• Title/Summary/Keyword: flow analysis

Search Result 17,809, Processing Time 0.045 seconds

Numerical Analysis of the Internal Flow of Small Quick Coupler at 3,000psi (3,000psi급 소형 퀵 커플러 내부유동에 관한 수치해석)

  • Ahn, Hee-Hak;Yi, Chung-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.2
    • /
    • pp.16-21
    • /
    • 2016
  • This study is a numerical analysis of the flow characteristic of a quick coupler. The quick coupler is a popular coupling tool for pipelines in hydraulic and pneumatic systems. In this study, the flow characteristic of a quick coupler outlet is conducted about the flow coefficient. The quick coupler is analyzed for improving flow and confirmed with the study results. The velocities with pressure distribution according to inlet and outlet pressure drop of the coupler are also compared. The flow coefficient is analyzed according to the flow analysis result for each pressure drop. When the pressure drop is 1 psi, the flow coefficient (Cv) matched about 98% of the value provided by the actual product.

Identification of Two-Phase Flow Patterns in a Inclined Duct Based upon a Statistical Analysis of Instantaneous Pressure Drop (순간압력강하치의 통계적 해석을 통한 경사관내 2상유동양식의 판별)

  • Lee, S.C.;Lee, J.P.;Kim, J.Y.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.590-597
    • /
    • 1988
  • Characteristics of flow regime transitions in inclined upwards gas-liquid two-phase flow have been investigated based upon a statistical analysis of instantaneous pressure drop curves through an orifice. The probability density functions of the curves indicate distinct patterns depending upon two-phase flow regime, which are very similar to those of horizontal two-phase. The dimensionless intensity of fluctuations of the pressure drops sharply change as the flow transitions such as plug-slug, pseudo slug-slug and annular-slug take place. The effects of inclination angle on the flow regime transitions have been also investigated. The results show that the method to identify the flow pattern based upon the statistical analysis of instantaneous pressure drops is suitable for inclined flow as well as horizontal flow.

  • PDF

Flow Force Compensation by Stepped Spool Valve (계단형상에 의한 스풀밸브의 유동력 보상)

  • 신원규;최현영;신효필;문의준
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.145-150
    • /
    • 2003
  • This paper is on the study of flow force compensation for spool type valves. A simple method for flow force compensation using a stepped spool is presented in this paper. It is easy to manufacture the stepped spool of the presented method because the shape of it is simple. The method has another merit that the size of valve need not be increased. Actuating force required for driving the spool can be decreased through the compensation of flow force. The effect of presented method is predicted through CFD analysis. The results of the CFD analysis are also utilized for the optimization of step shape. The prototypes of flow force compensated Direct Drive Servo-Valve are manufactured, and the measurements of flow force are carried out. The measured effect of flow force compensation is very similar to that from the CFD analysis.

Flow-based Real-time Traffic Monitoring and Analysis System (Flow 기반 실시간 트래픽 수집 및 분석 시스템)

  • Park, Sang-Hoon;Park, Jin-Wan;Kim, Myung-Sup
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.11a
    • /
    • pp.1061-1064
    • /
    • 2007
  • 네트워크의 효율적인 관리를 위해서는 네트워크의 각 호스트에서 발생하는 트래픽을 실시간으로 모니터링 할 수 있는 시스템이 필요하다. 이러한 모니터링의 효율적인 방법 중 하나가 네트워크 장비에서 제공하는 flow 정보를 이용하는 방법이다. 하지만 이는 네트워크 장비의 과부하 발생, 운용비용 상승, 유연성 및 확장성 부족의 단점을 가진다. 이를 극복하기위하여 본 논문에서는 Enterprise 네트워크에 적합한 Flow 기반 실시간 트래픽 모니터링 시스템의 구조를 제안하고, 검증을 위해 구현한 내용을 기술한다. 본 시스템은 패킷을 수집하여 실시간으로 flow 정보를 생성하고 저장하는 Flow Generator 시스템, 저장된 flow 정보를 Analysis 시스템으로 전송하는 Flow Exporter 시스템, Traffic Analysis 시스템, 그리고 분석된 내용을 보여주는 Traffic Reporter 시스템으로 구성된다. 본 시스템은 다양한 분석 목적에 맞게 Flow 정보를 조절할 수 있는 유연성과 다양한 분석시스템을 구축할 수 있는 확장성을 가진다. 본 논문에서 기술한 시스템은 학교 Campus 네트워크를 대상으로 구축되었다.

  • PDF

Fluidic oscillation characteristics of plastic flow meter with the variation of cross-sectional shape of splitters (스플리터 단면형상변화에 따른 플라스틱 유량계의 유동진동특성)

  • Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.15 no.2
    • /
    • pp.56-62
    • /
    • 2021
  • In this study, design technology of a non-mechanical flow meter using fluidic oscillation generated during the fluid flow in the chamber was investigated. To with respect to design a splitter, which is the most important factor in fluid oscillation, a transient flow simulation analysis was performed for three types of shapes and changes in inlet flow velocity. The oscillation characteristics with respect to the time in each case were compared, and it was confirmed that the SM03 model was the best among the presented models. In addition, the FFT analysis of the fluid oscillation results for the SM03 model was used to obtain a linear correlation between the flow velocity change and the maximum frequency, and a frequency of 20.957 (Hz/m/s) per unit flow velocity was obtained. Finally, injection molding simulation and molding experiment of the chamber with the designed splitter were performed.

