• Title/Summary/Keyword: flat-plate system

Search Result 344, Processing Time 0.026 seconds

A Study on the Characteristic of Impinging Pressure Distribution in the Three Dimensional Impinging Water Jet (삼차원(三次元) 수분류(水噴流)의 충돌(衝突) 압력(壓力) 분포(分布) 특성(特性)에 관(關)한 연구(硏究))

  • Lee, J.S.;Choi, K.K.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.217-228
    • /
    • 1998
  • The purpose of this research is to investigate the characteristics of static and total pressure distribution in the upward free water jet system impinged on a downward flat plate. The rectangular nozzle was used and its contraction and aspect ratio was five and about seven respectively. Experimental conditions considered were jet velocity, distance between nozzle and flat plate, height of supplementary water. It was founded that pressure distribution on the flat plate had the Gaussian curve when the pressure at stagnation point and impinging half width were chosen as the scaling parameters. The maximum pressure was shown at the stagnation point. The central impingement velocity decreased with the increment of distance between nozzle and flat plate, and its slop of decay was similar to that of chracteristics decay region in the three-dimensional free jet.

  • PDF

Use of Super Elements for Efficient Analysis of Flat Plate Structures (플랫플레이트 구조물의 효율적인 해석을 위한 수퍼요소의 활용)

  • 김현수;이승재;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.4
    • /
    • pp.439-450
    • /
    • 2003
  • Flat plate system has been adopted in many buildings constructed recently because of the advantage of reduced floor heights to meet the economical and architectural demands. Structural engineers commonly use the effective beam width model(EBWM) in practical engineering for the analysis of flat plate structures. However, in many cases, when it is difficult to use the EBWM, it is necessary to use a refined finite element model for an accurate analysis. But it would take significant amount of computational time and memory if the entire building structure was subdivided with finer meshes. An efficient analytical method is proposed in this study to obtain accurate results in significantly reduced computational time. The proposed method employs super elements developed using the matrix condensation technique and fictitious beams are used in the development of super elements to enforce the compatibility at the interfaces of super elements. The stiffness degradation of flat plate system considered in the EBWM was taken into account by reducing the elastic modulus of floor slabs in this study. Static and dynamic analyses of example structures were performed and the efficiency and accuracy of the proposed method were verified by comparing the results with those of the refined finite element model and the EBWM.

A Study on Slamming Impact Pressure by a Numerical Method based on the Cartesian-grid System (직교격자계 기반의 수치계산법을 이용한 슬래밍 충격압력의 연구)

  • Kim, Ki-Yong;Lee, Young-Gill;Ha, Yoon-Jin;Kang, Ui-Ha;Park, Jeong-Ho;Lee, Sun-Kyu;Lee, Chang-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.4
    • /
    • pp.308-315
    • /
    • 2019
  • In this study, numerical simulations of slamming impact pressure acting on the flat plate and wedge type models using the cartesian-grid system and Modified Marker-Density Method (MMD method) were performed and the results were examined. The flat plate and wedge type models were selected as target objects, the turbulence characteristics were considered by applying the Sub-Grid Scale (SGS) turbulence model. Through this study, how the pressure acting on the target objects according to the incident angle influences the slamming impact pressure was examined and the results were compared with the flow characteristics of other experimental results. Also, the degree of slamming impact pressure is evaluated with respect to the cartesian-grid system and MMD method, which is easy to use and has a high degree of calculation for free surface.

Experimental Study on the Film Cooling Effectiveness on a Flat Plate with Anti-Vortex Holes

  • Park, Soon Sang;Park, Jung Shin;Kwak, Jae Su
    • International Journal of Aerospace System Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • In this paper, the effects of the anti-vortex hole angle and blowing ratio on the flat plate film cooling effectiveness were experimentally investigated. For the film cooling effectiveness measurement, pressure sensitive paint technique was applied. The experiments were conducted for cylindrical and anti-vortex film cooling holes, and three blowing ratios of 0.25, 0.5, and 1.0 were tested. Two anti-vortex hole angles of 0 and 15 degree with respect to the flow direction were considered. For the cylindrical hole case, the film cooling effectiveness decreased as the blowing ratio increased because of the coolant lift-off. For the angle anti-vortex hole cases, however, higher blowing ratio resulted in higher film cooling effectiveness due to the reduced actual blowing ratio and diminished kidney vortex. For all blowing ratio, the angled anti-vortex hole case showed the highest film cooling effectiveness.

