• Title/Summary/Keyword: flooring

Search Result 206, Processing Time 0.029 seconds

Analysis of Suitability of Oriented Strand Board(O.S.B) as a Flooring Board (플로어링보드용으로서 배향성스트랜드보드(O.S.B)의 적합성 분석)

  • Shin, Sang-Ho;Park, Cheul-Woo;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.213-214
    • /
    • 2019
  • Oriented strand board(O.S.B) is used in many areas, such as interior and interior finishes of wooden houses, but no cases and studies have been used as flooring materials for flooring boards. In this study, we will examine the quality and performance of the aromatic strands board, which we believe can be substituted for the plywood, and analyze its suitability as a floorboard.

  • PDF

Analysis of Surface Heat Characteristics by Decoration Wood-based Wood Flooring Board (치장목질마루판 종류별 표면열전달성 분석)

  • Park, Cheul-Woo;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.171-172
    • /
    • 2017
  • There is some recognition that Decoration Wood-based Flooring Board in Korea is a material that inhibits the heat transfer from the substrate to the room. There is a lack of substantial research literature on the surface heat transfer and condition of Decoration Wood-based Flooring Board, which is insufficient to deal with false perceptions. In this study, the purpose of this study is to analyze the surface heat transfer characteristics of Decoration Wood-based Flooring Board and to obtain basic data to cope with recognition.

  • PDF

A Study on the Analysis of the Combustion Behavior and Carbonization Pattern of Vinyl Flooring on Which a Real-Scale Combustion Test Was Performed (실물 연소 실험이 진행된 비닐장판의 연소거동 및 탄화 패턴 해석에 관한 연구)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.120-125
    • /
    • 2019
  • A real-scale combustion test was conducted on a vinyl flooring in a divided space, with 50 mL of an inflammable liquid sprayed on it. The combustion behavior of the vinyl flooring was studied in real time, and the carbonization patterns of the surface and cross-sections of the carbonized vinyl floor were analyzed. When the flame ignited by gasoline reached its peak, a continuously flaming region, intermittent flaming region, plume region, etc., were formed. The combustion of 50 mL gasoline on vinyl flooring took 26 s, and a halo pattern was observed. This test involved spraying kerosene evenly on the vinyl flooring and attempting to ignite the flooring using a gas torch, which failed. After the combustion of the vinyl flooring was complete, its carbonized range was measured to be 600 mm in length and 380 mm in width, and the carbonized area was 1000 ㎟. Heat transformed the coated layer of surface of the carbonized vinyl flooring into a carbonized layer, which became harder. The analysis of cross-section of the boundary surface of the carbonized vinyl flooring using a stereoscopic microscope showed that the vinyl flooring was bubbling, and that the white boundary layer at the bottom of the coated layer had disappeared.

A Study on Pollution Conditions and Management of Sand Flooring Related to Animal Feces - Nitrogen Analysis Method Development - (동물 분변으로 인한 모래 바닥재의 오염실태 및 관리 방안에 관한 연구 - 질소분석방법개발 -)

  • Jeong, Won-Gu;Ha, Ji-Young;Oh, Geun-Chan;Huh, In-Ryang;Choi, Seung-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.646-654
    • /
    • 2020
  • Objectives: Users of parks or children's play facilities have pointed to pets' bowel movements as the most serious problem when using them. In prior studies, a very low detection rate of parasites (eggs) in sand flooring materials has been found. Even though feces have been identified, no parasites (eggs) have been detected. Method: A standard solution of nitrate nitrogen was used to verify the reliability of a new nitrogen analysis method. The linearity, precision, and accuracy of the nitrate nitrogen analysis method were verified. Using this method, the pollution distribution of the sand flooring material and the degree of pollution at each point were investigated. Results: As a result of the verification of the nitrogen analysis method, the linearity was found to be good at r2=0.999 when distilled water is mixed in a standard substance solution. The standard substance additive solution r2=0.968 was found to be good. Precision represented 0.01 to 0.06% RSD for peak height. The recovery rate was 92.4 to 104.0 percent, indicating high accuracy. According to the same method of analysis, the flooring material sand at a general amusement facility with the largest number of concealed spaces was nitrate nitrogen 6.1 times higher than at the entrance of the playground. Also, in a comparison between clean sand and sandy flooring, the average nitrogen concentration of the sand flooring material was 24.4-167 times higher than pure sand. Conclusions: As such, no parasites (eggs) were detected at all points under investigation, but the sand flooring was exposed to animal fecal contamination. Therefore, the management of nitrogenous components should allow accurate identification of animal fecal contamination so that the timing of sand replacement can be managed hygienically and safely.

