유동 덮개 형상이 축소 APR+ 내부 유동분포에 미치는 영향에 대한 수치해석 (Numerical Analysis for the Effect of Flow Skirt Geometry on the Flow Distribution in the Scaledown APR+)

  • 이공희;방영석;우승웅;김도형;강민구
    • 설비공학논문집
    • /
    • 제25권5호
    • /
    • pp.269-278
    • /
    • 2013
  • In this study, in order to examine the applicability of computational fluid dynamics with the porous model to the analysis of APR+ (Advanced Power Reactor Plus) internal flow, simulation was conducted with the commercial multi-purpose computational fluid dynamics software, ANSYS CFX V.14. In addition, among the various reactor internals, the effect of flow skirt geometry on reactor internal flow was investigated. It was concluded that the porous model for some reactor internal structures could adequately predict the hydraulic characteristics inside the reactor in a qualitative manner. If sufficient computation resource is available, the predicted core inlet flow distribution is expected to be more accurate, by considering the real geometry of the internal structures, especially located in the upstream of the core inlet. Finally, depending on the shape of the flow skirt, the flow distribution was somewhat different locally. The standard deviation of the mass flow rate (${\sigma}$) for the original shape of flow skirt was smaller, than that for the modified shape of flow skirt. This means that the original shape of the flow skirt may give a more uniform distribution of mass flow rate at the core inlet plane, which may be more desirable for the core cooling.

우리나라 하천유역 환경변화가 유황특성에 미치는 영향 분석 (Analysis of Flow Duration Characteristics due to Environmental Change in Korea River Basin)

  • 이재준;김영준
    • 한국방재학회 논문집
    • /
    • 제11권1호
    • /
    • pp.67-75
    • /
    • 2011
  • 본 연구에서는 우리나라의 남해안 및 서해안으로 유입되는 주요 하천인 낙동강, 섬진강, 금강을 대상으로 다목적 댐 건설과 같은 하천환경의 변화가 하천의 상 중 하류부에 미치는 영향에 대하여 검토하기 위하여 비교적 수위자료와 수위-유량곡선 자료가 잘 구비되어 있으며, 자료의 보유년수, 관측개시일 등 양질의 자료가 축적되어 있는 지점을 대상으로 다목적 댐의 건설 시점을 기준으로 유황분석을 실시하였다. 유황의 변화를 분석한 결과 낙동강 중류부에 위치한 적포교 지점을 제외한 모든 지점에서 풍수량, 평수량, 저수량, 갈수량이 증가한 것으로 나타났으며, 하류부의 유황개선효과가 중 상류부에 비해 큰 것으로 나타났다. 하상계수와 유황계수 또한 감소된 것으로 나타났으나 유황계수의 감소폭은 하상계수에 비해 작게 나타났다. 이는 유황계수가 유량의 극치값에 대한 영향을 하상계수에 비해 작게 받기 때문인 것으로 사료되며, 본 연구를 통해서 중 상류부에 위치한 다목적 댐의 긍정적인 효과를 확인할 수 있을 것이라 판단된다.

Gravity Level Dependency of Gas-Liquid Two-Phase Flow

  • Choi, Bu-Hong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권4호
    • /
    • pp.487-493
    • /
    • 2003
  • More reliable design of thermal transport. Power acquisition and thermal management systems requires the through understanding of the flow hydrodynamic. the differences and similarities between the two-phase flow characteristics of two-Phase flow influenced by the gravity levels. The data of flow Patterns, void fraction, frictional pressure drop associated with their characteristics were obtained at $\mu\textrm{g}$. 1g and 2g. Flow patterns and void fraction data obtained at three gravity levels were compared with each other and previous models and correlations.

재생펌프의 누설 유동 및 내부 유동에 관한 연구 (Study on the Leakage Flow and the Flow Analysis of Regenerative Pump)

  • 심창열;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.593-596
    • /
    • 2002
  • Flows in a regenerative pump were calculated for several flow-rates, using the CFX-Tascflow. The calculated results show the vortex structure in the impeller and side channel. The predicted performance shows considerable discrepancy form the measured values for low flow rates. Main source of the difference is the leakage flow of pump strongly affecting the performance of pump. A simple correlation was proposed using calculated leakage flows through the parametric calculations of the simplified passage.

