• Title/Summary/Keyword: flexural compressive strength

Search Result 1,123, Processing Time 0.026 seconds

강섬유보강 콘크리트보의 휨내력 예측식의 제안 (Prediction of Flexural Capacities of Steel-Fiber Reinforced Concrete Beams)

  • 김우석;곽윤근;김주범
    • 콘크리트학회논문집
    • /
    • 제18권3호
    • /
    • pp.361-370
    • /
    • 2006
  • 본 연구에서는 국내외 강섬유보강 콘크리트보의 실험값 및 이론식을 분석하여 강섬유의 보강효과 및 부재의 역학적 거동을 규명하였고, 기존의 휨강도식보다 더 정확하고 합리적인 휨강도식을 제안하였다. 제안된 휨강도식은 실험값과 좋은 일치를 보여주었고, 강섬유보강 콘크리트보의 휨강도식은 강섬유보강효과뿐만 아니라 철근의 변형률 경화효과도 함께 고려하는 것이 적절함을 알 수 있었다.

강섬유 혼입율이 강섬유보강 고강도 콘크리트의 작업성과 강도특성에 미치는 영향 (Influence of Steel Fiber Volume Ratios on Workability and Strength Characteristics of Steel Fiber Reinforced High-Strength Concrete)

  • 김윤일;이양근;김명성
    • 한국건축시공학회지
    • /
    • 제8권3호
    • /
    • pp.75-83
    • /
    • 2008
  • In this paper, concrete material tests were carried out to investigate influence of steel fiber volumn ratios on variations of workability and strength characteristics of steel fiber reinforced high-strength concrete, $50MPa{\sim}90MPa$ of compressive strength, according to increase of fiber volume. Test specimens were arranged with six levels of concrete compressive strength and fiber volumn ratios, 0.0%, 0.5%, 1.0%, 1.5%, 2.0%. The test results showed that steel fiber reinforced high-strength concrete($70MPa{\sim}90MPa$, 1.5% fiber volumn ratio) with good workability of slump 20cm could be used practically and effects of steel fiber reinforcement in improvement of concrete strength and toughness characteristics such as splitting tensile strength, flexural strength, and diagonal tensioned shear strength, were more distinguished in high-strength concrete than general strength concrete. And the test results indicated that splitting tensile strength of fiber reinforced concrete was proportioned to the product of steel fiber volumn ratios, $V_f(%)$ and sqare root of compressive strength, $\sqrt{f_{ck}}$, and the increasing rate was in contrast with that of flexural strength, and increase of diagonal tensioned shear strength was remarkable at steel fiber volumn ratio, 0.5%.

비정질 강섬유와 유기섬유를 이용한 하이브리드 섬유보강 콘크리트의 작업성 및 강도 특성 (Workability and Strength Properties of Hybrid Fiber Reinforced Concrete Using Amorphous Steel Fiber and Organic Fiber)

  • 권순오;배수호;이현진;김진우;이준철
    • 복합신소재구조학회 논문집
    • /
    • 제6권4호
    • /
    • pp.58-63
    • /
    • 2015
  • The purpose of this experimental research is to evaluate the workability and strength properties of hybrid fiber reinforced concrete containing amorphous steel fiber and organic fiber. For this purpose, the hybrid fiber reinforced concrete containing amorphous steel fiber(ASF) with polyamide(PA) and polyvinyl alcohol(PVA) fiber, respectively were made according to their total volume fraction of 0.5% for water-binder ratio of 33%, and then the characteristics such as the workability, compressive strength, and flexural strength of those were investigated. It was observed from the test results that the workability and compressive strength at 7 and 28 days were decreased and the flexural strength at 7 and 28 days was increased with increasing ASF and decreasing organic fiber.

