• 제목/요약/키워드: floor

검색결과 6,094건 처리시간 0.03초

분리된 천정의 설치를 통한 목구조 바닥의 내화성능 및 충격음 차단성능 향상 (Improvement of Fire Resistance and Impact Sound Insulation Performance for Timber Framed Floor by Installation of Isolated Ceiling)

  • 박주생;김세종;이상준
    • 한국가구학회지
    • /
    • 제24권4호
    • /
    • pp.426-432
    • /
    • 2013
  • Fire resistance and impact sound insulation tests were performed for a floor assembly, of which stiffness was reinforced by shortening the span of floor joists by installing glulam beam additionally in the middle or one thirds of the original span, and which an additional ceiling component was installed apart from floor structure. By applying the isolated ceiling, timber framed floor showed 1 hour of fire resistance even in case that dead load was increased by considering cement mortar layer for radiant floor heating. Insulation performance against light and heavy impact sound was improved significantly by applying the sound absorbing layer of big mass and high elasticity in addition to the stiffness improvement and isolated ceiling.

  • PDF

바닥마감재가 경량충격음 저감량 평가에 미치는 영향 (A Study on the Reduction of the Lightweight Impact Sound Level by Floor Coverings)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.137-142
    • /
    • 2004
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by floor coverings. The characteristics on the reduction of the lightweight impact sound level by floor coverings is as follows. The insulation level attained by floor coverings tends to be smaller in actual buildings than in public laboratories. The reduction of the impact sound level to the tape is similar to the method of adhesives. For this reason, the reduction of impact sound level by floor coverings in public laboratories can be utilized to tape. And the reduction of impact sound level by floor coverings is not influenced by the size of specimen except the specific frequency.

  • PDF

공동주택 바닥충격음의 차음성능 평가 (Evaluation of Floor-Impact Sound Insulation for Apartment Buildings)

  • 윤세철;오종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.932-937
    • /
    • 2003
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among accupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for seven apartment buildings. The floor-impact sound levels were measured for seventeen On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

  • PDF

공동주택의 층별 도로교통 소음의 전달 특성에 관한 연구 (A Study on the Floor-Specific Characteristics of Road Traffic Noise in Apartment Buildings)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2008
  • This study is an attempt to understand the floor-specific characteristics of facade road traffic noise in apartment buildings. For this purpose, it sampled a total of seven roadside apartment building complexes: three with no soundproof bar barrier installed at roadside, one with a forest buffer zone, one with a sound-absorbing hill, and two with soundproof barriers. The measured noise level was highest on the 5th floor of apartment buildings with no soundproof barrier, and the upper stories from the 5th floor showed lower-noise measurements in order. For apartment buildings with soundproof barriers, however, the noise level was lower on the 10th floor than the 5th floor. Two apartment building groups--one with a sound-absorbing hill and the other with no soundproof barrier--showed similar measurement results in the floor-specific characteristics of facade road traffic noise. This suggests that such installations have little sound insulation effect. In the apartment building complex with a forest buffer zone around it, a slight sound insulation effect was measured on the lower floors of the buildings.

건식 이중바닥구조의 중량충격음 저감성능 평가 (Evaluation for The Heavy-weight Impact Sound Reduction Performance of Dry Double-Floor System)

  • 연준오;김경우;최현중;양관섭;김경호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.280-285
    • /
    • 2012
  • The 1st assessment (performance test) was applied to assure the floor impact sound performance for developing the dry double- floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in substructure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5dB. Based on this result, the 2nd assessment (performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry doublefloor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPE-11 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPE-11 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

  • PDF

재실자의 평균피부온(平均皮膚溫)에 관한 연구 (A Study on the Mean Skin Temperature of the Man Who Stay in the Room)

  • 최영식
    • 한국산업융합학회 논문집
    • /
    • 제3권4호
    • /
    • pp.307-317
    • /
    • 2000
  • The purpose of this study is to form a calculation formula of the mean skin temperature on the human body in a heated room by the use of floor heating system. Korean traditional floor heating system is a long way from being defunct. The floor heating systems based on hot water have been coming into wide use mainly in the apartment house. However, it is considered that the design process and evaluation method for the floor heating systems in the standpoint of human being are not established so far. In the floor heating systems, air temperature as well as floor temperature should be considered as physical factors which affect the sensation of human body. Furthermore, extremely few studies have been performed on the sitting with legs crossed posture sedentary which is the typical dwelling life style of residents from the ancient times in Korea, while a large number of studies on the influence of the floor heating systems on the human body in standing and sitting on a chair sedentary have been carried out. Especially, it is essential to elucidate how mean skin temperature on the human body is affected by thermal conduction in the contact area between the sitting with legs crossed posture sedentary human body and floor including thermal radiation due to the combination of air temperature and floor temperature, but the studies dealt with such issues have hardly been performed. Based on the above statements, the influence of the environment condition due to the combination of air temperature and floor temperature is discussed in the present investigation through theoretical of mean skin temperature on the human body in the floor heating systems.

