• Title/Summary/Keyword: flow angle

Search Result 2,907, Processing Time 0.023 seconds

In-Cylinder Compression Flow Characteristics of Helical Port Engines with Wide Valve Angle (나선형 포트를 적용한 광각엔진에서 실린더 내 압축 유동 특성)

  • Ohm, In-Yong;Park, Chan-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • This paper is the second of 2 companion papers which investigate in-cylinder swirl generation characteristics in helical port engine with wide valve angle. Two wide valve-angle engines, which are same ones and have slightly different rig swirl number, were used to compare the characteristics of cylinder-flow. One intake port is deactivated to induce swirl flow. A PIV (Particle Image Velocimetry) was applied to measure in-cylinder velocity field during intake stroke. The results show that the intake flow component passing through valve area near the cylinder wall is not negligible in helical port engine with wide valve angle contrary to conventional one. The effect of this velocity component on in-cylinder increases as the swirl ratio rises and compression process progresses. Consequently, this component destroys in-cylinder swirl flow completely during compression resulting in no actual swirl at the end stage of compression.

In-Cylinder Intake Flow Characteristics of Helical Port Engines with Wide Valve Angle (나선형 포트를 적용한 광각엔진에서 실린더 내 흡입 유동 특성)

  • Ohm, In-Yong;Park, Chan-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.10
    • /
    • pp.761-768
    • /
    • 2008
  • This paper is the first of 2 companion papers which investigate in-cylinder swirl generation characteristics in helical port engine with wide valve angle. Two wide valve-angle engines, which are same ones and have slightly different rig swirl number, were used to compare the characteristics of cylinder-flow. One intake port is deactivated to induce swirl flow. A PIV (Particle Image Velocimetry) was applied to measure in-cylinder velocity field during intake stroke. The results show that the intake flow component passing through valve area near the cylinder wall is not negligible in helical port engine with wide valve angle contrary to conventional one. The effect of this velocity component on in-cylinder increases as the swirl ratio rises and intake process progresses. Consequently, this component interferes the formation of in-cylinder swirl flow resulting in lower actual swirl.

Performance of an Axial Turbo Fan by the Revision of Impeller Pitch Angle (피치각 수정에 따른 축류식 터보팬 성능 변화에 관한 연구)

  • Kang Seok-Youn;Lee Tae-Gu;Ryu In-Keun;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.268-276
    • /
    • 2005
  • The aim of this paper is to suggest one efficient method for the various requirements of performance during the process designing and producing an impeller. The study considers that the revisions of a pitch angle of an impeller at an axial turbo fan affect an air flow rates and a static pressure rise. The axial turbo fan specified with the 250 Pa maximum static pressure and 1300 CMH fan air flow rates was tested and analyzed by CFD. The Numerical results show that the air flow rates are calculated to 1,175 CMH, 1,223 CMH, 1,270 CMH, 1,340 CMH and 800 CMH in cases that the pitch angles are $44^{\circ},\;49^{\circ},\;54^{\circ},\;59^{\circ},\;and\;64^{\circ}$ respectively. Also the static pressure rises are shown to 108 Pa, 122Pa, 141 Pa, 188 Pa and 63 Pa at the same cases. The air flow rate is increased linearly according to the changes of the pitch angle from $44^{\circ}\;to\;59^{\circ}$ and the maximum air flow rate passing the impeller is increased to $13\%$ over at the case of $59^{\circ}$ pitch angle compared with the reference case of $54^{\circ}$ pitch angle. The static pressure rise is increased linearly according to the changes of the pitch angle from $44^{\circ}\;to\;54^{\circ}$, too. The static pressure rise at the $59^{\circ}$ pitch angle is increased to $33\%$ over compared with the $54^{\circ}$ pitch angle. The result shows that the revisions of pitch angle make the static pressure rise increase widely. However the air flow rates and the static pressure rise at the $64^{\circ}$ pitch angle are suddenly decreased because of over-changed pitch angle.

