• 제목/요약/키워드: flow cell

검색결과 3,119건 처리시간 0.027초

NUMERICAL ANALYSIS OF A SAMPLING MODULE FOR A FAST RESPONSE EXHAUST GAS ANALYZER

  • Kim, W.S.;Lee, J.H.;Yoo, J.S.;Rhee, B.O.;Park, J.I.
    • International Journal of Automotive Technology
    • /
    • 제8권2호
    • /
    • pp.149-154
    • /
    • 2007
  • The engine behavior in a transient condition is important to not only emission regulations but also fuel economy. A fast response gas analyzer can be a useful tool to investigate exhaust gas in a transient operation. It should be designed to analyze gas concentration with a short time constant by a fast sampling module and an appropriate measuring method for each emission element. In this study, a new fast sampling module is introduced and flow analysis is performed by numerical simulation. The analysis has shown the proper operating condition and the sensitivity of the module for practical application. Calculated flow to the sampling module has $0.5{\sim}4%$ error, while backflow toward the expansion tube is expected when pressure in CP (Constant Pressure) chamber is over 0.6 bar. For a stable supply of flow to the optical cell, sample gas pressure should be in the range, $0.35{\sim}1.90$ bar, when the pressure in the CP camber and the optical cell are 0.2 bar and 0.158 bar, respectively.

NUMERICAL ANALYSIS OF TRANSPORT PHENOMENA IN POLYMER ELECTROLYTE FUEL CELLS (고체고분자형 연료전지 내의 이동현상에 대한 수치해석)

  • Park, C.G.
    • Journal of computational fluids engineering
    • /
    • 제12권1호
    • /
    • pp.9-15
    • /
    • 2007
  • A three dimensional numerical model to predict the flow and transport of mixtures and also the electrochemical reactions in polymer electrolyte membrane (PEM) fuel cells is developed. The numerical computation is base on vorticity- velocity method. Governing equations for the flow and transport of mixtures are coupled with the equations for electrochemical reactions and are solved simultaneously including production and condensation of vapor. Fuel cell performance predicted by this calculation is compared with the experimental results and resonable agreements are achieved.

Pedagogical Mathematica Platform Visualizing the Coriolis Effects in 3-Cell Atmospheric Circulation Model

  • Kim, Bogyeong;Yun, Hee-Joong
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권1호
    • /
    • pp.91-99
    • /
    • 2014
  • The atmospheric flow in the 3-Cell model of global atmosphere circulation is described by the Lagrange's equation of the non-inertial frame where pressure force, frictional force and fictitious force are mixed in complex form. The Coriolis force is an important factor which requires calculation of fictitious force effects on atmospheric flow viewed from the rotating Earth. We make new Mathematica platform to solve Lagrange's equation by numerical analysis in order to analyze dynamics of atmospheric general circulation in the non-inertial frame. It can simulate atmospheric circulation process anywhere on the earth. It is expected that this pedagogical platform can be utilized to help students studying the atmospheric flow understand the mechanisms of atmospheric global circulation.

Oscillatory Features of Supersonic Impinging Jet Flows; Effects of the Nozzle Pressure Ratio and Nozzle Plate Distance (노즐 압력비와 충돌면까지의 거리 변화에 따른 초음속 충돌 제트 유동의 진동 특성)

  • Kim S. I.;Park S. O.;Lee K. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.154-159
    • /
    • 2004
  • Numerical simulations of supersonic impinging jet flows are carried out using the axisymmetric Navier-Stokes code. This paper focuses on the oscillatory flow features associated with the variation of the nozzle pressure ratio and nozzle-to-plate distance. Frequencies of the surface pressure oscillation from computational results are in accord with the measured impinging tones for various cases of nozzle-to-plate distance. The variation of this frequency with distance show a staging behavior. Computed results for the case of nozzle pressure ratio variation for a fixed nozzle-to-plate distance also demonstrate a staging behavior. These two seemingly different staging behaviors are found to obey the same frequency-distance characteristics when the frequency and the distance are normalized by using the length of the shock cell.