Comparison between CFD analysis and experiments according to various PEMFC flow-field designs (유로 형상 변화에 따른 CFD 해석 결과와 PEM 연료전지 성능 비교)

  • Lee, Kang-In;Park, Min-Soo;Lee, Se-Won;Chu, Chong-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.572-575
    • /
    • 2008
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in four kinds of flow-field designs without additional measurement equipment, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, the performance values of PEMFC according to the flow-field configurations were measured via a single cell test. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. So, the single serpentine configuration gave the highest performance. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.

  • PDF

Aerodynamic Load Analysis for Wind Turbine Blade in Uniform Flow and Ground Shear Flow (균일 흐름과 지상 전단 흐름에 놓인 수평축 풍력터빈 블레이드의 공력 하중 비교)

  • Kim, Jin;Ryu, Ki-Wahn
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.387-390
    • /
    • 2007
  • Recently the diameter of the 5MW wind turbine reaches 126m, and the tower height is nearly the same with the wind turbine diameter. The blade will experience periodic inflow oscillation due to blade rotation inside the ground shear flow region, that is, the inflow velocity is maximum at uppermost position and minimum at lowermost position. In this study we compare the aerodynamic data between two inflow conditions, i.e, uniform flow and normal wind profile. From the computed results all of the relative errors for oscillating amplitudes increased due to the ground shear flow effect. Especially My at hub and $F_x$, $M_y$, $M_z$ at LSS increased enormously. It turns out that the aerodynamic analysis including the ground shear flow effect must be considered for fatigue load analysis.

  • PDF

Study on Risk Analysis of Debris Flow Occurrence Basin Using GIS (GIS를 이용한 토석류 발생유역 위험성분석에 관한 연구)

  • Jun, Kye-Won;Oh, Chae-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.83-88
    • /
    • 2011
  • Annually, many parts of the Korea have been damaged from the localized heavy rain and/or typhoons which peak between June and September, which result in extensive financial and human loss. Especially, because the most area of Gangwon province is composed of the steep slope mountains, the damages by the debris flow or land-sliding are more frequent and the frequency has been increased. To analyze the characteristics and causes of these debris flow disasters, lots of study are recently being conducted through database of weather, hydrologic, soil etc using a GIS or remote sensing. In this study, we applied GIS method to analyze the risk of the debris flow area. With the statistical analysis and infinite slope stability model(SINMAP), the debris flow risk level of the mountain slope was generated. As a result, the GIS statistical analysis showed high correlation that former model of SINMAP in determining the debris flow risk area.

Friction Welding Analysis of Welding Part Shape with Flow Gallery by Friction Welding (마찰용접에 의해 유동부를 갖는 용접부 형상의 마찰용접해석)

  • Yeom S. H.;Nam K. O.;Yoo Y. S.;Hong S. I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.109-112
    • /
    • 2005
  • Friction welding is welding method to use frictional heat of two material. A defect of friction welding is that create flash. The flash is part that must have cut after welding finished. But the welding part with flow gallery by friction welding can't cut flash. Therefore the welding part with flow gallery was designed with no effect in flow. In this research, decide the welding shape parameter of welding part with flow gallery and do friction welding analysis. In friction welding analysis, must input necessary S-S curve, friction coefficient by temperature change, upset pressure, RPM etc. According to analysis result, decided the optimal shape of welding part with no effect in flow.

  • PDF

Mechanism analysis on fluidelastic instability of tube bundles in considering of cross-flow effects

  • Lai, Jiang;Sun, Lei;Gao, Lixia;Li, Pengzhou
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.310-316
    • /
    • 2019
  • Fluidelastic instability is a key issue in steam generator tube bundles subjected in cross-flow. With a low flow velocity, a large amplitude vibration of the tube observed by many researchers. However, the mechanism of this vibration is seldom analyzed. In this paper, the mechanism of cross-flow effects on fluidelastic instability of tube bundles was investigated. Analysis reveals that when the system reaches the critical state, there would be two forms, with two critical velocities, and thus two expressions for the critical velocities were obtained. Fluidelastic instability experiment and numerical analysis were conducted to obtain the critical velocity. And, if system damping is small, with increases of the flow velocity, the stability behavior of tube array changes. At a certain flow velocity, the stability of tube array reaches the first critical state, a dynamic bifurcation occurs. The tube array returns to a stable state with continues to increase the flow velocity. At another certain flow velocity, the stability of tube array reaches the second critical state, another dynamic bifurcation occurs. However, if system damping is big, there is only one critical state with increases the flow velocity. Compared the results of experiments to numerical analysis, it shows a good agreement.