Three-Dimensional Flow Characteristics in the Downstream Region of a Butterfly-Type Valve Used in Air-Conditioning Systems (공기조화용 버터플라이 밸브 하류에서의 3차원 유동특성)

  • Park, Sang-Won;Lee, Sang-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.260-269
    • /
    • 2000
  • Oil-film flow visualizations and three-dimensional flow measurements have been conducted in the downstream region of a butterfly-type valve used in air-conditioning systems, with the variation of a disk open angle. The flow visualizations in the flow symmetry plane show that there are a pair of counter-rotating separation/recirculation zones as wall as two jet-like near-wall flows. These flow disturbances are strongly depends on the disk open angle. Based on the flow visualization, a qualitative flow model is suggested in the near-field and downstream region of the valve disk. For a small disk open angle, the mean velocities and turbulent intensities have relatively small values in the near-field of the valve disk, but they do not show uniform distributions even in some downstream region. With an increment of the disk open angle, mean velocity variations and turbulent intensities are greatly increased in the immediate downstream region, but uniform distributions are quickly resumed as departing from the valve disk. The mass flow rate remains nearly constant for the disk open angles less than 30 degrees, meanwhile it strongly depends on the disk open angles between 45 and 75 degrees. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 75 degrees.

TURBULENT FLOW AROUND AN INCLINED SQUARE CYLINDER (기울어진 정방형 실린더를 지나는 난류 유동)

  • Yoon, Dong-Hyeog;Yang, Kyung-Soo
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.52-58
    • /
    • 2009
  • Turbulent flow past an inclined square cylinder immersed in a cross stream is numerically investigated. The angle of incidence of main flow is one of the key factors determining at which edges the flow separates. In the present study, based on comprehensive numerical simulations, effects of inclination angle on the flow characteristics are elucidated and the related physical explanation is presented.

Optimal response of conical tool semi angle in ductile metal sheets indentation and its governing mechanics

  • Nazeer, Malik M.;Khan, M. Afzal;Haq, A-Ul
    • Structural Engineering and Mechanics
    • /
    • v.16 no.1
    • /
    • pp.47-62
    • /
    • 2003
  • The nonlinear dependence aspect of various conical tool indentation parameters leading to an optimum tool semi angle value for easiest perforation is plotted and discussed explicitly in this work with the conclusion that tool angle has an optimum response towards most of the indentation parameters. Around this optimum angle, the aluminium sheets showed minimum fracture toughness as well as minimum work input to overcome the offered resistance. At the end, the mechanism leading to this phenomenon is presented with the conclusion that plastic flow dominates as the dimple semi cone angle reaches 35 and both pre and post plastic flow perforations lead the tool semi cone angle value towards this dimple cone semi angle of plastic flow initiation for its optimum performance. It is also concluded that specimen material failure is solely under tensile hoop stress and hence results into radial cracks initiation and propagation.

A Study on the Fluid Flow According to the Opening Angle of a Butterfly Valve with High Control Performance (고제어 성능을 가진 버터플라이밸브의 개도각에 따른 유체유동에 대한 연구)

  • Yu, Seong-Hun;Park, Sang-Hee;Hwang, Jeong-Gyu;Yang, Hee-Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.617-623
    • /
    • 2021
  • The objective of this study is to simulate valve flow coefficient and flow characteristics such as velocity and pressure distribution for butterfly valve. The size of the valve used in this study is 125A. The range of the valve opening angle was α=15°~70°, and it was changed by 5°. At the range of α=15°~30°, the valve flow coefficient K𝜐 gradually increased, and after α=30°, it increased rapidly. In the range of α=20°~70°, the pressure change in the -2.9cm~+2.9cm region in the pipe greatly depended on the opening angle and the position within the pipe. However, after +2.9cm, the pressure at the rear end of the valve was shown to depend only on the opening angle. At α=20°, Vortex shedding occurred for the first time at time t=0.25sec and continuously occurred in rear end of the valve over time. After α=45°, in the flow pattern at the rear end of the valve, the upward flow at the lower end of the valve and the flow at the upper end met each other to form a mixed flow. This flow phenomenon was shown to form a more intense mixed flow in the rear end region as the opening angle increased. Vortex flow occurred for the first time at α=15°, and the opening angle increased, the occurrence and disappearance of this flow phenomenon occurred periodically according to the certain flow region. The pattern of the pressure distribution in the region at the rear end of the valve showed a tendency to agree well with the results of the vorticity distribution.