쇄빙연구선 ARAON호를 이용한 북극해 해빙의 재료특성 (2) - 해빙의 압축강도, 굽힘강도 및 결정구조 - (Material Properties of Arctic Sea Ice during 2010 Arctic Voyage of Icebreaking Research Vessel ARAON: Part 2 - Compressive Strength, Flexural Strength, and Crystal Structures)

  • 김대환;박영진;최경식
    • 한국해양공학회지
    • /
    • 제26권1호
    • /
    • pp.1-8
    • /
    • 2012
  • To correctly estimate ice load and ice resistance for a ship's hull, it is essential to understand the material properties of sea ice during ice field trials and to use the proper experimental procedure for gathering ice strength data. The first Korean-made icebreaking research vessel (IBRV), ARAON, had her second sea ice trial in the Arctic Ocean during July and August of 2010. This paper describes the test procedures used to properly obtain sea ice strength data, which provides the basic information on the ship's performance in an ice-covered sea and can be used to estimate the correct ice load and ice resistance on the IBRV ARAON. The data gathered from three sea ice field trials during the Arctic voyage of the ARAON includes the ice compressive strength, flexural strength, and failure strain of sea ice. This paper analyzes the gathered sea ice data in comparison with data from the first voyage of the ARAON during her Antarctic Sea ice trial in January 2010.

Corrosion effects on mechanical behavior of steel fiber reinforced concrete, including fibers from recycled tires

  • Ansari, Mokhtar;Safiey, Amir
    • Computers and Concrete
    • /
    • 제26권4호
    • /
    • pp.367-375
    • /
    • 2020
  • Today, the use of special technologies in the admixture of concrete has made tremendous progress, but the problem that has always existed in the construction of concrete members is the brittleness and lack of loading bearing after cracking, which leads to reduced strength and energy absorption. One of the best ways to fix this is to reinforce the concrete with steel fibers. Steel fibers also control cracks due to dry shrinkage, reduce structural crack width, and improve impact resistance. In this study, recycled steel fibers from worn tires have been used in the manufacture of concrete samples, the secondary benefits of which are the reduction of environmental pollution. One of the disadvantages of steel fiber reinforced concrete is the corrosion of steel fibers and their deterioration in harsh environments such as coastal areas. Corrosion caused by chlorine ions in metal fibers causes deterioration and early decommissioning of structures in corrosive environments. In this study, the effect of the dosage of steel fibers (dosages of 15, 30, and 45 kg of fibers per cubic meter of concrete) and aspect ratio of fibers (aspect ratio of 25 and 50) on compressive and flexural strength of concrete samples are investigated. In the following, the effect of fiber corrosion on the results of the mechanical properties of concrete samples is examined. The results show that the increase in fiber causes a relative increase in compressive strength, and a significant increase in flexural strength, and corrosion of steel fibers without reducing workability reduces compressive strength and flexural strength by up to 6 to 11%, respectively.

Predictive models of hardened mechanical properties of waste LCD glass concrete

  • Wang, Chien-Chih;Wang, Her-Yung;Huang, Chi
    • Computers and Concrete
    • /
    • 제14권5호
    • /
    • pp.577-597
    • /
    • 2014
  • This paper aims to develop a prediction model for the hardened properties of waste LCD glass that is used in concrete by analyzing a series of laboratory test results, which were obtained in our previous study. We also summarized the testing results of the hardened properties of a variety of waste LCD glass concretes and discussed the effect of factors such as the water-binder ratio (w/b), waste glass content (G) and age (t) on the concrete compressive strength, flexural strength and ultrasonic pulse velocity. This study also applied a hyperbolic function, an exponential function and a power function in a non-linear regression analysis of multiple variables and established the prediction model that could consider the effect of the water-binder ratio (w/b), waste glass content (G) and age (t) on the concrete compressive strength, flexural strength and ultrasonic pulse velocity. Compared with the testing results, the statistical analysis shows that the coefficient of determination $R^2$ and the mean absolute percentage error (MAPE) were 0.93-0.96 and 5.4-8.4% for the compressive strength, 0.83-0.89 and 8.9-12.2% for the flexural strength and 0.87-0.89 and 1.8-2.2% for the ultrasonic pulse velocity, respectively. The proposed models are highly accurate in predicting the compressive strength, flexural strength and ultrasonic pulse velocity of waste LCD glass concrete. However, with other ranges of mixture parameters, the predicted models must be further studied.