  • PDF

미소중력하의 기액이상류의 유동양식 (Flow Patterns of Gas-Liquid Two-phase Flow under Microgravity)

  • 최부홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.460-465
    • /
    • 2003
  • Microgravity experiments were conducted to determine the effect of liquid and gas superficial velocities on flow behaviors. Flow behaviors observed under microgravity conditions can be classified into five flow patterns: bubble. Taylor bubble, slug, semi-annular and annular flows. Transition boundary between four flow patterns could be determined by drift-flux model. It was also found that the effect of gravity and pipe inclination on flow pattern transition was not significant in the inertia dominant region.

운동입구에서의 컬러도플러유동매핑: 근위유동수렴 (Color Doppler Flow Mapping of a Moving Orifice: Proximal Flow Convergence)

  • 김영호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.39-42
    • /
    • 1992
  • Color Doppler flow mapping (CDFM) was performed on an $\underline{in\;vitro}$ experimental setup with a regurgitant moving orifice using the proximal isovelocity surface area (PISA) technique. PISA flow rates underestimated actual flow rates by as much as 65%, which is very important in diagnosing patients with valvular regurgitations or stenosis. The correction factor considering the velocity of the orifice improved the PISA flow rates.

  • PDF

신호 흐름 그래프에 의한 샘풀된 데이터계통의 해석 (Analysis of Sampled-data Systems by Signal Flow Graphs)

  • 박상희
    • 전기의세계
    • /
    • 제19권5호
    • /
    • pp.1-7
    • /
    • 1970
  • Starting from the review of signal flow graphs and flow graphs, this paper gives an example of sampled-data systems for Sedlar & Bekey's formulation. In this purpose it discussed the difference between Mason's signal-flow graphs and Coates flow graphs for drawing th flow graph of a linear system, and then a new flow-graph symbol introduced in order to distinguish between continuous and discrete systems. Thus, the paper is analysed and compared with a sampled-data systems between conventional methods and new method of signal flow graphs.

  • PDF

DBD (Dielectric Barrier Discharge)를 이용한 유량 센서 개발에 관한 연구 (Development of a Flow Sensor Using DBD (Dielectric Barrier Discharge))

  • 김태훈;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2076-2081
    • /
    • 2008
  • In this study, a new concept of a flow sensor is developed using dielectric barrier discharge (DBD). Current of DBD generated between two electrodes is changed with varying flow rates. Therefore, it is possible to measure the flow rate by correlating generated DBD current with flow rates. The effects of flow rate, frequency, channel height, diameter of electrodes and distance between electrodes on the performance of the flow sensor using DBD are experimentally investigated.

  • PDF

Flow separator가 부착된 수직벽 후류유동의 실험적 연구 (Experimental study of vertical fence wake with flow separator)

  • 최영호;김형범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.68-72
    • /
    • 2006
  • Vertical fence has the coherent flow structure in front of the fence. In the present study, the wake change due to the flow separator in front of the vertical fence was experimentally investigated. Quantitative method was applied to study the separated shear flow field. The results show the flow separator changes the downstream shear flow and alters the curvature of separated shear layer As the freestream velocity increased, the reattachment length also increased.

  • PDF

CFD를 활용한 축류형 혈액펌프의 펌프 특성 해석 (Pump performance analysis of Axial Flow Blood Pump using CFD)

  • 최승한;김동욱
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.288-290
    • /
    • 2003
  • Artificial heart is divided by pulsation flow type and continuous flow type according to blood circulation pattern. Axial flow blood pump is a kind of continuous flow type artificial heart. Axial flow blood pump would be different pump performance according to impeller's shape and rotating velocity. Pump performance be able to compare by flow rate according to differential pressure and Impeller's rotating velocity. It confirms Impeller model of better efficiency according to compare Pump performance of axial flow blood pump using CFD with actual experiment result.