• 제목/요약/키워드: flexural reinforcement ratio

검색결과 281건 처리시간 0.037초

Strategic Utilization of Fiber Reinforced UHSC in Slab-Column Connections

  • Yoon, Young-Soo;Lee, Joo-Ha;Lee, Seung-Hoon
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.79-82
    • /
    • 2005
  • This study reports on the structural characteristics of slab-column connections using an ultra-high-strength-fiber-reinforced concrete from new and retrospective data. The parameters investigated were the ' puddling ' of ultra-high-strength-fiber-reinforced concrete and the use of high-strength concrete in the slab. The effects of these parameters on the punching shear capacity, negative moment cracking, and stiffness of the two-way slab specimens are investigated. Furthermore, the ACI Code (2002), the CSA Standard (1994), the BS Standard (1985) and the CEB-FIP Code (1990) predictions are compared to the experimental results obtained from some slab-column connections tested in this experiment and those tested by other investigators. The beneficial effects of the ultra-high-strength-fiber-reinforced concrete puddling and of the use of high-strength concrete are demonstrated. It is also concluded that the punching shear strength of slab-column connections is a function of the flexural reinforcement ratio.

  • PDF

손상된 철근콘크리트 교각의 내진성능평가를 위한 실험연구 (An Experimental Evaluation of Seismic Performancef for Damaged Reinforced Concrete Bridge Piers.)

  • 박창규;이은희;이대형;정영수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.385-392
    • /
    • 2003
  • Experimental investigation was conducted into the flexure/shear-critical behavior of earthquake-damaged reinforced concrete columns with lap splicing of longitudinal reinforcement in the plastic hinge region. Six test specimens in the aspect ratio of 2.5 were made with test parameters: confinement ratios, lap splices, and retrofitting FRP materials. They were damaged under series of artificial earthquakes that could be compatible in Korean peninsula. Directly after the pseudo-dynamic test, damaged columns were retested under inelastic reversal cyclic loading simultaneously under a constant axial load, P = 0.1 $f_{ck}$ $A_{g}$. Residual seismic performance of damaged columns was evaluated and compared to that of the corresponding original columns. Test results show that RC bridge piers with lap-spliced longitudinal steels in the plastic hinge region appeared to fail at low ductility. This was due to the debonding of the lap splice, which resulted from insufficient development of the longitudinal steels. The specimens externally wrapped with composite FRP straps in the potential plastic hinge region indicated significant improvement both in flexural strength and displacement ductility.y.

  • PDF

강섬유와 PVA 섬유로 하이브리드 보강된 콘크리트의 슬럼프 및 역학적 특성 (Slump and Mechanical Properties of Hybrid Steel-PVA Fiber Reinforced Concrete)

  • 양근혁
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.651-658
    • /
    • 2010
  • 콘크리트의 슬럼프와 역학적특성에 대한 마이크로 섬유와 매크로 섬유의 영향을 파악하기 위하여 강섬유와 PVA 섬유로 하이브리드 보강된 콘크리트 16배합과 무보강 콘크리트 1배합을 실험하였다. 주요 변수는 강섬유와 PVA 섬유의 체적비 및 길이이다. 하이브리드 섬유보강 콘크리트의 역학적특성들은 섬유보강지수에 따라 분석되었으며, 강섬유 또는 PVA 섬유만으로 보강된 콘크리트와 비교하였다. 하이브리드 섬유보강 콘크리트의 슬럼프는 섬유 체적비와 형상비 증가와 함께 감소하였으며, 할렬인장강도, 파괴계수, 탄성계수 및 휨 인성지수는 섬유보강지수의 증가와 함께 증가하였다. 단일 섬유보강 콘크리트의 섬유체적비에 비해 낮은 체적비를 갖는 하이브리드 섬유보강 콘크리트의 파괴계수와 휨인성지수는 단일 섬유보강 콘크리트에 비해 높았다. 하이브리드 섬유보강 콘크리트의 휨 인성 향상을 위해서는 30 mm와 60 mm 길이의 강섬유를 함께 사용하는 것보다는 60 mm 강섬유만을 사용하는 것이 효율적이었다.