고강도철근콘크리트 보의 휨강성에 관한 실험적 연구 (An Experimental Study on the Flexural Rigidity of Reinforced High Strength Concrete Beams)

  • 고만영;김상우;김용부
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.71-78
    • /
    • 2000
  • This paper presents a study on the flexural rigidity of reinforced high strength concrete beams. Thirty six beams with different compressive strength of concrete, tensile reinforcement ratio, compressive reinforcement ratio, and pattern of loadings(1 point loading and 2 points loading) were tested to evaluate the effective moment of inertia. According to the experimental results, the eqation(1) proposed by ACI code for the effective moment of inertia overestimated that of simply supported reinforced high strength concrete beams. Thus, in this paper, an empirical equation(3) is proposed as a lower bound of 90% confidence limit to estimate the effective moment of inertia of simply supported reinforced high strength concrete beams.

On the Ductility of High-Strength Concrete Beams

  • Jang, Il-Young;Park, Hoon-Gyu;Kim, Sung-Soo;Kim, Jong-Hoe;Kim, Yong-Gon
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.115-122
    • /
    • 2008
  • Ductility is important in the design of reinforced concrete structures. In seismic design of reinforced concrete members, it is necessary to allow for relatively large ductility so that the seismic energy is absorbed to avoid shear failure or significant degradation of strength even after yielding of reinforcing steels in the concrete member occurs. Therefore, prediction of the ductility should be as accurate as possible. The principal aim of this paper is to present the basic data for the ductility evaluation of reinforced high-strength concrete beams. Accordingly, 23 flexural tests were conducted on full-scale structural concrete beam specimens having concrete compressive strength of 40, 60, and 70MPa. The test results were then reviewed in terms of flexural capacity and ductility. The effect of concrete compressive strength, web reinforcement ratio, tension steel ratio, and shear span to beam depth ratio on ductility were investigated experimentally.

온도에 따른 콘크리트 구조체 단면 보수용 폴리머 모르타르의 기초적 연구 (Fundamental Study of Polymer-modified Cement Mortar for Maintenance in Concrete Structure According to Ambient Temperature)

  • 서정필;김재원;이정구;최훈국;강철;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.59-62
    • /
    • 2007
  • Nowadays, polymer-cement mortars are widely used in construction field(floorings and pavements, water-proofings, adhesives, repair materials, deck coverings, anti-corrosive linings) Because of excellent performance such as high tensile and flexural strength, waterproofness, excellent adhesion, good durability, improved wear and chemical resistances. This article presents the results of experimental study that investigates the effect of ambient temperature on the strength properties of polymer-modified cement mortar. Results show that when increasing the polymer proportion in mortar on different ambient temperature, the compressive strength and flexural strength are decreased, and also alkali resistance is decreased.

  • PDF

슬러리 충전 고성능 섬유 보강 시멘트 복합체의 역학적 성능 (Mechanical Performance of Slurry Infiltrated High Performance Fiber Reinforced Cementitious Composite)

  • 김현욱;이창준
    • 한국건축시공학회지
    • /
    • 제17권2호
    • /
    • pp.167-174
    • /
    • 2017
  • 고비율의 고로슬래그를 사용한 슬러리 충전 고성능 섬유보강 시멘트 복합체(SI-HPFRCC)의 역학적 성능을 평가하였다. SI-HPFRCC 실험체 제작을 위해 hooked-end 형의 강섬유를 6.4% 사용하였다. 재령에 따른 압축강도 및 압축인성과 휨강도 및 휨인성 실험을 통해 SI-HPFRCC의 역학적 성능을 평가하였다. 또한 섬유보강 효과를 평가하기 위해 SI-HPFRCC 실험체 제작에 사용된 슬러리 매트릭스의 압축강도 및 휨강도를 측정하였다. 실험결과 SI-HPFRCC의 휨거동이 재령에 따라 취성이 증가함을 확인하였다. 압축거동의 경우에도 재령에 따른 취성 증가를 볼 수 있었으나 그 정도는 미미하였다. 강도측면에서 볼 때 SI-HPFRCC는 슬러리 매트릭스에 비해 약 140~190%의 압축강도 증가와 440~500%의 휨강도 증가를 보였다.