An Experimental Study on the Thermal Performance of Cement Mortar with Granulated PCM

  • Jeong, You-Gun;Park, Ki-Bong;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.5
    • /
    • pp.548-557
    • /
    • 2012
  • In this study the thermal performance of G-PCM replaced for find aggregate in mortar specimens was evaluated using TG-DTA. As a result, it was found that when solid changed into liquid, it absorbed heat, and when liquid changed into solid, it radiated heat. In addition, the fluidity and the compressive strength of mortar with G-PCM can be applied to the floor mortar and a wall finish material. Also the higher the replacement ratio, the larger the latent heat capacity. It was found that the mortar with G-PCM slowed the increase and decrease of temperature. Thus, the duration of pleasant indoor temperature is extended by the floor and wall mortar with G-PCM. In conclusion, G-PCM is expected to reduce the heating energy consumption.

An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구)

  • 김용이;임재한;한여명;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

Temperature monitoring and seasonal borehole heat exchange rate characteristics of a geothermal heat pump system (지열 히트펌프 시스템의 계절별 지중 열교환 특성 및 지반내 온도 변화)

  • Shim, Byoung-Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.452-455
    • /
    • 2007
  • The geothermal heat pump system is designed for cooling and heating for three stories building (2,435 $m^2$) includes total 79 heat pumps. Therefore, the monitoring system is installed for each floor and the data is automatically transmitted to the monitoring system. Heat exchange rate and temperature of a geothermal heat pump system have been monitored for a long period. The seasonal operation of geothermal heat pump shows the different shape of heat exchange rate for cooling and heating. Ground water flow can influence on heat exchange rate and thermal storage of the system. In order to define the hydraulic characteristics and groundwater temperature variation, the relationships among air temperatures, groundwater temperatures, water table, and precipitation are analysed.

  • PDF

Distribution of Pollutant on the Indoor Air of Passenger Car (철도차량 객차내 오염물질의 분포경향에 관한 전산해석)

  • So, Jin-Sub;Chun, Chul-Kyun;Park, Chan-Su;Choi, Ju-Seok
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.2
    • /
    • pp.7-16
    • /
    • 2003
  • The transfer of air pollutants between passenger room and service room in train are investigated by the computational analysis. The effects of service room temperature, inlet velocity, initial concentration and heating are studied. The flow induced by the difference of density between two rooms is found to take the major role in transfer of polluted air. Low temperature of service room enhances the polluted air flow into passenger room along the floor. Exhaust fan above the door between two rooms is not effective for this case. Strong inlet flow is found to suppress polluted air flow from service room. The heating of passenger room can promote air pollution.

  • PDF

The change of Kitchen in a Single Detached House in Jeonju City after 70's through Oral Life History method (구술로 본 1970년대 이후 전주지역 단독주택 부엌의 변화)

  • Park, Sun-Hee
    • Journal of the Korean housing association
    • /
    • v.17 no.6
    • /
    • pp.55-63
    • /
    • 2006
  • The purpose of this study is to investigate the change of kitchen in a single detached house in Jeonju city after 70's. Oral life history method which has 12 women's personal narratives and 17 women's personal narratives with written reports was used as a research method of this study. The results of the study were obtained as follows: 1) It was beginning about late 1970 year that heating system and cooking place were separated in a house. 2) Many kitchens were reconstructed for indoor stand-up work place from late 1970's to the early 1980's. 3) There were major factors such as heating system, cooking fuel, and work center in the change of kitchen in old houses. 4) The kitchen toward the center with a living room was appeared in the floor plan of modem house after 1990's. The symbolic words of the indoor kitchen that work for women were 'warmness' and 'convenience'.

A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy (지열 이용 외기부하 저감시스템의 냉각 및 가열효과 예측 간이추정법에 관한 연구)

  • Son, Won-Tug;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.3
    • /
    • pp.169-181
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

  • PDF

Analysis on Economic Feasibility of Electric Night Storage Heat Pump as a Substitution of a Heater (심야전기보일러 대체 Heat Pump의 경제성 분석)

  • JUNG, H.;JO, J.Y.;Lee, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.119-124
    • /
    • 2011
  • Electric night storage heater was introduced and disseminated for power grid balancing and efficient management of power generation facility. But fuel cost for heating has been increased rapidly while the cost of electricity increased slightly. This abnormal rate system caused peak load in winter at last. To solve this problem, application of an air source heat pump was suggested. In the study, the effect of replacing night heater by heat pump and the economics were analysed. In addition the expectation of prospect of heat pump penetration was simulated based on surveyed and investigated data. As a result, fund supporting as well as institutional backing was needed for effective propagation and return of investment.

Experiment and Property Study of Ondol Panel Based on Phase Change Material (PCM을 이용한 온돌패널의 실험 및 특성연구)

  • Yoon, Doo-Han;Choi, Bong-Su;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.122-125
    • /
    • 2006
  • This paper deals with the Ondol, Korean under-floor heating system using latent heat storage materials. It has been recognized that the heating system using the latent heat storage materials are economically efficient and comfortable. For the comparison and analysis to the data of the existing experiment, a repetitive experiment makes sure the ability of Ondol panel.

  • PDF