용접철망을 사용한 반두께 P.C.슬래브의 휨 및 연성거동 (The Flexural Behavior including Ductility of Half Precast Concrete Slab with Welded Deformed Wire Fabric)

  • 이광수;최종수;조민형;신성우
    • 콘크리트학회지
    • /
    • 제6권4호
    • /
    • pp.153-160
    • /
    • 1994
  • 본 연구는 용접철망을 사용한 반두께 프리캐스트 콘크리트 슬래브의 휨내력 평가 및 연성능력 검토를 위하여 총 10개의 일방향 반두께 프리캐스트 콘크리트 슬래브를 제작하여 2점 단순 재하를 하였다. 주요변수로서는 상부콘크리트 압축강도, 반두께 슬래브의 표면거칠기, 그리고 인장철근비로 구성되었으며, 실험결과는 다음과 같다. 반두께 프리캐스트 콘크리트 슬래브의 휨설계는 국내 극한강도 설계법에 의한 슬래브 설계방식의 사용이 가능한 것으로 나타났다. 슬래브에 $4000kg/cm^2$이상의 용접철망을 사용할 경우 기존의 규준에 따라 항복응력도를 변형율 0.0035에 해당하는 응력도를 사용하는 것이 안정적인 것으로 나타났다. 용접철망을 사용한 슬래브의 경우 철근 콘크리트 연성평가에 따라 분석한 결과 연성부담능력이 저하되어 용접철망을 경우에는 연성증진을 위한 일반철근을 혼용하는 것이 바람직한 것으로 판단된다.

Development and evaluation of punching shear database for flat slab-column connections without shear reinforcement

  • Derogar, Shahram;Ince, Ceren;Mandal, Parthasarathi
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.203-215
    • /
    • 2018
  • A large body of experiments have been conducted to date to evaluate the punching shear strength of flat slab-column connections, but it is noted that only a few of them have been considered for the development of the ACI Code provisions. The limited test results used for the development of the code provisions fall short of predicting accurately the punching shear strength of such connections. In an effort to address this shortfall and to gain an insight into the factors that control the punching shear strength of flat slab-column connections, we report a qualified database of 650 punching shear test results in this article. All slabs examined in this database were tested under gravity loading and do not contain shear reinforcement. In order to justify including any test result for evaluation punching shear database, we have developed an approved set of criteria. Carefully established set of criteria represent the actual characteristics of structures that include minimum compressive strength, effective depths of slab, flexural and compression reinforcement ratio and column size. The key parameters that significantly affect the punching shear strength of flat slab-column connections are then examined using ACI 318-14 expression. The results reported here have paramount significance on the range of applicability of the ACI Code provision and seem to indicate that the ACI provisions do not sufficiently capture many trends identified through regression of the principal parameters, and fall on the unsafe side for the prediction of the punching shear strength of flat slab-column connections.

플랫 플레이트의 장단기 처짐에 대한 중공 슬래브의 자중저감 효과 분석 (Analysis of Weight Reduction Effect of Void Slab on Long and Short Term Deflections of Flat Plates)

  • 김재요
    • 한국전산구조공학회논문집
    • /
    • 제30권4호
    • /
    • pp.343-350
    • /
    • 2017
  • RC 플랫 플레이트 시스템은 공기단축, 시공성 향상, 층고 절감 등의 장점이 있으나, 장스팬 적용 시 슬래브의 작은 휨강성으로 인해 균열 손상 및 과다 처짐이 발생하는 경향이 있다. 특히, 시공 중 슬래브 자중에 의한 과하중의 작용이 슬래브의 장단기 처짐을 증가시킬 수 있다. 이러한 문제점은 자중 저감이라는 장점을 갖고 있는 중공 슬래의 사용을 통해 해결할 수 있다. 이 연구에서는 슬래브 처짐에 대한 중공 슬래브의 자중저감 효과를 분석하기 위하여 변수연구를 수행한다. 콘크리트 강도, 슬래브 시공주기, 동바리 지지층수, 압축철근비, 인장철근비 등의 변수조건들을 포함하여, 시공단계, 콘크리트 균열, 장기 효과를 고려한 시공하중 및 처짐을 산정한다. 일반 슬래브와 중공 슬래브에 대한 시공 중 단기처짐과 완공 후 장기처짐을 비교하고, 슬래브 처짐에 대한 중공 슬래브의 효과를 분석한다.

시험방법에 따른 폴리머 시멘트 모르타르의 인장 및 휨접착강도 개선에 관한 연구 (A Study on the Improvement of Adhesion in Tension and Flexure of Polymer Cement Mortar Depending on Various Test Methods)

  • 조영국
    • 한국건축시공학회지
    • /
    • 제19권1호
    • /
    • pp.47-57
    • /
    • 2019
  • 폴리머 종류에 상관없이 폴리머 시멘트비의 증가에 따라 접착성능은 크게 개선되었으며, A타입 인장접착강도는 1.90배, B 타입 인장(접착)강도는 2.17배, 휨(접착)강도는 1.83배 보통 시멘트 모르타르 보다 높게 나타났으며, 보통 시멘트 모르타르의 B 타입 인장(접착)강도에 대한 인장강도비와 휨(접착)강도에 대한 휨강도비인 상대강도비가 각각 46.9%, 72.6%를 나타냈으며, 폴리머 시멘트 모르타르의 경우에는 각각 50.1%~101.7%, 73.8%~132.9% 범위를 나타내, 폴리머 시멘트 모르타르가 높은 강도회복율을 보였다. 폴리머 종류에 따라서는 EVA를 사용하고, 폴리머 시멘트비로서는 접착성능과 경제성을 고려하면, P/C 10%~15% 범위를 제안할 수 있다.