  • PDF

Measurement of red blood cell aggregation by analysis of light transmission in a pressure-driven slit flow system

  • Shin, S.;Park, M.S.;Jang, J.H.;Ky, Y.H.;Suh, J.S.
    • Korea-Australia Rheology Journal
    • /
    • 제16권3호
    • /
    • pp.129-134
    • /
    • 2004
  • The aggregation characteristics of red blood cells (RBCs) were measured using a newly developed light-transmission slit rheometer. Conventional methods of RBC disaggregation such as the rotational Couette system were replaced with a pressure-driven slit flow system with a vibrational mechanism. Using a vibration generator, one can disaggregate the RBC aggregates stored in the slit. While shear stress decreases exponentially, instantaneous pressure and the transmitted light intensity were measured over time. Applying an abrupt shearing flow after disaggregation caused a rapid elongation of the RBCs followed by loss of elongation with the decreasing shear stress. While the shear stress is further decreasing, the RBCs start to re-aggregate and the corresponding transmitted intensity increases with time, from which the aggregation indices can be obtained using a curve-fitting program.

Electrical Performance Characteristics of 200W PEM-Type Fuel Cells with Variations on Mass Flow Rate and Stack Temperature (공급유량 및 스택온도의 변이에 따른 200W급 PEM형 연료전지의 전기적 성능특성)

  • Hong, Kyung-Jin;Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제58권4호
    • /
    • pp.563-567
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEM-type FCs system was integrated by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with variations on mass flow rate and stack temperature. The ranges of the variations are 1~8L/min on $H_2$ volume and $20{\sim}70^{\circ}C$ on stack temperature.

Flow Cytometric Analysis of Apoptosis Inhibition by Silkworm Hemolymph

  • Lee, Won-Jong;Kim, Eun-Jeong;Park, Tae-Hyeon
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.151-154
    • /
    • 2000
  • The effect of silkworm hemolymph on insect cell apoptosis was investigated. The addition of silkworm hemolymph into the culture medium either before or during the baculovirus infection increased the host cell longevity. Silkworm hemolymph also inhibits apoptosis induced by actinomycin D, the RNA synthesis inhibitor. In this study, a flow cytometry was used for the quantitative analysis of apoptosis inhibition by silkworm hemolymph.

  • PDF

Characteristics of Rotating Stall in a Centrifugal Compressor with Vaned Diffuser (원심압축기 베인 디퓨저에서의 선회실속 특성)

  • Lee, Du-Yeol;Kang, Chang-Sik;Shin, You-Hwan;Kim, Kwang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • 제5권1호
    • /
    • pp.42-48
    • /
    • 2002
  • In this study, the instability of a centrifugal compressor with vaned diffuser was investigated. During unstable operation of the test compressor, pressure fluctuations at different diffuser radius ratios were measured by using high frequency pressure transducers. Two different types of stall, mild and deep stalls, were observed alternately and irregularly at some flow rates where the compressor performance was steeply deteriorated. In this transient zone, the size of rotating stall cell was estimated through the wavelet transform analysis. It was about 45 percents of rotor circumferential space at 300 rpm and not dependent on flow rate.

Characteristics of Rotating Stall in a Centrifugal Compressor with Vaned Diffuser (원심압축기 베인 디퓨저에서의 선회실속 특성)

  • Lee, Du-Yeol;Kang, Chang-Sik;Shin, You-Hwan;Kim, Kwang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.99-105
    • /
    • 2001
  • In this study, the instability of a centrifugal compressor with vaned diffuser was investigated. During unstable operation of the test compressor, pressure fluctuations at different diffuser radius ratios were measured by using high frequency pressure transducers. Two different types of stall, mild and deep stall, were observed alternately and irregularly at some flow rate where the compressor performance was steeply deteriorated. In this transient zone, the size of rotating stall cell was estimated through the Wavelet transform analysis. It was about 45 percents of rotor circumferential space at 3000 rpm and not dependent on flow rate.

  • PDF

Visualization of Interacting Parallel Supersonic Free Jets using NO-LIF

  • Niimi Tomohide;Ishida Toshihiko
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.36-43
    • /
    • 2001
  • The flow field structures of two interacting parallel supersonic free jets are studied by flow visualization using planar laser-induced fluorescence of NO seeded in nitrogen gas. The experiments are carried out for several distances between two orifice centers and for various ratios of the pressure in the reservoir to that in the expansion chamber. The flow fields are visualized mainly on the plane including two jet centerlines and its characteristic shock system, especially a cell structure formed secondly by interaction of two jets, are analyzed. The positions of the normal shock depending on the pressure ratios are also compared.

  • PDF