A Study on the Heat Transfer Enhancement by Trapezoid Rod in Impinging Jet System (충돌분류계에서 사다리형 로드를 이용한 열전달증진에 관한 연구)

  • Lim, T.S.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.565-571
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of air flow and heat transfer caused by trapezoid rods array in impinging air jet system. In this study, trapezoid rods have been set up on front of flat plate to act as a turbulence promoter. Local Nusselt numbers were determined as a function of three parameters: (a) the space from rods to heating surface(C=1, 2, 4mm), (b) the pitch between each rods(P=30, 40, 50mm), (c) the distance from nozzle exit to flat plate(H/B=2, 6, 10). And this research compared the above with the experiment without trapezoid rods. As a result, heat transfer performance was best under the condition of C=1mm and as the pitch is 30mm. In this case, maximum rate of heat transfer augmentation is about 1.9 times greater compared to that without trapezoid rods.

  • PDF

The Study on The Heat Transfer Enhancement Using Wire Mesh in Impinging Jet System (충돌분류계에서 WIRE MESH를 이용한 열전달 증진에 관한 연구)

  • Kum, S.M.;Kim, D.C.;Yoo, J.O.;Lee, C.E.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.47-58
    • /
    • 1997
  • The objective of this research was to investigate the enhancement of heat transfer by wire mesh in impinging air jet system at the potential core region. The first experiment was carried out without mesh between nozzle exit and flat plate and the second experiment was done with mesh between them. When mesh was installed in front of the plate, heat transfer has been Increased due to the acceleration between rectangular halls and divided small jet In case clearances are changed, heat transfer comes to maximum under the condition of C=1mm, irrespective of nozzle exit velocity and H/B. Also the average heat transfer enhancement rate of a flat plate with mesh has been increased about 44% at maximum under the condition of U=18m/s, H/B=2 and C=1mm, compared to the result of a flat plate without mesh.

  • PDF

Performance Estimation of Hybrid Solar Air-Water Heater on Single Working of Heating Medium (복합형 태양열 가열기에서 열매체 단일운전에 따른 기기성능 평가)

  • Choi, Hwi-Ung;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.49-56
    • /
    • 2014
  • Research about hybrid solar air-water heater that can make heated air and hot water was conducted as a part of improving efficiency of solar thermal energy. At this experiment, ability of making heating air and hot water was investigated and compared with traditional solar air heater and flat plate solar collector for hot water when air or liquid was heated respectively. Comparing hybrid solar air-water heater that used in this experiment to other solar air heater studied already, it has a lower efficiency at same mass flow rate. Air channel structure, fin's shape and arrangement in the air channel result in these difference then the ability of air heating need to be improved with changing these thing. In case of making hot water, performance was shown as similar with traditional system although the air channels were established beneath absorbing plate. But the heat loss coefficient was shown higher value by installing of air channel. Also the performance of hot water making was shown lower value at same liquid mass flow rate with traditional flat plate solar collector for hot water. So the necessity of performance improvement at lower mass flow rate of each heating medium can be confirmed.

A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater (복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구)

  • Choi, Hwi-Ung;Rokhman, Fatkhur;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

A Study on Performance of Seasonal Borehole Thermal Energy Storage System Using TRNSYS (TRNSYS를 이용한 Borehole 방식 태양열 계간축열 시스템의 성능에 관한 연구)

  • Park, Sang-Mi;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.37-47
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a glass greenhouse was analyzed numerically. For this study, the gardening 16th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And, the heating load of the glass greenhouse selected was 576 GJ. BTES (Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modeling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump, controller. As a result of the analysis, the energy of 928 GJ from the flat plate solar collector was stored into BTES system and 393 GJ of energy from BTES system was extracted during heating period, so that it was confirmed that the thermal efficiency of BTES system was 42% in 5th year. Also since the heat supplied from the auxiliary boiler was 87 GJ in 5th year, the total annual heating demand was confirmed to be mostly satisfied by the proposed system.