric structure. The polycrystalline 3C-SiC thin film was deposited by APCVD(Atmospheric pressure chemical vapor deposition) at $1200^{\circ}C$ using HMDS(Hexamethyildisilane : $Si_2(CH_3)_6)$ as single precursor, and 5 slm Ar as the main flow gas. According to the location of geometric structure, surface fringes and flatness changed. It shows the distribution of thickness is formed uniformly in the specific location of the geometric structure.

  • PDF

PoC 부착 싸이클론의 미세분진 유출 제어에 관한 연구 (Emission Control of Fine Dust from Gas-Solid Cyclone)

  • 조영민
    • 한국대기환경학회지
    • /
    • 제15권2호
    • /
    • pp.201-210
    • /
    • 1999
  • Cyclones have been extensively used in the industry for removing fine particles from the gaseous streams, based on simplicity in design and construction in association with low cost and flexibility to operate in extreme and harsh environments. However, industrial cyclones are typically not very efficient for particles smaller than 10μm. In this work, in order to improve the separation efficiency of reverse flow cyclones, a simple device named Post Cyclone(Poc) in installed on the top of an existing cyclone. Thereby the residual swirl present at the outlet (vortex finder) of a conventional cyclone has been used to capture the escaped dust from the cyclone in the PoC. The performance of PoC was closely evaluated by changing configuration of the PoC and operation condition. In addition, the dust behaviour in th PoC was investigated based on the hypothesis of residual vortex.

  • PDF