대형보 실험을 통한 TBM 터널 세그먼트용 강섬유보강콘크리트 성능평가 (Performance evaluation of SFRC for tunnel segments based on large beam test)

  • 문도영;노화성;장수호;이규필;배규진
    • 한국터널지하공간학회 논문집
    • /
    • 제16권3호
    • /
    • pp.287-298
    • /
    • 2014
  • 본 연구에서는 TBM 터널 SFRC 세그먼트 개발을 위하여 이형철근이 보강되지 않은 SFRC 보의 휨파괴 실험을 통하여 SFRC 배합의 평가를 수행하였다. 압축강도, 강섬유의 형상비와 강섬유 혼입률을 변수로 하여 총 16개의 SFRC 보를 제작하고 휨에 의하여 파괴시까지 실험하였다. 하중-수직변위 분석결과, 큰 형상비의 강섬유를 사용하여도 소형보의 실험(Moon et al, 2013)과 달리 보의 인성거동을 증진시키는 효과는 거의 없는 것으로 나타났다. 극한상태에서 강섬유는 균열폭 7 mm까지 하중을 저항하는 것으로 확인되었다. 또한, 기존의 SFRC 보의 휨강도예측모델과 실험결과를 비교한 결과, SFRC 보의 휨강도를 최대 20배까지 과소평가하고 있는 것으로 나타났다. 그러나, TR No. 63 모델(Concrete Society, 2011)은 다른 모델에 비하여 근사하게 휨강도를 예측하는 것으로 확인되었다. 강섬유의 분포에 대한 분석결과, 소형보에서 보다 실제 규모의 보에서 강섬유의 분산도가 훨씬 개선되는 것을 확인하였다.

부착되지 않은 텐돈을 갖는 PS 콘크리트 연속부재의 해석적 연구 (Analysis of Prestressed Concrete Continuous Members with Unbonded Tendons)

  • 문정호;이리형
    • 콘크리트학회지
    • /
    • 제7권6호
    • /
    • pp.197-208
    • /
    • 1995
  • 본 연구에서는 부착되지 않은 텐돈을 갖는 PS콘크리트 구조체에 대한 해석적 여구가 진행되었는데 해석결과는 기존의 실험결과들과 비교되었다. 기존의 실험 결과들로부터 하중변위 관계, 구조체의 파괴시 텐돈응력에 대한 설계식, 기존의 보통 철근량의 효과, 부재길이에 대한 부재두께의 효과, 하중의 종류에 따른 영향등을 해석적 연구와 병행하여 분석하였다. 총 12개의 실험결과가 분석되었는데, 그 중 6개는 2스팬 연속보이며, 나머지 6개는 3스팬 연속 슬래브였다. 해석 결과는 실험결과와 잘 일치함을 보여 주었으며, 구조체의 파괴시 텐돈의 응력은 기존의 보통 철근의 효과, 하중의 패턴, 텐돈의 형상 등에 따라 많은 영향을 받는 것으로 나타났다.

와이어로프로 보강된 철근콘크리트 기둥의 휨 거동에 대한 강판 정착의 영향 (Effect of T-Plate Anchorage on the Flexural Behavior of Reinforced Concrete Columns Strengthened with Wire Rope Units)

  • 심재일;양근혁;변항용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.493-494
    • /
    • 2009
  • 와이어로프 유닛으로 보강된 철근콘크리트 기둥의 T형 강판 정착효과를 알아보기 위해 중심축하중과 횡하중을 동시에 받는 3개의 기둥 시험체가 휨 실험되었다. 주요변수는 T형 강판의 정착 유무이다. 실험된 기둥의 연성비는 기존 연구자들의 띠철근의 실험결과와 비교되었다. 실험결과 T형 강판의 정착으로 횡하중 내력 및 연성비는 각각 무보강 기둥에 비해 40%와 130% 향상되었다. 특히, 동일한 유효횡보강지수에서 T형 강판이 정착된 보강기둥의 연성비는 띠철근 기둥에 비해 현저히 높았다.

  • PDF