Effect of Pitch Angle and Blade Length on an Axial Flow Fan Performance (피치각과 날개 길이에 따른 축류팬의 성능)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • In this study, the performance of an impeller according to blade length and pitch angle was studied experimentally by building a variable pitch impeller while changing blade length to review the effect of blade length and pitch angle on a fan's performance. The pitch angle was changed in six steps from $20^{\circ}{\sim}45^{\circ}$ at intervals of $5^{\circ}$ while the blade lengths were changed to 90 mm, 100 mm, 110 mm and 120 mm with an identical airfoil shape while carrying out the experiment. The results are summarized as follows: The air flow per static pressure of axial fans increased linearly with increase of pitch angle, but the high static pressure showed a decrease at a pitch angle of $35^{\circ}$. The shaft power increased proportionally to the pitch angle at all blade lengths; the larger the pitch angle, the larger the measured increase of shaft power. This is because the drag at the fan's front increases with the pitch angle. In the axial fans considered in this research, the flow and increase of static pressure amount increased up to a pitch angle of $30^{\circ}$ but decreased rapidly above $35^{\circ}$.

Study on the Angle-of-Attack Characteristics of the Rudder in Rotating Propeller Flow (프로펠러 회전류에서 작동하는 방향타의 받음각 특성 연구)

  • Jung, Jae Hwan;Baek, Dong Geun;Yoon, Hyun Sik;Kim, Ki-Sup;Paik, Bu-Geun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.6
    • /
    • pp.421-428
    • /
    • 2013
  • This study aims at numerically investigating the angle of attack characteristics of the rudder behind a rotating propeller. The rotating propeller of 5 blades and the full spade rudder are placed in the numerical water tunnel with a uniform flow condition to consider propeller-rudder interaction. The turbulence closure model is employed to simulate the three-dimensional unsteady incompressible viscous turbulent flow around the propeller and the rudder. The present numerical method are well verified by comparing with the experimental results. In order to identify the dependence of the angle of attack of the rudder on the rudder angle, a wide range of rudder angles is considered. The present study carried out the quantitative and qualitative analysis of the angle of attack in terms of the pressure distribution, streamlines and the evaluation of the flow incidence, resulting in that the angle of attack increases as we move from the root and the tip to the center of the rudder, regardless of the rudder angle. The distribution of the angle-of-attack along the span is strongly affected by rotating propeller flow and rudder angle. Consequently, the distribution of the angle-of-attack of the oncoming flow against the rudder leading edge plays a role in determination of rudder performance.

In-Cylinder Compression Flow Characteristics According to Inlet Valve Angle (흡입 밸브 각도에 따른 압축 행정 중 실린더 내 유동 특성)

  • Ohm, In-Yong;Park, Chan-Jun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.77-83
    • /
    • 2006
  • A PIV(Particle Image Velocimetry) was applied to measure in-cylinder velocity field according to inlet valve angle during compression stroke. Two engines, one is conventional DOHC 4 valve and the other is narrow valve angle, were used to compare real compression flow. The results show that the flow patterns are well arranged compared with intake flow and the basic tumble flow structures are maintained until end compression stage regardless of valve angle. Also the results show that the tumble motion is intensified by momentum conservation during compression in normal engine. In the normal engine, the bulk shape of flow pattern is "Y" type at the top of cylinder and reverse "Y" type at the bottom of cylinder and weak reverse flow exists at the top of cylinder along cylinder center line. Otherwise, the other engine's flow pattern changes from "Y" type to "T" type at the top of cylinder during compression.