  • PDF

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

고탄성 특성을 보유한 친환경 우븐 바닥재에 관한 연구(II) - TPU 코팅사 및 바닥재의 특성- (Development of Eco-friendly Woven Floor Mat with High Resilience II - Characterization of TPU Coating Yarn and Floor Mat -)

  • 이선희
    • 한국의류산업학회지
    • /
    • 제14권4호
    • /
    • pp.635-640
    • /
    • 2012
  • In this study, thermoplastic urethane (TPU) coating yarns were prepared at various extruding temperatures. The fine structure and mechanical properties of resultant TPU coating yarns examined by the wide angle X-ray diffractometer (WAXD), differential scanning calorimetry (DSC), dynamic mechanical thermal analysis (DMTA), and tensile test. TPU coating yarns (prepared at extruding temperatures at $175^{\circ}C$) were confirmed as a stable fine structure that obtained excellent tensile strength and flexibility. The C samples prepared by optimized conditions made by TPU woven floor mat. The structure of the woven mat is $4{\times}4$ basket weave and have laminated with the EVA foam to obtained final TPU woven floor mat products. The resultant TPU woven floor mat was obtained to 1.5MN of tensile strength, 22% of the elongation, and 0.2MN of tear strength. The weight loss abrasion and the resilience by the ball rebound of the TPU-woven floor mat was prior to those of the PVC subsequently, we were able to develop a woven floor mat with TPU coating yarn and produce an eco-friendly high valuable woven floor mat using an interior product.

데크 바닥판 구조물의 실용적인 진동해석 (Practical Vibration Analysis of Deck Floor Slab)

  • 김기철
    • 한국전산구조공학회논문집
    • /
    • 제18권1호
    • /
    • pp.61-69
    • /
    • 2005
  • 장경간화되고 경량화된 데크 바닥판 구조물은 부재가 유연하기 때문에 거주자의 움직임에 의하여 진동이 크게 발생할 수 있으며, 이러한 바닥판 진동은 건축물의 안전성뿐만 아니라 건축물의 사용성에도 많은 영향을 끼치므로 건축물의 품질 평가기준으로 사용되고 있다. 데크 바닥판 구조물의 올바른 사용성 평가를 위해서는 정확한 진동해석과 응답평가가 수반되어야한다. 본 논문에서는 데크 바닥판 구조물의 직교이방성을 고려한 여러 가지 모형화 방법을 적용하여 진동해석을 수행하였으며 모형화 방법에 따른 진동응답을 비교 분석하였다. 본 논문에서 제시한 데크 골 방향 강성에 대한 등가두께 모형화방법은 간단한 방법으로 데크 바닥판 구조물의 직교이방성을 간단한 방법으로 고려할 수 있으며, 정확한 진동응답을 얻을 수 있으므로 실무에서 실용적으로 활용할 수 있다.

Identification of scheduling problems for CSCW-based shop floor control in agile manufacturing

  • Cha, Soohyun;Cho, Hyunbo;Jung, Mooyoung
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1995년도 춘계공동학술대회논문집; 전남대학교; 28-29 Apr. 1995
    • /
    • pp.208-215
    • /
    • 1995
  • Numerous solution methods for scheduling problems such as part dispatching problem, operation sequence problem have been suggested as a means to be embedded in hierarchical or centralized shop floor control. Under the preceding control philosophies, however, response to changes in the shop floor status is quite slow and timely decision is sometimes impossible. Moreover, the control software becomes too large and it is almost impossible to modify the control software when the configuration of the shop floor changes. In agile manufacturing which emerged recently to cope with quick response and easy modifiability when unexpected changes occur, a new control policy is needed. CSCW[Computer Supported Cooperative Work] based shop floor control casts a different view on scheduling problems. Decisions are made locally when requested and useful information is scattered among agents for its efficient use. Adaptation is easy because agents are -'plug compatible or portable. In this paper, scheduling problems occurring under CSCW based shop floor control are identified and characterized. Traditional scheduling problems are reviewed from the CSCW viewpoint. All the control entities involved in the shop floor can be found and used to defined agents. With these entities and CSCW concept, possible scheduling problems are identified.

  • PDF