Characteristics for VOCs and aldehydes emission rates from architectural flooring (건축용 바닥재로부터의 VOCs와 Aldehydes 방출 특성)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Seo, Soo-Yun;Lee, Woo-Suk;Lim, Jun-Ho;Lim, Jeong-Yun
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.544-552
    • /
    • 2006
  • Emission tests were carried out to investigate the characteristics of concentration according to flooring sort using small chamber method. The target Volatile Organic Compounds (VOC) included 27 individual compounds of environmental concern, which were determined by adsorption sampling and thermal desorption coupled with GC/MS method and by DNPH cartridge/HPLC method. The emission factor of Total Volatile Organic Compounds (TVOC) and Formaldehyde (HCHO) was detected $0.3mg/m^2{\cdot}h$ and $0.2mg/m^2{\cdot}h$ respectively, and the floorings of 37 (9 PVC Tile, 10 PVC Sheet, 18 Flooring) were satisfied emission standard. TVOC emission factor appeared in order of concentration of PVC Sheet, PVC Tile, and floor flooring, while HCHO was detected very high emission factor (as $0.4mg/m^2{\cdot}h$) at floor flooring above PVC series (as $0.001mg/m^2{\cdot}h$).

Performance evaluation of MPCM to apply for radiant floor heating system (바닥난방시스템 적용을 위한 MPCM 성능평가)

  • Jeong, Su-Gwang;Jeon, Ji-Soo;Kim, Su-Min
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.475-479
    • /
    • 2012
  • Thermal energy storage (TES) systems using Microencapsulated phase change material (MPCM) have been recognized as one of the most advanced energy technologies in enhancing the energy efficiency and sustainability of buildings. We examined a way to incorporate MPCMs with building materials through application for wood-based flooring. Wood-based flooring is commonly used for floor finish materials of residential buildings in Korea. However, wood-based flooring has not performed the characteristic of heat storage. This study is aimed at manufacturing high thermal efficiency wood flooring by increasing its heat storage using MPCM. As a result, this study confirmed that MPCM is dispersed well in adhesive through the scanning electron microscopy analysis. From the differential scanning calorimetry analysis, it can be confirmed that this composite has the characteristic of a thermal energy storage material. Also, we analyzed how this composition was formed by physical combination through the Fourier transform infrared analysis. Also, we confirmed the bonding strength of the material by using the universal testing machine.

  • PDF

A Study on Heat Transfer of Plywood for Wood Based Flooring by Veneer Composition (마루판용 합판의 단판 구성요소에 따른 열전달 특성에 관한 연구)

  • Pi, Duck-Won;Choi, Song-Kyu;Kang, Ho-Yang;Kang, Seog-Goo
    • Journal of the Korea Furniture Society
    • /
    • v.23 no.3
    • /
    • pp.298-304
    • /
    • 2012
  • Since 1990's, a flooring based on plywood has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as a core layer was checked by heat transfer experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on heat transfer are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are 'M' type of density gradient on the other hand Eucalyptus samples are 'W' type of density gradient.

  • PDF

The Review on reducing slip and other hazards on flooring materials for station (철도역사내 보행위험 방지를 위한 보행로 재료에 관한 고찰)

  • Kim, Jin-Ho;Kim, Min-Hee
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.558-563
    • /
    • 2007
  • Walking passenger injury accidents in and around stations have increased in recent years, and passengers are now more aware of being able to claim compensation for such accidents. Therefore, it is anticipated that station managers and owners will need to take measures to improve the condition of walking areas so that performance objectives are met an the compensation paid for passenger accidents is limited. The aim of this study covers the following: accidents statics and contributory factors, station flooring and footway material, guidance for flooring, and test methods for slipperiness and surface profile.

  • PDF

Surface Properties of Wood-Based Floorings for Under Heating Systems (Ondol) (온돌용 목질마루판의 표면물성)

  • 김종인;박종영;이병후;김현중
    • Journal of the Korea Furniture Society
    • /
    • v.13 no.1
    • /
    • pp.27-37
    • /
    • 2002
  • This study was investigated with the surface properties such as physical and accelerated tests of wood-based floorings. In physical test, hardness and abrasion resistance values of laminate floorings were higher than those of others. The center line average surface roughness($R_a$) of imported laminate flooring was highest value($1.34{\mu}m$) and that of imported solid wood flooring was lowest value($0.62{\mu}m$). In cold resistance and moist heat resistance, no defects were found on the surface of all flooring (crack, blistering, peeling, and gloss loss etc.) after testing. Wet-cold-dry cycle test showed that plywood flooring appeared some cracks. In accelerated weathering test, color difference increased with increasing Xenon arc light irradiation

  • PDF

The Coating Performance of UV Curable Urethane Acrylate Coatings for Fancy Veneer Overlayed Plywood Flooring

  • Lee, Byoung-Hoo;Kim, Hyun-Joong;Lee, Young-Kyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.23-35
    • /
    • 2004
  • The goal of study was to investigate the influence of the acrylated urethane oligomer on mechanical properties, the chemical resistance and thermal resistance of the UV curable urethane acrylate coatings for fancy veneer overlayed plywood flooring. The pencil hardness and abrasion resistance of the coated fancy veneer overlayed plywood floorings increased with increasing the acrylate functionality of the acrylated urethane oligomer. In the case of the UV cured film containing hexa-functional acrylated aliphatic urethane oligomer, high discoloration of the coated fancy veneer overlayed plywood flooring was observed near the cracks at the beginning of the chemical treatment. In this study, it was found that the degradation of the UV cured film caused by an alkaline reagent was higher than that of the UV cured film caused by an acidic treatment.